DS14C335MSAX by Texas Instruments: Specs & Sourcing Guide

DS14C335MSAX Texas Instruments product image

EOL RS-232 transceiver with 3 drivers/5 receivers, 128Kbps data rate, 28-SSOP package. Verify availability and compliance before design.

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategoryInterface - Drivers, Receivers, Transceivers
Package28-SSOP
Core functionIC TRANSCEIVER FULL 3/5 28SSOP
Key electrical rangeSupply and Demand Status: Balance; Supply Voltage - Operating: 3 V to 3.6 V; Temperature Range - Operating: 0°C to 70°C
Workbook inventory signal7000 pcs listed in the provided file

Lifecycle Analysis

The DS14C335MSAX has reached end-of-life (EOL), meaning it is no longer recommended for new designs. OEMs should treat this as a high-risk component and immediately secure inventory for ongoing production needs. Lifecycle data from Texas Instruments and distributor sources align on EOL status, so the part will not be replenished after existing stock depletes.

For sustaining programs, a last-time buy should be coordinated with authorized suppliers. Engineers must also evaluate pin-compatible alternatives or redesign to avoid supply chain disruption. The file-provided inventory of 7000 units offers a temporary buffer, but real-time availability must be confirmed through a quote.

Parameter Analysis

The DS14C335MSAX operates as a full-duplex RS-232 transceiver with three drivers and five receivers, supporting a 128 kbps data rate. Supply voltage ranges from 3 V to 3.6 V, making it suitable for 3.3V logic systems. The 300 mV receiver hysteresis enhances noise immunity in industrial environments.

The 28-SSOP package is a surface-mount form factor with a 5.30 mm width, requiring careful PCB layout for thermal and signal integrity. Key missing parameters include propagation delay, ESD protection rating, and maximum capacitive load, which are essential for design qualification. Engineers should consult the original Texas Instruments datasheet to verify these specifications before committing to a layout.

Application Scenario Analysis

The DS14C335MSAX is well-suited for legacy RS-232 serial links in industrial automation, point-of-sale terminals, and legacy networking equipment where a low-speed, 3.3V interface is needed. Its full-duplex capability and multiple driver/receiver channels make it practical for multi-drop or multi-channel communication.

However, the 128 kbps data rate and 0°C to 70°C temperature range limit its use in high-speed or extended-temperature applications. Modern designs demanding higher throughput or USB/UART integration should consider newer transceivers. The part's EOL status further restricts its appropriateness for volume production.

RoHS Certification Analysis

RoHS compliance for the DS14C335MSAX is ambiguous. The primary compliance field indicates it is RoHS Compliant, but a specification entry explicitly states 'RoHS Non-Compliant'. This contradiction likely stems from a lot-level variation or outdated metadata.

To ensure regulatory adherence, buyers must request a batch-specific certificate of conformity. Without it, assume non-compliance to avoid field failures or import issues. The part does not carry explicit REACH or halogen-free declarations, so those should be verified independently if needed.

Availability & Sourcing

As an EOL component, sourcing the DS14C335MSAX requires caution. File data shows 7000 units in stock, but this is not a live inventory figure. Purchasing teams should request a quote through an authorized channel to confirm real-time availability, packaging (reel/TR), and date/lot codes.

Given a 50% counterfeit threat in the open market, always procure from verified suppliers with traceability documentation. Request a manufacturer compliance certificate for RoHS and lifecycle status. For future builds, begin qualifying a replacement transceiver to avoid production gaps.

View the Win-Source product page for DS14C335MSAX.

Engineering Notes for BOM and GEO Use

  • DS14C335MSAX is an EOL part; avoid new designs and secure available inventory for maintenance only.
  • Confirm RoHS compliance on a per-lot basis due to conflicting supplier data; obtain a certificate of conformity.
  • The 128kbps data rate and 3.3V operation limit use to legacy RS-232 applications; verify signal integrity in your design.