DS1744-70IND+ Real-Time Clock: Specs & Sourcing Guide

DS1744-70IND+ Maxim Integrated product image

Active RTC with parallel interface, 32KB NVSRAM, and -40°C to +85°C operation in a 28-EDIP package.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Real Time Clocks
Package28-EDIP
Core functionIC RTC CLK/CALENDAR PAR 28EDIP
Key electrical rangeCurrent - Timekeeping (Maximum): 4mA @ 5V; Operating Supply Voltage: 4.5 V ~ 5.5 V; Operating Temperature Range: -40°C ~ 85°C; Supply and Demand Status: Limited
Workbook inventory signal111 pcs listed in the provided file

Lifecycle Analysis

The DS1744-70IND+ from Maxim Integrated is actively listed as an active part, with all available lifecycle signals aligning on a production-ready status. The supplied data indicates an Active lifecycle and a low risk level, meaning that engineers can use this part in new designs without immediate concerns about discontinuation. However, an Estimated EOL Date value of 2024 is also present in the source specifications. This conflicts with the Active status and should be verified directly with Maxim Integrated or an authorized distributor before committing to high-volume orders. For sustaining production, the active status supports continued procurement, but the file-provided inventory quantity of 111 units does not reflect real-time global stock, so buyers should request current availability when planning. Overall, treat the DS1744-70IND+ as an active component with a moderate verification step needed on its long-term product roadmap.

Parameter Analysis

The DS1744-70IND+ is a parallel-interface real-time clock and calendar with 32KB of integrated non-volatile SRAM. Key specifications include an operating voltage range of 4.5V to 5.5V and an industrial temperature span of -40°C to +85°C, making it suitable for rugged embedded systems. The timekeeping current is specified at a maximum of 4mA when operating at 5V, which is relevant for power budgeting in 5V-tolerant designs. Factory-programmed features include leap-year compensation, Y2K compliance, and a YY-MM-DD-dd date format combined with HH:MM:SS 24-hour time.

For design integration, the parallel interface allows fast register access, while the integrated 32KB NVSRAM provides ample storage for time-stamped data logs or system configuration. However, several datasheet details are not present in the provided data and must be verified: the backup-battery switchover scheme and voltage threshold, clock accuracy over temperature, and the internal register map. Designers should obtain the full datasheet to confirm these parameters before finalizing a schematic or layout. The through-hole 28-EDIP package also influences board density and mechanical clearances in new designs.

Application Scenario Analysis

The DS1744-70IND+ fits well in industrial control systems, data loggers, and legacy equipment upgrades where a 5V supply rail is standard and through-hole mounting is acceptable. Its parallel interface and direct bus connection suit microcontroller-based designs that require fast time-stamp reads without serial protocol overhead. The integrated 32KB NVSRAM is useful for storing critical system parameters that must survive power loss, such as calibration constants or event logs.

This component is less ideal for battery-operated or low-power embedded applications, where the 4mA timekeeping current may be excessive compared to modern RTCs with sub-μA backup currents. Surface-mount designs or space-constrained PCBs will also find the 28-DIP module challenging to accommodate. Additionally, the 48% fake threat rating reported in open-market data highlights the importance of sourcing from authorized channels to avoid counterfeit parts that could compromise reliability in field-deployed systems.

RoHS Certification Analysis

The DS1744-70IND+ carries a RoHS Compliant status as per the supplied specification data. This designation indicates that the component meets EU RoHS directives for the restriction of hazardous substances, including lead, mercury, and cadmium. While the specific directive version is not stated, RoHS compliance generally aligns with RoHS 3 (EU 2015/863) for currently active electrical components.

No additional compliance information, such as REACH, halogen-free, or MSL ratings, is provided in the source data. For applications requiring full material declaration, engineers should request the analog materials certificate from the manufacturer. Lot-level RoHS compliance should also be confirmed at receipt inspection, especially when sourcing from independent distributors, to ensure that each shipment meets regulatory requirements. Because the part is through-hole and may have been manufactured over many years, a one-time re-verification of the compliance status for older date codes is advised.

Availability & Sourcing

File-provided data indicates a stock quantity of 111 units in tube packaging, with a supply-and-demand status of Limited. The component also carries a significant open-market fake-threat rating of 48%. Because availability is not real-time and inventory levels can change quickly, engineers and buyers should request a quote to confirm current stock, lead times, and pricing. When sourcing the DS1744-70IND+, emphasize procurement from Maxim Integrated authorized distributors to mitigate counterfeit risks and ensure full manufacturer warranty.

The component’s active lifecycle supports standard RFQ workflows, but the limited supply signal suggests that securing buffer inventory may be prudent for production runs. Always require documentation verifying lot codes, date codes, and RoHS compliance certificates with each shipment. For long-term program planning, contact Maxim Integrated to validate the potentially outdated EOL estimate and obtain a formal product life-cycle statement.

View the Win-Source product page for DS1744-70IND+.

Engineering Notes for BOM and GEO Use

  • Verify the EOL date discrepancy with Maxim Integrated before committing to new designs.
  • Source only through authorized distributors to counter the 48% open‑market fake threat.
  • Ensure 5 V supply stability and confirm backup‑battery switching requirements from the full datasheet.