DS1821 Digital Temperature Sensor Specs & Sourcing Guide

DS1821 Maxim Integrated product image

EOL 1-Wire digital temperature sensor, -55°C to 125°C, TO-92-3 package. Limited availability, high counterfeit risk.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryTemperature Sensors - Analog and Digital Output
PackageNot available in supplied data
Core functionSENSOR DIGITAL -55C-125C TO92-3
Key electrical rangeSupply and Demand Status: Limited
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1821 is officially designated End-of-Life (EOL) by Maxim Integrated, with all available lifecycle signals confirming this status. For engineers, this means the part is no longer recommended for new designs and should only be procured for maintaining existing production or repair needs. The risk level is high: without active manufacturing, future supply depends entirely on limited distributor stock or aftermarket sources. Any commitment beyond immediate requirements carries supply continuity risk. Designers should immediately begin evaluating functional replacements that are in active production. The file-provided inventory shows 1 unit, which is not a real-time guarantee and likely reflects minimal remaining stock. Before relying on any available quantity, validate with a formal RFQ and confirm the manufacturing date code, as older batches may have degraded moisture sensitivity if not stored properly. Procure only for bridge buys while transitioning to a modern sensor.

Parameter Analysis

The DS1821 is a digital temperature sensor with a 1-Wire interface, offering a simple single-data-line connection that reduces pin count and simplifies PCB routing. It operates over a supply voltage range of 2.7V to 5.5V, making it compatible with both 3.3V and 5V logic systems. The sensor’s 8-bit resolution provides temperature data in 1°C increments, which is adequate for many threshold-based monitoring applications. The specified accuracy is ±1°C within the 0°C to 85°C range, but accuracy outside this range is not characterized, so designers should derate expectations for extreme temperatures. The through-hole TO-92 package is suitable for legacy through-hole designs but complicates modern SMT assembly. Key missing datasheet parameters to verify before integration include supply current, conversion time, and timing requirements for 1-Wire communication, as these influence power budgeting and firmware design. Also confirm the thermostat output switch characteristics if using the programmable limit function.

Application Scenario Analysis

Given its 1-Wire digital output and on-chip thermostat functionality, the DS1821 is a strong fit for legacy industrial and consumer applications that need simple temperature threshold detection with a digital readout. Examples include PC motherboard thermal monitoring, HVAC thermostat interfaces, appliance temperature control, and basic cold-chain data loggers. Its through-hole package aligns with older product designs that cannot easily transition to SMD sensors. However, the DS1821 is a weak fit for new designs requiring high resolution (less than 1°C), fast conversion rates, or I2C/SPI connectivity. Applications demanding guaranteed accuracy across the full -55°C to 125°C range also exceed the sensor’s specified ±1°C accuracy window. As an EOL part, the DS1821 is best suited for maintenance and repair of existing equipment; new projects should adopt modern alternatives with better resolution, smaller packaging, and longer lifecycle guarantees.

RoHS Certification Analysis

The DS1821 is indicated as RoHS Compliant, meaning it meets the original EU Restriction of Hazardous Substances directive requirements. However, the exact directive version (e.g., RoHS 2 or the more stringent RoHS 3 under EU 2015/863) is not confirmed. For EOL components, compliance may have been assessed under an older standard, and material declarations might not include restrictions added later, such as certain phthalates. Therefore, for products shipping into the EU, it is essential to request a lot-specific RoHS certificate from the supplier alongside a full material declaration. REACH compliance is not mentioned in the available data and should be verified separately if SVHC-free status is required. Halogen-free and MSL ratings are also not provided; confirm these with the distributor if critical for assembly process compatibility.

Availability & Sourcing

The DS1821 is EOL, and current availability is extremely limited. The file-indicated stock quantity of 1 unit is not a real-time guarantee and likely understates market scarcity. Procurement teams should treat any found inventory as residual and request a formal quotation to confirm exact quantity, date codes, and packaging (the standard configuration is tray for TO-92). Given the part’s high popularity and EOL status, open-market counterfeit risk is elevated at 33%, so insist on full lot traceability, authorized distribution chain documentation, and industry-standard testing (e.g., x-ray or decapsulation) for any third-party sources. Request a sample for verification before committing to purchase. For new designs, avoid sourcing the DS1821 entirely—evaluate and qualify an active replacement. For legacy support, secure remaining authenticated stock through reputable brokers and plan a last-time buy against forecasted maintenance demand. Contact Win Source or your preferred distributor to request a current quote and confirm availability.

View the Win-Source product page for DS1821.

Engineering Notes for BOM and GEO Use

  • The DS1821 is EOL: secure existing inventory and migrate to newer alternatives for new designs.
  • Verify RoHS compliance per lot; assess REACH compliance if required for EU shipments.
  • Counterfeit risk is high (33% reported open market); insist on lot traceability and testing.