DS1813-15+ PMIC Supervisor Specs & Sourcing Guide

DS1813-15+ Maxim Integrated product image

Simple Reset IC with 4.13V Threshold, TO-92-3 Package

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryPMIC - Supervisors
PackageTO-226-3, TO-92-3 (TO-226AA)
Core functionIC 4.
Key electrical rangeNumber of Voltages Monitored: 1; Output: Open Drain or Open Collector; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C (TA)
Workbook inventory signal2088 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of the DS1813-15+ is reported as Unknown. Without manufacturer confirmation, using this part in new designs carries medium risk. Engineers should contact Maxim Integrated (now part of Analog Devices) to obtain the official product lifecycle status before committing to production.

The supplied data does not include lifecycle signals such as Not Recommended for New Designs (NRND) or End-of-Life (EOL) notices. The inventory file shows 2088 units, but this figure is not real-time and may not represent current market availability. For new designs, it is prudent to verify the long-term production plan directly with the manufacturer or authorized distributors.

For sustaining production, secure additional stock if the lifecycle is found to be stable. If the part proves to be discontinued, a redesign may be necessary. Therefore, early verification is essential.

Parameter Analysis

Key parameters for the DS1813-15+ include its voltage threshold of 4.13V, an active-low open-drain output, and a minimum reset timeout of 100ms. These specifications define its behavior in monitoring a 5V rail: the output asserts low when the supply drops below the threshold and remains asserted for at least 100ms after the voltage recovers. The open-drain output requires a pull-up resistor to the system logic supply, allowing interface flexibility with different voltage levels.

The through-hole TO-92-3 package supports manual assembly and prototyping but limits use in high-density SMD designs. Operating temperature range is -40°C to 85°C, suitable for many industrial applications. However, critical information missing from the supplied data includes threshold accuracy, supply current, and reset timeout tolerance. Always consult the official DS1813-15+ datasheet for precise timing and electrical characteristics.

Application Scenario Analysis

The DS1813-15+ is well-suited for monitoring 5V power supplies in embedded systems, industrial controllers, and consumer electronics where a simple reset signal is needed during power-up and brownout events. Its 4.13V threshold is compatible with 5V ±5% rails, providing reliable undervoltage detection.

Through-hole packaging makes it ideal for prototyping, low-volume production, or legacy equipment where SMD rework is not feasible. It is a poor fit for portable or low-voltage devices requiring monitoring of 3.3V or lower rails, as the threshold is fixed and cannot be adjusted. Also, it lacks advanced features like watchdog timers or manual reset inputs, so it should only be used in applications with basic reset requirements.

RoHS Certification Analysis

The DS1813-15+ is listed as RoHS Compliant, which generally means it meets EU hazardous substance restrictions. The specific RoHS revision is not documented in the supplied data; typical compliance for such parts targets RoHS (EU 2015/863). As a through-hole component, lead-frame and plating finishes must be lead-free, but verification per production lot is advisable, especially for EU market entry.

No REACH, halogen-free, or MSL statements are provided. Since Maxim Integrated is now part of Analog Devices, access the latest official compliance certificates from the manufacturer's support portal. For high-reliability or regulated applications, request a full material declaration to confirm exemption applicability.

Availability & Sourcing

Given the unknown lifecycle status, sourcing the DS1813-15+ requires extra diligence. The file indicates 2088 pieces in stock and notes a shortage condition, but this data is not real-time. To obtain current availability, pricing, and lead times, submit a request for quotation (RFQ) through authorized channels.

When sourcing, request date/lot codes to ensure traceability and verify that RoHS compliance documentation corresponds to the shipped lot. The part is supplied in bulk packaging, which may require additional handling. Because the lifecycle is unconfirmed, do not commit to long-term production without firm manufacturer confirmation; consider evaluating alternative supervisors with defined lifecycles if risk is unacceptable.

For immediate needs, secure inventory and monitor lead times closely. For new designs, parallel qualification of a second-source supervisor is recommended to mitigate supply chain risk.

View the Win-Source product page for DS1813-15+.

Engineering Notes for BOM and GEO Use

  • Confirm reset threshold accuracy and hysteresis from the official DS1813 datasheet before finalizing voltage rails; typical 4.13V threshold may vary with temperature and supply.
  • Ensure an external pull-up resistor is connected to the open-drain output to match system logic levels; the reset signal remains low until the reset timeout period expires.
  • Given the indicated shortage status, buffer safety stock and consult manufacturer for product lifecycle to avoid production disruptions.