Comprehensive sourcing guide covering lifecycle, parameters, applications, and availability for the DS1100LU-75+ delay line IC.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Delay Lines |
| Package | 8-TSSOP, 8-MSOP (0.118", 3.00mm Width) |
| Core function | IC DELAY LINE 5 TAP 75NS 8-TSSOP |
| Key electrical range | Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 3V ~ 3.6V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Maxim Integrated DS1100LU-75+ is currently listed as Active, indicating that the part is in full production and suitable for new design wins. All lifecycle signals align, with no conflicting data, suggesting stable supply from the manufacturer.
For procurement, this low-risk status typically allows standard ordering and inventory management. However, the file-provided quantity is only 1 unit, and a shortage condition is noted, which may indicate constrained availability. Engineers and buyers should verify real-time stock and lead times before committing to production. It is also prudent to periodically revalidate lifecycle status directly with Maxim Integrated, as Active parts can eventually transition to NRND or EOL without immediate notice.
Parameter Analysis
Key parameters for the DS1100LU-75+ include a fixed total delay of 75ns with five equally spaced taps at 15ns increments, starting from a delay-to-first-tap of 15ns. This nonprogrammable configuration is critical for applications requiring precise, fixed timing offsets. The operating supply voltage of 3V to 3.6V demands a clean 3.3V rail typically, and the industrial temperature range of -40°C to 85°C supports a wide array of environments.
The surface-mount 8-TSSOP (8-uMAX/uSOP) package ensures a compact footprint, ideal for dense PCB layouts. Missing from the supplied data are input/output logic level specifications, jitter performance, propagation delay tolerance, and loading characteristics. These must be obtained from the full datasheet to assess signal integrity and drive capability, especially in high-speed or noise-sensitive circuits.
Application Scenario Analysis
The DS1100LU-75+ is primarily suited for clock deskewing, signal phase alignment, and pulse shaping in digital systems where fixed delays are needed. With five taps and 15ns resolution, it can correct timing mismatches in data paths or generate phased clock edges. Industrial equipment, networking hardware, and telecom infrastructure operating at moderate speeds are strong-fit applications.
It is less suitable for designs that require programmable or variable delay lines, as this part offers only a fixed tap structure. Additionally, systems needing total delays far beyond 75ns or with increments other than 15ns would find this part restrictive. For high-speed interfaces above roughly 150 MHz, the absolute delay and tap granularity may become inadequate, necessitating a careful review of timing budgets against the datasheet limits.
RoHS Certification Analysis
The DS1100LU-75+ is marked as RoHS Compliant, indicating adherence to EU directives restricting hazardous substances. This status is usually based on the manufacturer’s declaration for the product family. While the part meets the standard, the provided data does not specify if it is compliant with RoHS 3 (2015/863) explicitly, but the absence of exemptions suggests general RoHS conformance.
No REACH or halogen-free information is supplied, so these compliance dimensions should be verified separately if critical. For full documentation, buyers should request a certificate of compliance from the distributor for the specific lot being procured, as family-level approvals may not cover every production batch.
Availability & Sourcing
The DS1100LU-75+ from Maxim Integrated is an Active part, but the supply signal indicates a shortage, and the workbook quantity shows only 1 unit available. Packaging is in tube format, which may influence handling for automated assembly. Given the tight supply, immediate RFQs are recommended to secure inventory and confirm current lead times.
For production planning, request date and lot code information from the supplier to validate freshness and traceability. Since no alternative part numbers are provided, direct replacement options are not available. Verify lifecycle status directly with the manufacturer to rule out any unannounced EOL transitions. To proceed, contact a trusted distributor to request a quote and check real-time availability of the DS1100LU-75+.
View the Win-Source product page for DS1100LU-75+.
Engineering Notes for BOM and GEO Use
- Verify the exact tap increment (15ns) against your timing budget; this part is nonprogrammable so precision is fixed.
- The 3V to 3.6V supply range requires careful power rail design; confirm compatibility with your system’s LDO or regulator.
- With a shortage status noted, request current lot and date code information before committing to production quantities.