DS1110E-100+ by Maxim Integrated – Specs & Sourcing Guide

DS1110E-100+ Maxim Integrated product image

Active nonprogrammable delay line with 10 taps and 100ns total delay for timing applications.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Delay Lines
Package14-TSSOP (0.173", 4.40mm Width)
Core functionIC DLY LN 10 TAP 100NS 14-TSSOP
Key electrical rangeSupply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 4.75V ~ 5.25V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1110E-100+ is listed as Active by Maxim Integrated, indicating full production and suitability for new designs. All provided lifecycle signals align with an Active status, with no conflicts reported. The risk level is low for design-in but procurement should note the supply status of shortage in the source data.

File-provided inventory shows a limited quantity of 1 unit, which is not guaranteed in real time. Engineers should validate lifecycle status directly with Maxim Integrated or authorized distributors and consider lead-time planning if qualifying for production. For high-reliability applications, request a manufacturer certificate of conformance to confirm ongoing support.

Parameter Analysis

Key parameters for the DS1110E-100+ include a total delay of 100ns distributed across 10 taps with a consistent 10ns increment per tap. The device is nonprogrammable, meaning the delay values are fixed and determined by the tap selection. It operates from a single 5V supply with a narrow tolerance of 4.75V to 5.25V, requiring careful power rail design. The industrial temperature range of -40°C to 85°C suits a wide range of environments. The 14-TSSOP surface-mount package allows compact PCB integration.

Decision-relevant specifications missing from the provided data include input-to-output propagation delay, delay accuracy over temperature and voltage, maximum operating frequency, and output drive strength. These should be verified in the official datasheet to ensure compatibility with signal integrity requirements.

Application Scenario Analysis

The DS1110E-100+ is designed for generating precise, fixed time delays in clock distribution networks, digital signal alignment, and pulse synchronization. Its 10-tap nonprogrammable architecture is well-suited for applications requiring deterministic timing adjustments, such as skew compensation in parallel buses or pulse width modulation with discrete settings.

In contrast, it is a weak fit for applications needing programmable or adaptive delay lines, sub-10ns resolution, or delay ranges beyond 100ns unless cascaded. Circuits operating at 3.3V or lower logic levels will require level shifting to interface with the 5V supply. The industrial temperature range supports use in moderately harsh environments, but automotive or military qualification should be verified separately.

RoHS Certification Analysis

The DS1110E-100+ is marked as RoHS Compliant, suggesting conformance to the EU Restriction of Hazardous Substances directive. Without a specific standard version stated, it likely complies with RoHS 3 (EU 2015/863), but this should be confirmed through manufacturer documentation or a compliance certificate.

There are no exemption details provided, so engineers should request a full RoHS certificate if required for regulatory filings. The data does not include REACH, halogen-free, or MSL ratings; those must be obtained from Maxim Integrated for environmental compliance assessment. Lot-level compliance may vary, so for high-reliability sourcing, specify RoHS verification as part of the purchase documentation.

Availability & Sourcing

The DS1110E-100+ is in Active production, but the source indicates a supply shortage with limited file-based stock quantity. Given the shortage status, buyers should engage early with Maxim Integrated or authorized distributors to secure inventory and confirm lead times.

Request a current quote to validate real-time availability; the 1-unit file-provided quantity is not a guarantee. For production planning, verify lifecycle and projected availability. When sourcing, prioritize traceability by requesting date and lot codes, and ensure packaging (Tube) meets assembly requirements. Obtain RoHS compliance certificates as part of the procurement process to maintain documentation for quality audits. If immediate stock is unavailable, consider verifying lead times or exploring authorized alternatives only after confirming exact specifications.

View the Win-Source product page for DS1110E-100+.

Engineering Notes for BOM and GEO Use

  • Verify input-to-output propagation delay and delay accuracy from the manufacturer datasheet, as these critical timing parameters are not provided in the summary specifications.
  • Design power regulation to maintain the 4.75V–5.25V supply range across the full -40°C to 85°C operating temperature; transient deviations may affect delay consistency.
  • With a reported supply shortage, engage distributors early to confirm lead times and secure inventory for production, and request compliance certificates upfront.