Active Life Cycle, RoHS Compliant, 242B NVSRAM, Parallel Interface, 24-SOIC Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Real Time Clocks |
| Package | 24-SOIC |
| Core function | IC RTC CLK/CALENDAR PAR 24SOIC |
| Key electrical range | Current - Timekeeping (Max): 3mA @ 5V; Supply and Demand Status: Balance; Supply Voltage - Operating: 4.5 V to 5.5 V; Temperature Range - Operating: 0°C to 70°C |
| Workbook inventory signal | 2200 pcs listed in the provided file |
Lifecycle Analysis
Maxim Integrated currently lists the DS1685S-5+ as an Active part, with all lifecycle signals from the provided data aligning. This status indicates that the component is in full production, supported for both new designs and ongoing sustaining production. The risk level for procurement is low, meaning no immediate end-of-life or discontinuance notices are expected. However, engineers should always verify the lifecycle status through authorized distributors or manufacturer product change notifications to ensure continued alignment with production timelines.
The supplied data references an inventory quantity of 2200 units, but this number is file-provided and not a guarantee of real-time availability. For production planning, it is essential to confirm current stock levels and lead times directly with suppliers. As the part is Active, it is suitable for new design introductions without urgent migration concerns, yet regular monitoring of the manufacturer’s lifecycle communications is advised to catch any future changes.
Parameter Analysis
The DS1685S-5+ integrates key parameters that determine its fit in a design: a 24-SOIC surface-mount package, a main supply voltage of 4.5V to 5.5V, and a timekeeping current of 3mA maximum at 5V. The battery backup voltage range is specified from 2.5V to 3.7V, allowing use of common coin cells for data retention. The operating temperature range of 0°C to 70°C limits it to commercial-grade environments. The 242 bytes of NVSRAM and features like alarm, square wave output, and Y2K compliance make it suitable for applications requiring timestamped logging and event triggers. When designing in the DS1685S-5+, engineers should pay close attention to supply decoupling and layout to ensure stable operation of the parallel interface.
Missing from the provided specifications are critical timing parameters such as access time, bus interface timing diagrams, and clock accuracy over temperature. Additionally, details on packaging moisture sensitivity level (MSL) and reflow profiles are not listed. Before committing to the DS1685S-5+ in a BOM, designers should refer to the full Maxim Integrated datasheet to verify these electrical and mechanical specifications and ensure compatibility with the host processor and manufacturing processes.
Application Scenario Analysis
The DS1685S-5+ is well-suited for embedded systems that require battery-backed real-time clock functionality with non-volatile SRAM. Typical strong-fit applications include industrial controllers, point-of-sale terminals, data loggers, and medical devices operating within the 0°C to 70°C range. The integrated 242B NVSRAM and alarm features enable time-stamped event recording and scheduled wake-up functions without external memory components. Its parallel interface simplifies integration with legacy microcontrollers or processors that have parallel address/data buses.
This IC is a weak fit for designs requiring extended temperature ranges beyond 70°C, as it is rated only for commercial grade. Similarly, low-power applications operating at 3.3V or lower may not be compatible, since the main supply voltage must be at least 4.5V. Applications demanding high-precision timekeeping (e.g., sub-minute drift per day) should evaluate the on-chip crystal oscillator accuracy, which is not specified in the provided data. In such cases, external clock calibration or a different RTC may be necessary.
RoHS Certification Analysis
The DS1685S-5+ carries a RoHS Compliant designation according to the provided data. While the exact directive is not stated, the part is assumed to meet the requirements of the European Union's Restriction of Hazardous Substances directive, commonly known as EU RoHS. Because no specific version like EU 2015/863 is confirmed, procurement teams should request the full material composition declaration or certificate of compliance from Maxim Integrated to verify that the part meets the latest restricted substance limits.
It is important to note that RoHS compliance at the part number level may not automatically ensure lot-level consistency. For high-reliability applications, spot-checking or requiring lot-specific compliance documentation is recommended. No REACH or halogen-free declarations are present in the source data, so if these are required for your market, additional verification with the manufacturer is necessary.
Availability & Sourcing
The DS1685S-5+ is categorized as an Active component with balanced supply and demand, and a high popularity rating. The provided workbook quantity is 2200 units, but this is a file snapshot and may not reflect real-time inventory; always request a current quote. Sourcing should go through authorized Maxim Integrated distributors or reputable brokers, with part traceability documentation including date and lot codes to mitigate the 31 percent fake threat in the open market. Packaging is supplied in tube/rail, and storage conditions require dry cabinets with humidity protection.
To purchase the DS1685S-5+, contact Win Source or other approved suppliers for a quote that includes compliance certificates (RoHS, possible REACH), along with confirmation of the Active life cycle and current lead time. For high-volume production, negotiating a buffer stock or scheduling deliveries may be beneficial given the part's common use. Engineers should validate lifecycle status and compliance documentation with every shipment to ensure consistent quality and regulatory adherence.
View the Win-Source product page for DS1685S-5+.
Engineering Notes for BOM and GEO Use
- Confirm the exact RoHS directive (e.g., EU 2015/863) with the manufacturer for full compliance documentation.
- Ensure the 4.5V–5.5V operating voltage and 0°C–70°C temperature range fit your design margins.
- Validate NVSRAM size and alarm/square-wave output functionality against system requirements before BOM finalization.