Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryData Acquisition - Digital Potentiometers
PackageTube
Core functionIC DGTL POT 10KOHM 64TAP 8UMAX
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Resistance (Ohms): 10k; Resistance - Wiper (Ohms) (Typ): 400 (Max); Temperature Coefficient (Typ): 750ppm/°C
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1809U-010 from Maxim Integrated carries a Discontinued lifecycle status, with risk level high. This means the part is no longer recommended for new designs and is in the final phase of availability. Conflicting signals in the source data—EOL in one field and Discontinued in another—reinforce the need for conservative procurement planning. Engineers should treat this as an end-of-life component.

For legacy systems that depend on this digital potentiometer, immediate action is required to secure remaining inventory. File-provided data suggests only one unit remains, but this is not a real-time guarantee. Contact authorized distributors to confirm last-time buy windows and final shipment dates before committing to production schedules.

Using the DS1809U-010 in new designs poses significant supply risk and potential redesign costs. Validate any stock found against manufacturer date codes and consider alternate solutions from Maxim Integrated or other suppliers that offer compatible form, fit, and function.

Parameter Analysis

Key parameters of the DS1809U-010 include a 10kΩ end-to-end resistance with 64 taps, providing a linear taper. The pushbutton interface distinguishes it from serial-communicated pots, making it suitable for manual up/down adjustment without a microcontroller. Non-volatile memory retains the wiper position during power cycles, a critical feature for settings that must persist. The device operates from a 5V supply and tolerates an industrial temperature range of –40°C to +85°C.

Engineering margins should account for the ±20% resistance tolerance and a typical temperature coefficient of 750ppm/°C. A maximum wiper resistance of 400Ω can affect low-side accuracy, so evaluate impact on your signal chain. The 8‑pin uMAX/uSOP surface‑mount package aids compact layouts but requires careful PCB footprint design.

Missing datasheet details that warrant verification include the minimum and maximum supply voltage range (specified only as 5V), the wiper current rating, and any debounce timing for the pushbutton inputs. For system integration, also confirm the internal charge pump behavior if used near supply limits.

Application Scenario Analysis

The DS1809U-010 fits manual‑adjustment roles such as audio volume control, LCD brightness trimming, analog set‑point dialing, or simple calibration circuits. Its pushbutton interface and non‑volatile memory make it convenient for products where user interaction without a host processor is desired. The 10kΩ impedance and 64‑step resolution suit low‑ to medium‑precision settings, and the industrial temperature grade supports use in moderately harsh environments.

However, its discontinuation severely limits new‑design viability. Even in sustaining production, the part’s ±20% tolerance and 750ppm/°C tempco may not meet tighter accuracy requirements. The 5V‑only supply specification (without a stated range) can be a constraint in low‑voltage or battery‑powered designs.

For high‑reliability or safety‑critical applications, the DS1809U-010 is not recommended due to its end‑of‑life status and uncertain supply. Engineers should evaluate modern replacements that offer I²C/SPI interfaces, improved tolerance, and active lifecycle support, though a pin‑compatible drop‑in may not exist without layout changes.

RoHS Certification Analysis

RoHS compliance data for the DS1809U-010 is contradictory. The high‑level compliance field indicates RoHS Compliant, while the detailed specification list marks the part as RoHS Non‑Compliant. This inconsistency could arise from different production batches, where some lots were manufactured before RoHS directives took full effect, or from errors in legacy database entries.

When a conflict exists, procurement teams must assume a conservative stance: treat the component as potentially non‑compliant until the specific lot is verified. Request a certificate of compliance from the supplier for the exact stock being purchased. Without this documentation, using the DS1809U-010 in products destined for EU markets risks non‑compliance with RoHS regulations.

Even if a particular lot is compliant, note that the device is discontinued, so the availability of RoHS‑certified units will only diminish. Include this verification step in your incoming inspection process to avoid regulatory penalties and costly rework.

Availability & Sourcing

As a discontinued part, the DS1809U-010 is now in the diminishing‑supply phase. File‑provided data indicates a single remaining unit, but this is not a live inventory count. To source this component, use an RFQ process targeting authorized distributors and reputable independent brokers. Clearly specify manufacturer part number, required date/lot codes, and desired packaging (tube).

Given the lifecycle status, insist on traceability documentation and a vendor‑provided certificate of conformance. Verify that the stock is not refurbished or counterfeit by checking physical marking, date code consistency, and where possible, electrical testing. Moisture sensitivity level (MSL) is not specified in the available data; assume standard MSL‑1 precautions unless otherwise confirmed.

For legacy production, act quickly to secure enough units to cover projected lifetime demand. If insufficient stock is available, begin evaluating migration options. Maxim Integrated may not offer a direct replacement, so consider functional equivalents from other manufacturers that meet your pinout and performance requirements.

View the Win-Source product page for DS1809U-010.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance on a per-lot basis; conflicting data may indicate non-compliant stock.
  • Due to discontinuation, secure inventory for legacy designs and initiate qualification of a pin-compatible replacement.
  • Confirm power-supply behavior at 5V nominal and assess wiper current capacity before reuse.