Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Real Time Clocks |
| Package | 8-SO |
| Core function | IC RTC CLK/CALENDAR SER 8SOIC |
| Key electrical range | Current - Timekeeping (Max): 0.3μA to 1μA @ 2V to 5V; Supply and Demand Status: Balance; Supply Voltage - Operating: 2 V to 5.5 V; Temperature Range - Operating: 0°C to 70°C |
| Workbook inventory signal | 10000 pcs listed in the provided file |
Lifecycle Analysis
The Maxim DS1302S+ is listed as Active with a low risk level, indicating ongoing production and full manufacturer support. For new designs, this status suggests the part is suitable for incorporation without immediate risk of discontinuation. However, engineers should still reference Maxim Integrated’s official product lifecycle notifications and PCN alerts to stay informed of any changes. The DS1302S+ has appeared in long-running designs, and its active status reflects continued demand in clock/calendar applications.
File-provided inventory data shows approximately 10000 units, but this is not a real-time figure and should be verified through a quote request. In sustaining production, the part’s active lifecycle supports procurement planning, but for high-volume commitments, buyers should confirm lot availability and lead times directly with authorized sources. All lifecycle signals in the provided data align, reducing uncertainty, but regular revalidation is recommended.
Parameter Analysis
Key parameters of the DS1302S+ include a supply voltage range of 2V to 5.5V, timekeeping current as low as 0.3µA, 31 bytes of NVSRAM, and a 3-wire serial interface. The wide supply voltage range allows the part to operate in 3.3V and 5V systems without level shifting, simplifying power supply design. The extremely low timekeeping current is critical for battery-backed applications, but engineers should note the maximum of 1µA at higher voltages and select a battery with appropriate capacity.
The 31-byte NVSRAM provides non-volatile storage for configuration or data, while the trickle-charger feature requires careful selection of the charging resistor to match the battery chemistry, as described in the datasheet. The date format YY-MM-DD-dd and leap year compensation indicate full calendar functionality. Operating temperature is specified from 0°C to 70°C, which suits commercial/industrial indoor environments but not extended temperature ranges. Missing parameters that should be verified include clock accuracy (ppm), interface timing details, and ESD ratings. Designers must also confirm the exact package dimensions from the manufacturer’s datasheet, as the listing mentions both 8-SO and 8-SOIC.
Application Scenario Analysis
The DS1302S+ is well-suited for applications requiring low-power timekeeping with battery backup, such as embedded systems, data loggers, utility meters, and industrial controllers. Its 3-wire serial interface and NVSRAM are valuable in designs with limited I/O pins that need to retain small amounts of data during power loss. The trickle-charger feature is beneficial in systems using rechargeable backup batteries, like smart sensors or point-of-sale terminals.
However, the 0°C to 70°C operating range makes it less appropriate for outdoor or automotive applications that demand extended temperature grades. The part’s 31-byte memory may be insufficient for log-intensive tasks, and the serial interface may limit speed in high-throughput systems. Overall, the DS1302S+ is a strong fit for standard commercial and light industrial designs, but not for extreme environments or high-speed data transfer applications.
RoHS Certification Analysis
The DS1302S+ is listed as RoHS Compliant, confirming that it meets the requirements of the EU RoHS directive (likely RoHS 3, 2015/863). This compliance means the part does not contain restricted substances such as lead, mercury, or cadmium above the legal thresholds. However, the data does not include REACH or halogen-free declarations; REACH compliance is separate and should be verified if required.
The RoHS compliance is typically a family-level certification for Maxim Integrated, so while the standard product is compliant, specific production lots should be confirmed, especially for high-reliability applications. Buyers can request a certificate of compliance (CoC) when ordering the DS1302S+. No exemptions are noted, suggesting the part is fully compliant across its homogeneous materials. For procurement in regulated markets, this compliance is essential, but it does not substitute for full material declaration documentation if needed for end-product certification.
Availability & Sourcing
The DS1302S+ is an active, high-popularity part with a supply-demand status described as balanced. File-provided stock quantity of 10000 units suggests distributor availability, but current inventory must be confirmed via an RFQ. The device is packaged in reel (TR) format, appropriate for automated assembly. Buyers should verify traceability, date and lot codes, and compliance documentation (RoHS CoC) when sourcing.
A 38% fake threat indicator highlights the risk of counterfeit components in the open market; thus, purchasing from authorized Maxim Integrated distributors or reputable sources is strongly recommended. Lifecycle verification, though currently active, should be rechecked before committing to new production volumes. For active parts, the recommended action is to request a quote for pricing and lead time, and ensure all necessary compliance paperwork accompanies the shipment. Packaging and storage conditions, such as dry storage, are important for SMD devices to prevent moisture-related defects.
View the Win-Source product page for DS1302S+.
Engineering Notes for BOM and GEO Use
- The DS1302S+’s trickle-charge feature requires selection of an appropriate charge resistor to match the battery chemistry and capacity.
- With timekeeping current as low as 0.3µA, the DS1302S+ enables long battery life in backup mode, but designers should verify with worst-case temperature and voltage.
- Despite an active lifecycle status, monitor supply chain for counterfeit risks given a 38% fake threat indicator; source from authorized distributors.