DS1731U+ Maxim Integrated Digital Temp Sensor Specs & Sourcing Guide

DS1731U+ Maxim Integrated product image

Active part with I2C output, 11-bit resolution, and ±1°C accuracy. RoHS compliant, 8-uMAX package.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryTemperature Sensors - Analog and Digital Output
PackageTube
Core functionSENSOR DIGITAL -55C-125C 8UMAX
Key electrical rangeOutput Type: I2C; Sensing Temperature - Local: -55°C ~ 125°C; Temperature Range - Operating: -55°C ~ 125°C; Voltage - Supply: 2.7V ~ 5.5V
Workbook inventory signal1449 pcs listed in the provided file

Lifecycle Analysis

The DS1731U+ from Maxim Integrated is classified as Active with a low risk level, based on multiple consistent indicators: the Excel lifecycle parameter shows Active, the official Lifecycle Status is Active, and the Product Status is listed as Active. There are no conflicts among these signals, which means Maxim Integrated continues to manufacture and support this temperature sensor for both new designs and sustaining production.

When a part is Active, procurement teams can plan for standard lead times and should not expect immediate obsolescence. However, for products with long qualification cycles, it is prudent to periodically revalidate lifecycle status directly with the manufacturer. The file-provided inventory quantity of 1449 units suggests current stock availability, but this is not a guarantee of real-time supply; quantities can change rapidly. For new designs, the Active status supports confident integration, provided that a second-source or migration strategy is evaluated for the long term.

Parameter Analysis

The DS1731U+ offers local digital temperature sensing with an I2C interface, making it straightforward to integrate into microcontroller-based systems. The sensor’s operating temperature range matches its sensing range of -55°C to 125°C, which is essential for applications that must operate in harsh environments. Accuracy is specified as ±1°C in the 0°C to 70°C range, and ±2°C over the full temperature span, which is typical for budget-conscious designs that don’t require high-precision thermal metrology.

Resolution is 11 bits, providing 0.125°C per LSB, fine enough for most thermal management and overtemperature protection loops. The supply voltage range of 2.7V to 5.5V allows direct connection to 3.3V or 5V systems without level shifting. Notable features include programmable overtemperature limits, one-shot conversion mode, and standby operation, which help reduce power consumption in battery-powered designs. Missing from the supplied data are parameters such as supply current, conversion time, and I2C address options. Engineers should consult the full datasheet to verify these values for power budget calculations and bus loading.

Application Scenario Analysis

The DS1731U+ is well-suited for applications requiring basic digital temperature monitoring with a simple I2C interface. Strong-fit scenarios include PC motherboard and peripheral thermal management, industrial automation panels, HVAC equipment, and battery charging circuits where a local sensor can track ambient or board temperature. Its programmable limit and output switch allow it to function as a standalone thermostat, reducing host processor intervention.

Weak-fit scenarios involve remote temperature sensing, where a diode-connected transistor is needed, or high-precision medical devices that demand accuracy tighter than ±1°C across a wide range. The part’s plastic uMAX package and surface-mount design are not ideal for applications with extreme mechanical stress or high vibration unless additional conformal coating is applied. For applications that require an analog voltage output, an alternative sensor type would be necessary.

RoHS Certification Analysis

The DS1731U+ is listed as RoHS Compliant in the provided data, which means it conforms to the European Union’s Restriction of Hazardous Substances directive. This is a key requirement for products sold in the EU and many other markets. The part is also REACH Unaffected, indicating that it does not contain substances of very high concern above the threshold, though REACH alone is not a substitute for RoHS certification.

Additionally, the Moisture Sensitivity Level (MSL) is Level 1 (Unlimited), which is the most robust classification and indicates that the device is not sensitive to moisture-induced damage during reflow soldering. This eases handling and storage requirements. Even with these certifications, procurement professionals should request a manufacturer’s declaration or certificate of compliance for specific lot numbers when full traceability is required, as compliance status can vary at the lot level.

Availability & Sourcing

Maxim Integrated’s DS1731U+ is an Active part, and the file-provided quantity of 1449 units suggests current stock availability through the reporting channel. The standard packaging is tube, with 50 pieces per tube, which suits prototype and small-to-medium production runs. For higher volumes, alternative packaging options may be available from the manufacturer.

A significant sourcing risk is the reported fake threat percentage of 65% in the open market. This underscores the importance of purchasing only from authorized Maxim Integrated distributors or directly from the manufacturer to avoid counterfeit devices. When sourcing, request a quote that includes factory date codes, lot traceability, and RoHS compliance documentation. For new designs, ensure that the part’s lifecycle status is verified as Active at the time of order. Typical workflows involve issuing an RFQ, comparing authorized channels, and securing inventory with confirmed authenticity.

View the Win-Source product page for DS1731U+.

Engineering Notes for BOM and GEO Use

  • Verify supply voltage (2.7V–5.5V) and I2C bus voltage levels; ensure compatible logic levels for your MCU.
  • With a reported 65% fake threat in the open market, source only from Maxim authorized distributors to guarantee authentic silicon.
  • Account for accuracy degradation to ±2°C over full -55°C to 125°C range when designing thermal alarm thresholds.