Active digital temperature sensor with 1-Wire interface, ±2°C accuracy, and -55°C to 125°C range in TO-92-3 package.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Temperature Sensors - Analog and Digital Output |
| Package | TO-92-3 |
| Core function | SENSOR DIGITAL -55C-125C TO92-3 |
| Key electrical range | Output Type: 1-Wire; Sensing Temperature - Local: -55°C to 125°C; Supply and Demand Status: Limited; Supply Voltage - Operating: 3 V to 5.5 V |
| Workbook inventory signal | 2000 pcs listed in the provided file |
Lifecycle Analysis
The DS1822+ from Maxim Integrated is classified as Active, indicating that the manufacturer is continuing full production and support. This lifecycle status makes the part suitable for both new designs and volume production without near-term obsolescence concerns. All available lifecycle signals—including the Excel-supplied status and manufacturer listings—align without conflict, reinforcing that the DS1822+ remains a standard, actively manufactured component.
However, the open market for this sensor carries a reported fake threat level of 66 percent, which is notably high. Engineers and procurement teams should treat this as a strong warning to source the DS1822+ exclusively through authorized Maxim Integrated channels. Even though the part is Active, verifying current lead times and delivery schedules directly with the manufacturer is advisable, as supply-and-demand status is noted as Limited. The inventory quantity shown in the provided file (2000 units) is not a guarantee of real-time availability and must be confirmed during the quoting process.
Parameter Analysis
The DS1822+ offers an 11-bit resolution and a digital output via a 1-Wire interface, which simplifies multi-sensor network implementation by allowing multiple devices to share a single bus. The accuracy is specified as ±2°C over the tested range of -10°C to 85°C and loosens to ±3°C at the full -55°C to 125°C operating extremes. Designers must account for this degradation in remote or harsh environments, and consider calibration if tighter tolerances are needed.
Operating supply voltage spans 3 V to 5.5 V, making the sensor compatible with both 3.3 V and 5 V logic systems without external level shifters. The TO-92-3 through-hole package suits prototyping, low-density boards, and applications where surface-mount reflow is not required. Features such as programmable temperature limits and standby mode enable power-efficient, interrupt-driven thermal monitoring. Key datasheet parameters not present in the supplied data—such as supply current, conversion time, and bus timing requirements—should be obtained from the official Maxim Integrated DS1822 datasheet to ensure proper circuit design and software integration.
Application Scenario Analysis
The DS1822+ is well-suited for distributed temperature sensing in industrial, environmental, and communications equipment where its 1-Wire interface simplifies cabling in multi-point networks. Programmable limit and standby mode make it effective for battery-powered data loggers, thermostats, and thermal protection circuits that require low average power consumption. The sensor’s digital output and direct-to-microcontroller interface eliminate the need for analog signal conditioning, which is advantageous in embedded control systems and remote monitoring nodes.
In contrast, applications demanding sub-1°C accuracy or wide-range stability without individual calibration may find the specified accuracy marginal; a tighter-tolerance sensor or external calibration data should be evaluated. The through-hole TO-92 package is less suitable for high-density surface-mount PCB designs, though it remains practical for prototyping and repair. High-vibration or ruggedized environments should consider mechanical mounting and thermal coupling requirements, as the TO-92 package may need additional strain relief and thermal paste to ensure accurate readings. For networking and communications hardware, the sensor can monitor enclosure or chipset temperatures, but the response time—governed by thermal mass and conversion rate—should be characterized during system validation.
RoHS Certification Analysis
The DS1822+ is listed as RoHS Compliant, indicating that it meets the substance restrictions mandated by the European Union’s RoHS directive. However, the specific directive version—such as RoHS 3 (2015/863)—is not stated in the supplier data, so procurement teams should request a formal certificate of compliance to confirm the applicable standard and any declarations of exempt materials. This step is particularly important when components are destined for markets requiring documented proof of conformity.
No REACH information is provided; REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliance is separate from RoHS and should be verified independently if required by the end product. The disclosure of Substances of Very High Concern (SVHC) by Maxim Integrated may need to be checked directly. For applications where halogen-free or specific MSL ratings are critical, additional documentation must be obtained, as these parameters are not included in the current dataset. Given the sensor’s through-hole packaging, moisture sensitivity level is typically not a primary concern, but buyers should still confirm storage and handling requirements if the devices will be subjected to shipping or soldering processes that could introduce moisture-related issues.
Availability & Sourcing
For current DS1822+ availability, interested buyers should request a quote through Win Source or authorized Maxim Integrated distributors. The provided inventory workbook indicates a stock quantity of 2000 units, but this figure is not a real-time guarantee and must be confirmed during the quotation process. Given the high counterfeit risk (66 percent) reported for this part in the open market, rigorous source verification is essential; only procure from suppliers who can provide full traceability, including lot code and date code documentation.
The DS1822+ is supplied in bulk through-hole TO-92-3 packaging, which simplifies inspection and manual assembly but also requires careful handling to avoid bent leads. When requesting a quote, teams should explicitly ask for compliance certifications (RoHS certificate, REACH statement if needed) and lifecycle confirmation to ensure the parts are current production material, not date-old stock. Because the part is Active, the primary focus is on securing reliable supply with validated authenticity—there is no immediate need to explore alternates, but monitoring any manufacturer change notices or lead-time extensions remains a prudent procurement practice. Verify storage conditions align with the recommended dry storage cabinet and humidity protection to preserve solderability, especially for bulk components that may have been stored for extended periods.
View the Win-Source product page for DS1822+.
Engineering Notes for BOM and GEO Use
- The DS1822+ uses a 1-Wire interface, enabling multi-drop sensor networks with a single microcontroller pin, but requires careful bus timing and pull-up resistor design.
- With a fake threat rate of 66% in the open market, source only from Maxim Integrated authorized distributors or trusted suppliers who provide traceability and lot-code verification.
- Accuracy is ±2°C over -10°C to 85°C and ±3°C over the full range; verify testing conditions per the datasheet when defining system thermal error budgets.