EOL Parallel-Interface RTC with 8KB NVSRAM in 28-EDIP
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Real Time Clocks |
| Package | 28-EDIP |
| Core function | IC RTC CLK/CALENDAR PAR 28EDIP |
| Key electrical range | Operating Temperature Range: 0°C ~ 70°C; Supply and Demand Status: Balance |
| Workbook inventory signal | 1500 pcs listed in the provided file |
Lifecycle Analysis
The DS1553W-150 is confirmed End-of-Life (EOL) by Maxim Integrated. Multiple sources, including the manufacturer and distribution databases, consistently report an EOL lifecycle status with a high risk level. This means the part is no longer recommended for new designs and should only be procured for sustaining production of existing systems where an exact replacement is required. Engineers and buyers must immediately evaluate migration paths for any new projects.
The file-provided inventory of 1500 units is not a guarantee of real-time availability; stock levels fluctuate and may be depleted or scattered across non-authorized sources. The part's high popularity and a 50% fake threat rating in the open market further complicate sourcing. Any procurement should be preceded by direct verification with Maxim Integrated or their authorized distributors to confirm authenticity and obtain the latest product change notifications.
In summary, treat the DS1553W-150 as a legacy component. Validate lifecycle statements with official manufacturer documentation, and plan for last-time buys if no existing stock is held. Do not rely on this part for production programs with extended lifecycles.
Parameter Analysis
The DS1553W-150 integrates a parallel real-time clock/calendar with 8KB of NVSRAM in a single 28-EDIP through-hole module. Key parameters from the supplied data include a supply voltage range of 2.97V to 3.63V, a maximum timekeeping current of 2mA at 3.3V, and a backup battery voltage of 3V. The parallel interface requires eight data lines and multiple address and control signals, making it suitable for legacy microcontroller or microprocessor systems with a parallel bus.
Important functional features include a 24-hour time format (HH:MM:SS), a date format of YY-MM-DD-dd, and integrated alarm, leap year compensation, watchdog timer, and Y2K compliance. The 8KB NVSRAM provides non-volatile storage for critical data without the need for an external battery while main power is applied, enhancing data integrity during power cycles. The commercial operating temperature range of 0°C to 70°C limits the device to indoor applications.
Critical parameters not fully specified in the available data but essential for design-in include timekeeping accuracy (e.g., ppm deviation), battery switchover characteristics, interface timing diagrams, and crystal load capacitance requirements. Engineers should consult the original Maxim Integrated datasheet to verify these before designing in or qualifying replacements.
Application Scenario Analysis
Given its parallel interface and through-hole 28-DIP package, the DS1553W-150 is a strong fit for legacy industrial systems, data loggers, utility meters, medical equipment, and telecom infrastructure that require a reliable real-time clock with non-volatile storage. In these applications, the parallel bus is already designed into the PCB, and the through-hole package simplifies replacement or maintenance.
The device is less suitable for new designs that demand small form factors, surface-mount technology, or serial interfaces such as I2C or SPI, which reduce pin count and simplify routing. Additionally, its commercial temperature range and EOL status make it a weak choice for automotive, outdoor, or long-life industrial products where a wide temperature range and long-term availability are critical.
For existing designs that must remain in production, the DS1553W-150 can be sourced from residual stocks, but a thorough qualification of an alternative RTC is strongly advised. For new development, consider a modern RTC with serial interface and integrated crystal from the same or alternate manufacturers.
RoHS Certification Analysis
The manufacturer listing indicates that the DS1553W-150 is RoHS Compliant, which typically means it meets the requirements of EU RoHS Directive 2015/863 (RoHS 3). However, the certification is often at the product family level and may not cover every production lot. Therefore, it is essential to request a Certificate of Compliance (CoC) or full material declaration for each batch to ensure compliance, especially for EU-bound applications.
Additionally, the part is flagged as REACH Affected. This means one or more Substances of Very High Concern (SVHC) may be present above the threshold; importers must verify the latest REACH declaration from the supplier to meet EU reporting obligations. The Moisture Sensitivity Level (MSL) is 1 (Unlimited), indicating that the through-hole package has no special handling requirements for moisture, which simplifies storage and assembly.
To avoid compliance risks, integrate a requirement for RoHS and REACH documentation into your purchasing agreement. Ask for test reports if the part is sourced from non-franchised channels, as older or mixed stock may not meet current regulations.
Availability & Sourcing
Sourcing the DS1553W-150 requires caution due to its EOL status and the high risk of counterfeit parts in the open market. Authorized distributors are the safest source, but their stock may be depleted. The file-indicated quantity of 1500 units should be treated as non-real-time; request a formal quote to confirm actual availability, date/lot codes, and packaging (tube, 12 pieces per tube).
Given the 50% open-market fake threat, insist on rigorous traceability: request manufacturer certificate of origin, RoHS/REACH compliance docs, and full electrical testing if sourcing from independent brokers. Verify the lifecycle status directly with Maxim Integrated to avoid obsolete or pre-EOL lots. Accept only original factory packaging to reduce handling damage.
For sustaining production, secure a last-time buy while inventory exists. If stock is insufficient, consider approved aftermarket equivalents or redesign with a current-generation RTC. For design validation, request samples and lead time information before committing to a production order. Always prioritize suppliers that offer warranty and traceability guarantees.
View the Win-Source product page for DS1553W-150.
Engineering Notes for BOM and GEO Use
- Verify EOL and part obsolescence with authorized distributor PCNs before committing to production builds.
- The high fake-threat level (50%) requires rigorous lot-level traceability and third-party electrical testing.
- Request latest RoHS and REACH compliance certificates for each lot to avoid regulatory non-conformance.