EOL 2Kbit Dual-Port Asynchronous SRAM in 24-DIP Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | SRAM |
| Package | 24-PDIP |
| Core function | IC SRAM 2KBIT PARALLEL 24DIP |
| Key electrical range | Operating Supply Voltage: 4.5 V ~ 5.5 V; Operating Temperature Range: -40°C ~ 85°C (TA); Supply and Demand Status: Limited |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1609-50+ from Maxim Integrated is confirmed End-of-Life (EOL). This status indicates the manufacturer has discontinued production, and no further orders are accepted. For new designs, this part must not be used; engineers should select an alternate SRAM solution. For sustaining production, immediate action is required to secure remaining inventory and qualify a replacement.
The supplied inventory data shows extremely limited availability, with a file-provided quantity of just 1 unit. This snapshot is not a guarantee of real-time stock; actual availability must be verified through an RFQ. Additionally, a 50% counterfeit threat rating in the open market underscores the need for rigorous authenticity checks when sourcing this obsolete part. Procurement teams should obtain manufacturer date/lot codes and insist on traceable chain of custody.
Given the high risk, the recommendation is to expedite last-time buy orders if still possible and begin the design migration immediately. Relying on spot-market purchases for production is unsustainable.
Parameter Analysis
The DS1609-50+ is a 2Kbit dual-port asynchronous SRAM organized as 256 x 8 bits, with a fast 50ns access time. The dual-port architecture allows simultaneous read/write access from two independent buses, making it valuable in multi-processor or video buffer applications. The parallel memory interface simplifies integration with legacy microcontroller buses.
Key parameters for fit and qualification include the 5V-only operating voltage (4.5V–5.5V) and industrial temperature range (-40°C to +85°C). The 50ns write cycle time matches the access time, ensuring symmetric performance. The through-hole 24-DIP package (0.600” width) suits prototyping and legacy PCB designs but is not suitable for surface-mount assembly.
Engineers should verify additional specifications from the original Maxim Integrated datasheet, particularly standby and active current consumption, input/output capacitance, and timing diagrams for address setup/hold times. Without these, thermal and power budget analysis remains incomplete. The asynchronous interface lacks a clock, so system timing must be carefully analyzed, especially at voltage margins.
Application Scenario Analysis
The DS1609-50+ finds its most suitable application in legacy industrial control systems where a small, dual-port SRAM is used for data exchange between two processors or for temporary buffering. Common scenarios include PLC modules, motor control boards, and communication line cards designed in the late 1990s to early 2000s. Its 2Kbit density is insufficient for modern applications but adequate for storing configuration parameters or small message queues.
Weak-fit scenarios include any new design requiring higher memory density, lower power consumption, or surface-mount packaging. Modern alternatives offer larger capacities, serial interfaces, and lower voltages. Also, applications demanding guaranteed long-term availability should avoid this EOL part.
For repair and sustainment of existing equipment, this part may be essential, but sourcing must be approached with caution due to counterfeits. Engineers should consider functionally equivalent but still-active SRAMs from reputable manufacturers, though pin-compatibility is unlikely given the legacy DIP package.
RoHS Certification Analysis
The DS1609-50+ is listed as RoHS Compliant, indicating the part was manufactured to meet the EU Restriction of Hazardous Substances directive. However, the supplied data does not specify which revision (e.g., RoHS 3 or earlier) is met, nor are there details on exemptions for lead in glass of electronic components. As a through-hole DIP package, it likely complies with lead-free terminal finishing requirements.
Given the EOL status, any remaining stock may have been manufactured years ago, potentially under older compliance standards. Procurement should request a valid certificate of compliance or full material declaration from the distributor or broker. Without explicit REACH or halogen-free statements, no assumptions should be made about those regulations. The absence of MSL data is expected for through-hole parts, which are not moisture-sensitive in the same way as SMDs.
Availability & Sourcing
Sourcing the DS1609-50+ is challenging due to its EOL status and limited market supply. The file-provided inventory shows a single unit, but this figure is not real-time and cannot be relied upon for procurement decisions. Interested buyers should request a quote through an authorized channel or a reputable independent distributor to check current availability.
Key sourcing requirements include verifying date/lot codes to ensure parts are from a known-good lot and not counterfeit. The reported 50% counterfeit threat rate demands thorough authenticity testing, ideally including electrical verification. Original packaging should be intact tube packaging (24-PDIP), with storage conditions maintained in a dry and humidity-protected environment.
For production needs, immediately secure last-time buy inventory if still feasible from Maxim Integrated or its authorized distributors. Simultaneously, accelerate qualification of an alternative SRAM. When seeking quotes, explicitly request RoHS compliance documentation and ask about the traceability chain. Do not commit to production builds without confirming lifecycle status from the manufacturer’s official EOL notice.
View the Win-Source product page for DS1609-50+.
Engineering Notes for BOM and GEO Use
- DS1609-50+ is EOL; verify last-time buy dates with Maxim Integrated before committing to new designs.
- 50ns access time and dual-port architecture suit legacy industrial controllers; consider modern alternatives for new projects.
- RoHS compliant but confirm lot-level certification when procuring remaining stock to avoid compliance gaps.