DS1390U-18+ Real-Time Clock from Maxim Integrated – Specs & Sourcing Guide

DS1390U-18+ Maxim Integrated product image

Active Maxim Integrated RTC in 10-uMAX package with SPI interface and trickle charger.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Real Time Clocks
Package10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Core functionIC RTC CLK/CALENDAR SPI 10UMAX
Key electrical rangeCurrent - Timekeeping (Max): 100µA @ 1.71V ~ 1.89V; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 1.71V ~ 1.89V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1390U-18+ from Maxim Integrated is an Active product with no conflicting lifecycle signals. This status confirms ongoing production and full manufacturer support, making it suitable for both new designs and sustaining production. Engineers can confidently evaluate this part without immediate risk of discontinuation.

For procurement planning, the Active lifecycle reduces supply chain risk. However, always revalidate status with Maxim Integrated or authorized distributors before committing to high-volume production, as lifecycle statuses can change. Documentation such as product change notifications (PCNs) should be monitored.

The provided inventory signal shows a workbook quantity of 1 unit. This value is file-provided and not a real-time stock level. Obtain current availability and lead times through a request for quote, especially given the Shortage supply and demand status noted in the data.

Parameter Analysis

The DS1390U-18+ operates with a supply voltage between 1.71V and 1.89V, demanding a tight voltage rail. Its max timekeeping current is 100µA within that range, which directly impacts battery backup sizing. The battery backup voltage range of 1.3V to 3.7V offers flexibility for capacitor or coin cell backup solutions.

The SPI interface ensures fast communication with microcontrollers, while integrated features like alarm, leap year, and programmable square wave output reduce external component count. The -40°C to +85°C operating range qualifies it for industrial environments.

Key missing datasheet parameters to verify include clock accuracy (ppm variation over temperature), crystal selection requirements, and I/O voltage tolerance. The 10-uMAX package is compact but requires careful PCB layout for minimal signal traces.

Application Scenario Analysis

The DS1390U-18+ excels in embedded systems requiring a real-time clock with SPI communication and battery-backed timekeeping. Typical applications include industrial automation, utility meters, and portable medical devices where the device can maintain time during power loss using the trickle charger for a supercapacitor or coin cell.

The narrow supply voltage and surface-mount package integrate well into low-voltage digital boards. However, for designs operating outside the 1.71V–1.89V range or needing I2C, this part is not suitable. High-vibration environments may require additional mechanical testing beyond the standard MSOP package.

RoHS Certification Analysis

The DS1390U-18+ is marked RoHS Compliant, indicating conformance to the latest EU RoHS directive (likely RoHS 3, 2015/863). This certification covers restricted substances including lead, mercury, and cadmium, enabling use in RoHS-regulated markets.

While no exemptions are listed, the compliance statement is typically at the part number level. For high-reliability or regulated industries, request lot-specific RoHS certificates from the distributor to ensure traceability. REACH compliance is not provided, so if REACH is required, verify separately.

Availability & Sourcing

Sourcing the DS1390U-18+ requires verifying real-time inventory due to the Shortage supply status indicated. The file shows a workbook quantity of 1 unit, but this is not a guaranteed stock level. Use a request-for-quote process to obtain current availability, lead times, and pricing from authorized distributors.

Ensure you specify the full part number with package suffix and request date/lot code traceability for quality assurance. The standard packaging is Tube, suitable for prototype or medium-volume production. Given the Active lifecycle, standard procurement practices apply, but the shortage flag suggests confirming lead times before design lock-in.

Always recheck lifecycle status and request compliance documentation such as RoHS certificates when placing orders to avoid production delays.

View the Win-Source product page for DS1390U-18+.

Engineering Notes for BOM and GEO Use

  • Verify timekeeping current (100µA max) against battery life requirements for backup mode.
  • Confirm the 1.71V–1.89V supply voltage is compatible with your system's power rail tolerance.
  • Check the operating temperature range (-40°C to +85°C) for industrial or outdoor applications.