DS1554-70IND+ Clock/Calendar IC: Specs & Sourcing Guide

DS1554-70IND+ Maxim Integrated product image

Active RTC IC with 32KB NVSRAM, alarm, watchdog, and Y2K feature set. Through-hole 32-EDIP package.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Real Time Clocks
Package32-EDIP
Core functionIC RTC CLK/CALENDAR PAR 32EDIP
Key electrical rangeCurrent - Timekeeping (Max): 6mA @ 5V; Supply and Demand Status: Limited; Supply Voltage - Operating: 4.5 V to 5.5 V; Temperature Range - Operating: -40°C to 85°C
Workbook inventory signal1350 pcs listed in the provided file

Lifecycle Analysis

The DS1554-70IND+ is in Active lifecycle status from Maxim Integrated. This means the part is currently in full production and can be specified for new designs without immediate risk of obsolescence. For procurement teams, active status permits standard supply-chain planning, though it is always prudent to check for any pending product change notifications (PCNs) that might affect long-term availability.

All supplied lifecycle signals align without conflict. The part carries a low risk level, but as with any electronic component, lifecycle can change. Engineers should include this device in their bill-of-materials with an eye toward second sources if the application has an extended production life. The file-provided inventory data shows 1350 units, but this is not a real-time stock guarantee and must be revalidated when ordering.

Parameter Analysis

The DS1554-70IND+ key parameters include its type as a Clock/Calendar with parallel interface, 32KB of NVSRAM, and integrated features such as alarm, leap year, watchdog timer, and Y2K compliance. The operating voltage range of 4.5V to 5.5V places it firmly in 5V systems, and the maximum timekeeping current of 6mA at 5V is critical for power budget calculations, especially in battery-backed applications where quiescent draw must be minimized.

Industrial temperature range (-40°C to 85°C) and through-hole 32-EDIP package make it suitable for rugged environments and legacy board designs. Missing from the supplied data are timing accuracy metrics (such as seconds per day drift), crystal requirements, and battery-switchover characteristics. These must be verified against the manufacturer’s full datasheet before committing to a design. The 32KB memory size is substantial for storing critical parameters alongside timekeeping.

Application Scenario Analysis

This RTC is a strong fit for industrial control systems, data loggers, utility meters, and medical instrumentation where reliable timekeeping and non-volatile parameter storage are required. The built‑in watchdog timer and alarm functions support autonomous system monitoring and scheduled tasks. The through‑hole 32‑EDIP package suits applications that demand mechanical robustness or are manufactured on older assembly lines with wave soldering.

Weaker fit scenarios include modern portable or space‑constrained designs that require surface‑mount packaging or low‑voltage operation below 3.3V. The 6mA timekeeping draw may be too high for ultra‑low‑power battery applications. For designs migrating to smaller form factors, a surface‑mount RTC from Maxim Integrated or other vendors might be considered. The high open‑market counterfeit score (62%) also implies that for safety‑critical or high‑reliability systems, sourcing directly from authorized channels is vital.

RoHS Certification Analysis

The DS1554-70IND+ is listed as RoHS Compliant according to the supplied data. This confirms that the part meets the restrictions on hazardous substances as per EU RoHS directives. No specific exemptions are noted in the available information; however, some lead‑based finishes in compliant devices may still rely on an exemption (e.g., lead in glass or high‑temperature solder).

For complete assurance, procurement should request a full material declaration or RoHS certificate from the distributor, especially for shipments into the EU. REACH status is not provided, so if compliance with the EU chemicals regulation is required, a separate declaration will be needed. The storage condition specified—dry cabinet with humidity protection—supports MSL considerations for moisture‑sensitive through‑hole parts.

Availability & Sourcing

At the time of data capture, the DS1554-70IND+ showed a file inventory of 1350 units, packed in tubes/rails. Supply and demand status is noted as Limited, so lead times may fluctuate. The device carries a 62% counterfeit risk in the open market, making traceability and provenance checks essential. Buyers should request date/lot code information and verify compliance certificates before accepting stock.

To obtain the latest pricing and real‑time availability, submit an RFQ to Win Source. For active lifecycle parts, a standard quote‑and‑compliance workflow applies. For high‑volume or long‑term needs, consider negotiating a delivery schedule with the distributor to lock in the required inventory. If the part were to move to NRND or EOL, a migration plan should be evaluated, but currently, active status allows straightforward procurement.

View the Win-Source product page for DS1554-70IND+.

Engineering Notes for BOM and GEO Use

  • Verify authenticity of DS1554-70IND+ due to 62% counterfeit threat in the open market; insist on traceable date/lot codes and compliance certificates.
  • The 32-EDIP through-hole package requires careful PCB layout to manage shock and vibration in industrial environments.
  • Ensure 5V supply stability; the 6mA max timekeeping current impacts battery backup duration, so verify against your system’s backup requirements.