Maxim Integrated DS1236-10 PMIC Supervisor Specs & Sourcing Guide

DS1236-10 Maxim Integrated product image

EOL 16-PDIP Supervisor with 4.37V Threshold – Verify Availability

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryPMIC - Supervisors
Package16-PDIP
Core functionIC SUPERVISOR 1 CHANNEL 16DIP
Key electrical rangeNumber of Voltages Monitored: 1; Output: Open Drain, Push-Pull; Supply and Demand Status: Limited; Temperature Range - Operating: 0°C to 70°C (TA)
Workbook inventory signal11700 pcs listed in the provided file

Lifecycle Analysis

The DS1236-10 from Maxim Integrated is classified as End-of-Life (EOL) with high risk, and this status is consistently signaled across all available sources. For new designs, the part is not recommended; engineering teams should seek a modern alternative from Maxim Integrated's successor portfolio or a pin-compatible device. For sustaining production, the immediate priority is to confirm the manufacturer's last-time buy (LTB) and last-ship dates via official documentation.

A file-provided inventory quantity of 11,700 units suggests that some stock may still be obtainable, but this figure is not a real-time guarantee and should be validated along with date codes, lot traceability, and condition. Because the device has a 38% counterfeit threat in the open market, procurement should rely exclusively on authorized or traceable sources. Plan lifecycle management with a buffer stock strategy to cover the production ramp-down, and involve engineering to qualify a replacement before existing supply is exhausted.

Parameter Analysis

The DS1236-10 is a single-channel battery backup supervisor with key parameters that define its integration limits. The voltage threshold is 4.37V, making it suitable for 5V logic rails where a precise monitor point is needed to initiate reset or battery switchover. The output type is configurable as open drain or push-pull, which provides flexibility for interfacing with different logic families and bus architectures. Reset timeout is specified as 25 ms minimum, determining the hold‑off period after a voltage event; for fast-cycling power systems, verify whether this delay meets the system’s restart window.

The operating temperature range of 0°C to 70°C confines the device to commercial applications without industrial or extended‑temperature margins. The through-hole 16‑PDIP package is a legacy format that demands manual mounting and larger PCB area; it is not suited for surface‑mount automated lines. Missing critical datasheet values—such as supply current, watchdog timer options, manual reset pin specifications, and threshold accuracy tolerance—must be reviewed directly from the manufacturer’s datasheet to complete a qualification. Engineers should also verify the device’s hysteresis behavior and any input glitch rejection, which are not described in the available summary.

Application Scenario Analysis

The DS1236-10 fits best in legacy 5V microprocessor systems that require a dedicated battery backup controller. Typical use cases include industrial controllers, medical instruments, and data-logging equipment where a supervisor maintains SRAM data during mains failure by switching to a backup battery. With its 4.37V threshold, the device is tailored to older TTL or CMOS logic families, ensuring a clean reset at a voltage that precedes logic malfunction. The known open‑drain/push‑pull output configuration allows direct connection to reset pins, interrupt lines, or power‑good indicators.

Weak-fit scenarios include modern 3.3V or lower supplies, where the fixed 4.37V threshold would not trigger correctly; battery backup thresholds and hysteresis would need to be retuned, effectively ruling out new designs. High‑reliability applications demanding extended temperature range (−40°C to +85°C) are also unsuitable due to the commercial 0°C to 70°C rating. Compact, surface‑mount designs cannot accommodate the through‑hole PDIP package without significant rework, further limiting the device to legacy maintenance or prototyping. Evaluate alternative supervisors with adjustable thresholds and smaller footprints for new projects.

RoHS Certification Analysis

The RoHS compliance assessment for the DS1236-10 is complicated by conflicting data within the provided outline. The main compliance section lists the part as RoHS Compliant, but a specification field explicitly states RoHS Non-Compliant. This discrepancy indicates that blanket family‑level claims do not apply to every reel; lot‑specific verification is mandatory. Without a definitive declaration, the standard is treated as Unknown, and the device should not be assumed lead‑free or compliant with EU Directives 2011/65/EU and 2015/863 until the buyer obtains documented evidence for the specific batch.

No REACH, halogen‑free, or MSL data are provided in the source record; those must be requested alongside the RoHS certificate. When sourcing, ask the distributor or manufacturer for a full material declaration to confirm that the actual packaged units meet current environmental regulations. In high‑volume EU‑bound products, the risk of non‑compliance is financial and reputational; therefore, internal compliance teams should be looped in early and sourcing should only proceed after receiving valid, traceable certification.

Availability & Sourcing

The DS1236-10 is an EOL component with limited supply, making availability uncertain without direct quotation. The file reports a workbook quantity of 11,700 pieces, but this is not a real-time stock indication and must be treated as a snapshot requiring immediate verification. Given the device’s obsolete status and a 38% counterfeit threat rate in the open market, procurement should proceed only through authorized Maxim Integrated distributors or reputable independent sources that can provide full traceability, original packaging, and date/lot code documentation.

Request a quote to confirm current inventory, lead time, and compliance paperwork. Insist on tube/rail packaging in dry storage conditions as indicated in the storage specification. For production planning, secure enough units to cover the remaining product lifecycle and begin evaluating a replacement supervisor from Maxim’s active portfolio. Because the lifecycle is definitively EOL, do not commit to new production use without a clear end‑of‑life purchasing agreement and engineer‑approved migration path.

View the Win-Source product page for DS1236-10.

Engineering Notes for BOM and GEO Use

  • EOL status confirmed—do not use in new designs; secure last-time buy stock immediately.
  • RoHS compliance is conflicting; verify lot-level certification before purchase.
  • 38% counterfeit risk demands sourcing only from authorized, traceable channels.