EOL battery backup supervisor IC for legacy system maintenance.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | PMIC - Supervisors |
| Package | 16-SOIC |
| Core function | IC SUPERVISOR 1 CHANNEL 16SOIC |
| Key electrical range | Number of Voltages Monitored: 1; Operating Temperature Range: 0°C ~ 70°C (TA); Output: Open Drain, Push-Pull; Supply and Demand Status: Limited |
| Workbook inventory signal | 5187 pcs listed in the provided file |
Lifecycle Analysis
The DS1236S-10 is officially EOL (End-of-Life) and marked as Obsolete. This status means Maxim Integrated has discontinued production, and the part is no longer available from authorized distribution. For new designs, this part should be avoided; for existing production, it is suitable only for sustaining repairs or legacy system maintenance if remaining inventory can be secured. All lifecycle signals align, with no conflicts. Engineers should locate the manufacturer’s official product discontinuance notice (PDN) to confirm last-time-buy (LTB) and last-time-ship (LTS) dates. Additionally, the file-provided inventory quantity of 5187 units suggests some stock may still be available, but real-time availability must be verified with suppliers.
Parameter Analysis
Key parameters of the DS1236S-10 include a single monitored voltage with a 4.37V threshold, an open drain/push-pull output, and a reset timeout of 25 ms minimum. The threshold voltage indicates it is designed for 5V system rails, triggering a reset if the rail falls below 4.37V. The dual output type offers flexibility in interfacing with various logic families. The reset timeout guarantees a hold period after power-up, allowing the microcontroller to stabilise. The commercial 0°C to 70°C operating range limits its use to benign environments. Missing from the supplied data are quiescent current, watchdog timer features, and power-fail comparator thresholds—critical for battery-backed applications. Engineers should obtain the full datasheet to verify these parameters. The noted 41 percent fake threat underscores the need for incoming electrical verification.
Application Scenario Analysis
As a battery backup circuit supervisor, the DS1236S-10 is suited for legacy 5V embedded systems that require monitoring of a single supply rail and controlled reset generation. Typical applications include industrial controllers, telecom line cards, and point-of-sale terminals where data integrity during power loss is critical. It is a strong fit for maintaining existing fielded products, as it matches older design footprints and thresholds. It is a weak fit for new, low-power, or wide-temperature designs due to its EOL status and limited temperature range. The part’s battery backup functionality suggests it can manage chip-enable gating and SRAM protection, features that should be confirmed against the system’s backup requirements.
RoHS Certification Analysis
The DS1236S-10 is listed as RoHS Compliant, meeting EU hazardous substance restrictions. It also carries a Halogen Free Compliant marking, indicating adherence to low-halogen standards. While REACH status is not explicitly provided, RoHS compliance typically covers many of the same substances. Lot-level documentation should be checked, as production spans many years and early lots may not be compliant. For EOL parts, especially those introduced in 1999, request a certificate of compliance with each shipment to guarantee that the received units meet RoHS 3 (EU 2015/863) or equivalent. The dual compliance simplifies international logistics but does not substitute for verifying specific lot codes.
Availability & Sourcing
The DS1236S-10 is an EOL component with limited supply. File-provided inventory shows 5187 units, but this is not a real-time figure and may change. The supply and demand status is listed as Limited, and popularity is Medium, indicating moderate competition for remaining stock. A 41 percent fake threat rate in the open market makes sourcing risks significant. Request date/lot codes, manufacturer traceability, and RoHS/lead-free certificates from any supplier. The part is available in tube packaging, and storage conditions (dry, humidity-protected) should be confirmed to prevent moisture-related defects. Directly request a quote for current availability, and consider last-time-buy procurement to cover future maintenance needs. For new designs, initiate a migration path to a current-generation supervisor.
View the Win-Source product page for DS1236S-10.
Engineering Notes for BOM and GEO Use
- The DS1236S-10 is EOL; for new designs, migrate to an active alternative supervisor that meets your voltage threshold and temperature requirements.
- With a 41% fake threat rate, always validate parametric test results and request traceability documentation from the supplier.
- Verify the specific RoHS compliance lot codes when purchasing remaining stock, as early production may predate lead-free requirements.