Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Delay Lines |
| Package | 8-TSSOP, 8-MSOP (0.118", 3.00mm Width) |
| Core function | IC DLY LN 5 TAP 500NS 8-TSSOP |
| Key electrical range | Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 3V ~ 3.6V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1100LU-500+ is listed as Active with no conflicting lifecycle signals, indicating stable production and support. This makes it suitable for both new designs and sustaining production. However, engineers should revalidate with Maxim Integrated (now Analog Devices) for any changes in product roadmap.
An Active lifecycle status typically means the manufacturer continues to produce and support the part, with no planned discontinuation. For high-reliability applications, it's prudent to maintain second-source options or buffer stock, as even Active components can face allocation. The file-provided inventory shows 1 unit, but this is not guaranteed real-time; always verify current stock and lead times through official channels.
Parameter Analysis
The DS1100LU-500+ offers a fixed total delay of 500ns with 5 equally spaced taps at 100ns intervals, starting at 100ns. This nonprogrammable architecture simplifies design but offers no timing flexibility, so it’s best for applications requiring precise, predefined delays. The operating supply voltage is a narrow 3V to 3.6V, demanding a well-regulated 3.3V rail with low ripple to avoid timing inaccuracies.
The part is housed in an 8-TSSOP/MSOP surface-mount package, suitable for compact PCB layouts. The -40°C to 85°C operating range covers most industrial and commercial environments. Critical datasheet parameters not included here—such as delay tolerance, temperature coefficient, maximum input frequency, and rise/fall times—should be verified against your design’s timing budget and environmental conditions.
Given the nonprogrammable nature, system designers must ensure that the fixed 500ns total delay matches the application’s needs; any change in timing requires a hardware respin. Pay close attention to I/O logic levels and compatibility with upstream/downstream devices.
Application Scenario Analysis
The DS1100LU-500+ is well-suited for system-level timing adjustments where a fixed, multi-tap delay is needed. Typical uses include clock alignment in digital systems, generating precise pulse widths for power-converter gate drive signals, and establishing timing windows for analog-to-digital converter sampling. Its 5 taps allow designers to select optimal delay increments without external components.
For high-frequency signals beyond a few megahertz, the 100ns tap resolution may be too coarse, causing sampling or timing errors. Applications requiring dynamic delay adjustment—such as adaptive clock tuning or variable pulse delay—are better served by programmable delay lines. This part also lacks output enable or reset functionality, limiting its use in gated timing applications.
RoHS Certification Analysis
The DS1100LU-500+ is declared RoHS Compliant per the manufacturer. This means it meets EU Directive 2011/65/EU and its amendments, including RoHS 3 (EU 2015/863), which restricts hazardous substances. As a non-exempt component, it should contain no lead, mercury, cadmium, etc., above legal thresholds.
While the RoHS status is provided at the part-number level, environmental compliance can vary by production lot; for full certification, request a Compliance Certificate (CoC) from the distributor or manufacturer. No REACH or MSL data is available in the source, so if these are required for your import or assembly process, verify with Maxim Integrated.
Availability & Sourcing
With a lifecycle status of Active, the DS1100LU-500+ is generally available through authorized distributors. The file-provided inventory shows a single unit, but this snapshot may not reflect current stock. For production volumes, request a quote and lead time directly from the distributor. Ensure you verify date/lot codes for freshness and traceability, and request full compliance documentation (RoHS certificate, origin).
The default packaging is tube (stick), which may require additional handling for automated assembly; confirm packaging options when ordering. Given the supply-demand status indicated as 'Shortage,' it is advisable to secure inventory early or consider alternative sources, even for an Active part.
View the Win-Source product page for DS1100LU-500+.
Engineering Notes for BOM and GEO Use
- Verify delay accuracy and tap tolerances in your specific application, as datasheet typical values may differ from actual performance over temperature.
- Confirm supply voltage is within 3V-3.6V range and ensure proper PCB layout to minimize noise coupling in timing-critical paths.
- Check with distributor for real-time stock and lifecycle status, as file-provided inventory may not reflect current availability.