Specs, Lifecycle & Sourcing Information
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Real Time Clocks |
| Package | 24-TSSOP |
| Core function | IC RTC ELAPSED CNT PAR 24TSSOP |
| Key electrical range | Current - Timekeeping (Maximum): 150μA @ 3V ~ 3.6V; Operating Supply Voltage: 3 V ~ 3.6 V; Operating Temperature Range: -40°C ~ 85°C; Supply and Demand Status: Limited |
| Workbook inventory signal | 1400 pcs listed in the provided file |
Lifecycle Analysis
The DS1318E+ is currently listed as Active in Maxim Integrated’s lifecycle database, and all provided lifecycle signals align with this status. However, an Estimated EOL Date of 2024 appears in the supplied data, which creates ambiguity for long-term design planning. Engineers evaluating this part for new designs should contact Analog Devices (which now includes Maxim) to confirm whether a discontinuance notice has been issued or is imminent. Without manufacturer confirmation, treating the part as having a medium risk for new designs is prudent.
For sustaining production, the Active status suggests continued availability, but the 2024 EOL estimate implies that migration planning may be advisable. The file-based inventory indicates 1400 units available through distribution, though this figure is not a real-time guarantee. Designers should verify current stock levels and lead times directly with suppliers.
Parameter Analysis
The DS1318E+ is an elapsed time counter distinct from standard calendar-based RTCs, providing timekeeping in binary format via a parallel interface. Its operating supply voltage of 3V to 3.6V and battery backup voltage of 1.6V to 3.7V allow flexible power design, with a maximum timekeeping current draw of 150µA—helpful for battery-backed applications. The parallel interface demands more I/O lines than serial alternatives but may reduce software overhead in systems with available bus ports.
The -40°C to +85°C industrial temperature range suits embedded equipment, and the 24-TSSOP SMD package fits standard PCB assembly. Features such as an alarm and square wave output enable event-triggered wake-ups or periodic interrupts. Key datasheet parameters not present in the supplier data that should be verified include timing accuracy (ppm), byte-wide register map details, and alarm polarity options. These are critical for determining precise timekeeping performance and system integration.
Application Scenario Analysis
As an elapsed time counter, the DS1318E+ is well-suited for applications that require monitoring of cumulative runtime, such as industrial equipment maintenance logs, warranty tracking, and usage meters. Its ability to preserve count during power loss via a backup battery makes it reliable for embedded systems that must retain data across outages. The parallel interface can be advantageous in older microcontroller architectures that directly map external memory or I/O.
However, this part is not a full real-time clock with calendar and alarm to the second; it provides binary elapsed time, so systems needing human-readable time stamps must implement conversion. It may be less suitable for consumer electronics that prioritize small footprint and serial bus connectivity. The 52% fake threat rate also demands careful sourcing for applications in safety-critical or high-reliability sectors.
RoHS Certification Analysis
The DS1318E+ is declared RoHS Compliant in the supplied data, indicating conformity to EU Directive 2011/65/EU and its amendments regarding hazardous substances. Additionally, it is listed as Halogen Free compliant, which meets industry demands for low halogen content. These certifications are typically valid at the family lot level, but engineers requiring full material declaration should request a certificate from the manufacturer.
No REACH compliance information is provided; however, REACH is a separate regulation and does not substitute for RoHS. If compliance with REACH SVHC is necessary, verify with Analog Devices. The part’s 24-TSSOP plastic package and SMD assembly are compatible with standard lead-free reflow profiles, but actual MSL (moisture sensitivity level) is not specified and should be confirmed from the datasheet before setting storage and baking procedures.
Availability & Sourcing
The DS1318E+ is actively manufactured, but the 2024 estimated EOL date and limited supply and demand status (as reported) necessitate proactive sourcing. A file-based inventory of 1400 units is mentioned, yet this is not a real-time guarantee; buyers should request a quote to confirm current stock and lead times. Given the 52% fake threat on the open market, traceability is paramount. Insist on full lot code and date code traceability, along with manufacturer compliance documentation (RoHS, halogen-free) from authorized channels.
Because the lifecycle signal includes an ambiguous EOL estimate, treat this part as having elevated sourcing risk. For new production designs, verify lifecycle directly with Analog Devices/Maxim before committing. For existing production, secure sufficient buffer stock and consider migrating to a successor if the EOL date is confirmed. Standard packaging is tube for the 24-TSSOP; request specific packaging details and storage conditions (dry pack) when ordering.
View the Win-Source product page for DS1318E+.
Engineering Notes for BOM and GEO Use
- Verify with Maxim/Analog Devices whether the 2024 estimated EOL impacts long-term production plans, despite current Active lifecycle status.
- The parallel interface and 150µA timekeeping current suit embedded systems requiring direct bus connectivity; consider this when evaluating layout complexity.
- Fake threat level on open market is 52%; source only through authorized distributors or request traceability documentation when procuring excess inventory.