DS1554W-120 Real-Time Clock Specs & Sourcing Guide

DS1554W-120 Maxim Integrated product image

Discontinued Maxim Integrated RTC with parallel interface, 32KB NVSRAM, and watchdog timer – verify stock and compliance

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Real Time Clocks
PackageTube
Core functionIC RTC CLK/CALENDAR PAR 32EDIP
Key electrical rangeCurrent - Timekeeping (Max): 4mA @ 3.3V; Temperature Range - Operating: 0°C ~ 70°C; Voltage - Supply: 2.97V ~ 3.63V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1554W-120 is discontinued, with lifecycle signals consistently indicating end-of-life status. Both the Excel lifecycle parameter and the product status confirm this part is no longer in production. This means the DS1554W-120 should not be used in new designs, and sustaining engineering teams must plan for a migration path or secure last-time-buy inventory.

Although the lifecycle signals agree on discontinuation, the slight wording discrepancy (EOL vs Discontinued) requires conservative procurement. The file-provided inventory shows only 1 unit, underscoring the scarcity. For any remaining stock, buyers must assume it is from the final production batches and verify authenticity and date codes. Without manufacturer revalidation, long-term availability cannot be assured. Treat the DS1554W-120 as a legacy part only suitable for repair of existing equipment where no alternative is feasible.

Parameter Analysis

Key parameters for the DS1554W-120 include its 2.97V to 3.63V supply voltage, 4mA maximum timekeeping current at 3.3V, and 32KB of NVSRAM. The parallel interface and through-hole 32-EDIP package define its integration requirements. Features like alarm, leap year compensation, watchdog timer, and Y2K compliance make it a full-featured RTC for embedded systems that need reliable timekeeping with non-volatile memory.

The 0°C to 70°C commercial temperature range limits use to indoor applications. Importantly, the programmable bit is listed as “Not Verified,” which may indicate that programmed chips require pre-loading or that datasheet clarification is needed. Missing datasheet details—such as battery backup voltage, crystal accuracy, and timing specifications—should be obtained from the original manufacturer’s documentation before qualifying this part for any design. Engineers should carefully review these missing parameters to ensure system compatibility.

Application Scenario Analysis

The DS1554W-120 was designed for legacy embedded systems requiring a parallel-interface RTC with large NVSRAM. Typical strong-fit applications include industrial controllers, medical instruments, and older computer motherboards where a 32KB memory depth and a through-hole DIP module were standard.

However, this part is a poor fit for modern designs due to its discontinuation, parallel interface (which consumes more pins than serial alternatives), and through-hole mounting (compared to surface-mount). New designs should consider active RTCs with I2C or SPI interfaces and smaller packages. For existing equipment, the DS1554W-120 may still be used as a drop-in replacement if exact form-factor and parallel protocol are required, but only after confirming software compatibility and verifying that the stock is genuine.

RoHS Certification Analysis

The DS1554W-120 presents conflicting RoHS data. One compliance field lists it as RoHS Compliant, but a specification explicitly states RoHS Non-Compliant. Additionally, REACH status is affected. This inconsistency likely arises from different production lots: earlier lots may have used leaded finishes, while later ones might have transitioned to lead-free before discontinuation.

Because the part is discontinued, no new RoHS certifications will be issued. Buyers must request lot-specific documentation and test reports for any stock offered. Without verified lot-level compliance, the DS1554W-120 cannot be assumed to meet EU RoHS directives. For equipment destined for the European market, this part may introduce compliance risk even if used in repair scenarios.

Availability & Sourcing

As a discontinued part, the DS1554W-120 is challenging to source. The file-provided inventory indicates only 1 unit, which is not a real-time guarantee. Given the 61% fake threat in the open market, procurement teams must exercise extreme caution. Request a quote from authorized distributors or trusted brokers who can provide traceable date codes and original packaging.

The standard package is 11 pcs per tube, but individual lot sizes may vary. For sustaining production, consider evaluating the DS1554W-120 as a last-time-buy item; secure inventory immediately after confirming lifecycle status and compliance. Because the part is no longer manufactured, alternatives like the DS1554 (base product number) may still be active in different variants, and an upgrade path should be explored with Analog Devices/Maxim Integrated. Always verify manufacturer notices and lifecycle status before committing to a purchase.

View the Win-Source product page for DS1554W-120.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance on a per-lot basis due to conflicting RoHS status signals.
  • The 61% fake threat rate demands strict anti-counterfeit inspection and traceability.
  • Do not rely on file-provided inventory; always request a live quote and confirm date codes.