EOL Maxim Integrated Simple Reset/Power-On Reset Supervisor, 4.62V Threshold, TO-92-3, Sourcing and Replacement Guidance
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | PMIC - Supervisors |
| Package | TO-226-3, TO-92-3 (TO-226AA) |
| Core function | IC SUPERVISOR 1 CHANNEL TO92-3 |
| Key electrical range | Number of Voltages Monitored: 1; Output: Open Drain or Open Collector; Supply and Demand Status: Balance; Temperature Range - Operating: -40°C ~ 85°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Maxim Integrated DS1813-5 is a simple reset/power-on reset supervisor, now marked as End-of-Life (EOL). All lifecycle signals align on EOL status, with no conflicting information. This part is not recommended for new designs; it should be considered only for sustaining production where a form-fit-function replacement has not been qualified.
Given the EOL status, procurement risk is high. The workbook indicates a single unit available, but this is a file-provided snapshot and does not guarantee real-time availability. Buyers should confirm stock with the supplier and check whether the manufacturer has already closed last-time buy (LTB) windows. If inventory must be secured, it should be purchased immediately with thorough incoming inspection to mitigate counterfeit risks.
Engineers should plan a migration to an active alternative. Maxim Integrated (now Analog Devices) may offer newer supervisors with similar specifications, but a direct drop-in replacement is not assured. Reviewing the datasheet for exact timing and threshold tolerances is essential when evaluating alternatives.
Parameter Analysis
The DS1813-5 is a through-hole, TO-92-3 packaged supervisor that monitors a single supply voltage. Key parameters provided include a fixed threshold of 4.62 V, open drain active-low reset output, and a minimum reset timeout of 100 ms. The operating temperature range is –40°C to +85°C, making it suitable for standard commercial and industrial ambient conditions.
The 4.62 V threshold targets 5 V rails with a tolerance window that requires careful analysis using the full datasheet. The open drain output allows wired-OR connections with other reset sources or simple interface with different logic levels through an external pull-up resistor. The minimum 100 ms reset timeout ensures that the monitored circuit properly resets after the supply voltage returns above the threshold, but the actual timeout variation should be verified against the application’s reset requirements.
Several important specifications are absent from the provided data and must be checked in the official datasheet: supply current consumption, reset threshold accuracy (typically offered as a percentage), and any watchdog or manual reset features. Additionally, the MSL Level 1 rating is unlimited, which is typical for through-hole parts and simplifies storage. The 77% fake threat metric underscores the need to source from authorized channels and verify parametric authenticity through testing.
Application Scenario Analysis
This reset supervisor is a strong fit for legacy 5 V microcontroller or digital logic systems that require a simple, external power-on reset function. The through-hole TO-92-3 package suits prototyping, repair, or manufacturing lines that still use hand-soldered or wave-soldered boards. Applications in older industrial controls, consumer electronics, or automotive aftermarket equipment where space is not a premium can still use this part effectively.
It is a weak fit for modern, high-density designs that use surface-mount technology and multi-rail voltage supervision. The single monitored voltage and simple reset without additional features such as watchdog or voltage monitoring on multiple rails limit its use in complex system-on-chip environments. Additionally, the open drain output requires an external pull-up resistor, which may add component count and board space.
For designs that need a direct plug-in replacement, the exact footprint and pinout of the TO-92-3 package must be matched. Engineers should verify that the threshold voltage tolerance and reset delay timing of any substitute part align with system requirements, particularly in noise-sensitive analog or mixed-signal circuits.
RoHS Certification Analysis
The compliance data for the DS1813-5 presents a contradiction: the supplier listing header states ‘RoHS Compliant’, but the detailed specification field explicitly says ‘RoHS Non-Compliant’. Such discrepancies are not uncommon with EOL parts sourced from aggregator databases and underline the necessity of direct verification. Without clarification, it is unsafe to assume RoHS 3 (EU 2015/863) compliance for new equipment destined for the European market.
The provided MSL Level 1 indicates unlimited floor life, suggesting that moisture sensitivity is not a concern. There is no REACH or halogen-free data included. If the part is indeed non-compliant, it may still be used in legacy systems that were originally exempted, but procurement for any new EU-bound product would require a compliant alternative.
The safest course is to request a full material declaration or certificate of compliance directly from Maxim Integrated/Analog Devices. Buyers should also check the manufacturer’s end-of-life notice for any official statement on substance compliance. Do not rely on secondary database entries without manufacturer documentation.
Availability & Sourcing
The DS1813-5 is an EOL product with a high counterfeit risk (77% fake threat). The file-provided stock quantity shows a single unit, but this is not a live inventory figure. Buyers must request a quote to determine current availability across distributors. Given the obsolete status, available stock is likely limited and may come from non-authorized brokers, increasing the risk of receiving counterfeit or re-marked components.
To mitigate risk, insist on full traceability documentation, including date and lot codes, original manufacturer packaging, and a certificate of conformance. The part is supplied in bulk (TO-92-3) with through-hole mounting, which may require careful handling during shipping to avoid bent leads. Verification of authenticity through electrical testing, such as measuring the threshold voltage and reset delay against the datasheet, is strongly advised.
Sourcing strategy depends on your production status. For immediate short-term needs, secure available inventory while verifying lifecycle with the manufacturer. For longer-term planning, evaluate migration to an active supervisor; request samples and qualification data early. Always confirm RoHS compliance status as part of the sourcing decision, and consider requiring a supplier declaration of conformity for each shipment.
View the Win-Source product page for DS1813-5.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance status as the datasheet extract and supplier listing conflict; request a manufacturer certificate before use in regulated markets.
- Due to end-of-life status, secure remaining inventory now and create a migration plan to an active, pin-compatible supervisor for future production.
- With a 77% fake threat rating, source only from authorized distributors and insist on full traceability documentation for each lot.