Active 10-tap nonprogrammable delay line with 100ns total delay in 16-SOIC package from Maxim Integrated.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Delay Lines |
| Package | 16-SOIC (0.295", 7.50mm Width) |
| Core function | IC DLY LN 10 TAP 100NS 16-SOIC |
| Key electrical range | Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 4.75V ~ 5.25V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1110S-100+ from Maxim Integrated is currently listed as Active. This lifecycle status indicates the component is in full production and supported by the manufacturer for both new designs and ongoing production. Engineers can confidently use the DS1110S-100+ in new PCB designs without near-term risk of discontinuation, though standard qualification procedures should still be followed. For existing designs, continued sourcing remains stable. No lifecycle conflicts are present across the supplied data sources.
However, procurement teams should note that lifecycle declarations are point-in-time and should be re-validated directly with Maxim Integrated or authorized distributors, especially before committing to high-volume production. The file-provided inventory shows 1 unit on hand, but this is a snapshot and not a guarantee of real-time availability. Always confirm current stock and factory lead times through official channels.
Parameter Analysis
The DS1110S-100+ is a 10-tap nonprogrammable delay line providing a fixed total delay of 100 nanoseconds, with each tap incrementing by 10 ns from the first tap delay of 10 ns. This granularity is well-suited for clock phase adjustment and pulse timing in digital systems. The device operates from a 4.75V to 5.25V supply, which restricts it to 5V logic domains; designers must ensure system voltage compatibility, as 3.3V operation is unsupported. The specified temperature range of -40°C to 85°C covers industrial applications, but thermal derating near the upper limit may require margin analysis.
The nonprogrammable function means delay values are fixed at manufacturing; thus, precise application timing must align with the 10 ns steps. The 16-SOIC surface-mount package with 0.295-inch width is easy to integrate into standard PCB layouts, but observe pad dimensions for automated assembly. Critical missing parameters include maximum input frequency, output rise/fall times, and tap-to-tap skew, which should be obtained from the full Maxim Integrated datasheet to validate signal integrity in high-speed designs.
Application Scenario Analysis
The DS1110S-100+ excels in applications requiring fixed, repeatable delay steps for clock distribution networks, such as synchronizing data paths in FPGAs or microprocessors where 10 ns incremental adjustment is sufficient. It is also useful for generating pulse-width-modulated signals or compensating for PCB trace length differences in high-speed digital designs. Industrial temperature range makes it suitable for factory automation and test equipment.
However, this part is not ideal for systems that demand variable delay under software control, as it lacks programmability. Designs requiring sub-10 ns resolution or multi-voltage operation (e.g., 3.3V) would need an alternative device. The limited supply voltage range also excludes portable or battery-powered applications. Verify that the maximum toggle rate meets your clock frequency; if the datasheet confirms operation up to several megahertz, it may serve well in moderate-speed logic.
RoHS Certification Analysis
The DS1110S-100+ is classified as RoHS Compliant according to the supplier data. This indicates that the component meets the requirements of RoHS 3 (EU 2015/863) for hazardous substance restrictions, including lead-free termination finishes. No explicit exemptions are cited, but typical exemptions for lead in glass of electronic components may apply; consult the manufacturer's certificate for details. REACH compliance information is not provided in the available data, but REACH is a separate regulation and does not substitute for RoHS.
Procurement teams should request a full material declaration or compliance certificate from Maxim Integrated or their distributor when ordering, as RoHS status can vary by product lot and manufacturing date. The package material is not specified as halogen-free, so if halogen-free requirements exist, additional verification is recommended. MSL (moisture sensitivity level) rating is not listed, which may affect storage and reflow profiles; refer to the datasheet or label upon receipt.
Availability & Sourcing
The DS1110S-100+ is supplied in tube packaging for the 16-SOIC package, which facilitates manual or automated pick-and-place. As an Active part, standard procurement channels should provide ready access, but the current supply and demand status is noted as Shortage. The file-provided inventory indicates 1 unit, but this figure is not a live stock guarantee and must be confirmed via quote. Buyers should request a formal quotation through Win Source or authorized distributors to secure current availability and lead times.
Given the volatile component market, engineers should plan for possible extended lead times despite the Active lifecycle. Request date/lot code traceability and full compliance documentation (RoHS, REACH, and MSL if needed) with each order. For high-volume production, consider second-sourcing options or buffer stock to mitigate risk. Contact your supplier to verify the lifecycle is still Active at the time of order, as manufacturer status can change.
View the Win-Source product page for DS1110S-100+.
Engineering Notes for BOM and GEO Use
- Verify supply voltage tolerance (4.75V–5.25V) against system rail; avoid 3.3V operation.
- Confirm maximum operating frequency and timing accuracy from full datasheet for clock distribution designs.
- For new designs, ensure active lifecycle with manufacturer; stock is limited so plan for lead times.