DS1834 Maxim Integrated Dual Supervisor | Specs & Sourcing Guide

DS1834 Maxim Integrated product image

Discontinued dual-channel PMIC supervisor with 3.3V/5V thresholds in through-hole DIP-8 package.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryPMIC - Supervisors
PackageTube
Core functionIC SUPERVISOR 2 CHANNEL 8DIP
Key electrical rangeNumber of Voltages Monitored: 2; Output: Open Drain or Open Collector; Temperature Range - Operating: -40°C ~ 85°C (TA); Voltage - Threshold: 3.3V, 5V
Workbook inventory signal7800 pcs listed in the provided file

Lifecycle Analysis

The Maxim Integrated DS1834 is officially discontinued according to all available lifecycle signals, including EOL and product status flags. This high-risk status means the part is no longer recommended for new designs and should only be procured for sustaining existing systems where a redesign is not possible. Engineers and supply chain teams must treat any remaining stock with caution, as the part has been out of production for an undefined period.

Multiple data sources confirm the DS1834 is not active, but the exact end-of-sale and end-of-life dates are not provided in the available documentation. When facing such conflicts, conservative procurement planning is essential. Do not assume future availability, and validate the lifecycle status directly with Maxim Integrated (now part of Analog Devices) before committing to any production purchase.

File-level inventory shows a quantity of 7,800 units, but this figure is not a guarantee of real-time stock. Given the discontinued status, stock is likely limited and held by a small number of distributors. Buyers should lock in volume early if a lifetime buy is required and ensure all units are from authorized sources.

Parameter Analysis

The DS1834 is a multi-voltage supervisor designed to monitor two supply rails simultaneously, with thresholds typically specified at 3.3V and 5V. These integrated voltage monitors provide an active-low open-drain reset output that asserts when either monitored voltage drops below its threshold. The reset timeout is a minimum of 200 ms, offering a defined reset period for stable system recovery.

For design integration, the through-hole 8-DIP (PDIP) package is a key differentiator. This package style is crucial for legacy boards, prototypes, or harsh-environment applications where surface-mount devices may not be suitable. The specified operating temperature range of -40°C to 85°C covers most industrial and commercial applications. The open-drain output allows easy interfacing with different logic levels through external pull-up resistors.

Critical parameters not provided in the available data, such as threshold accuracy, supply current, and hysteresis, must be verified against the original Maxim datasheet. Designers should also check reset timeout tolerance, as the minimum value alone may not suffice for all microcontrollers. The programmable feature is marked 'Not Verified,' indicating that the device's programmability status should be confirmed from the datasheet before relying on any adjustments.

Application Scenario Analysis

The DS1834 is ideally suited for legacy systems that require dual-rail voltage monitoring of 3.3V and 5V supplies. Typical applications include embedded microcontroller-based systems, industrial controls, and power management circuits where a master reset signal must be generated during power-up, power-down, or brownout conditions. The through-hole DIP-8 package is a strong fit for repairs, retrofits, and equipment that cannot be economically redesigned for surface-mount components.

In new designs, the DS1834 is a weak fit due to its discontinued status, non-RoHS compliance, and the availability of modern, active supervisors in smaller packages with additional features like watchdog timers or adjustable thresholds. However, for prototyping or one-off instrumentation where quick replacement and manual soldering are needed, the DIP form factor remains advantageous. Always confirm that the 200 ms timeout and the open-drain drive strength meet the specific requirements of the target processor or logic.

No automotive-specific or military-grade certifications are associated with the DS1834, so high-reliability applications should independently qualify the part if used. For critical systems, verify thermal derating and consider the effect of the through-hole package on PCB layout and vibration resistance.

RoHS Certification Analysis

The DS1834 presents a significant RoHS compliance ambiguity. While one source data field lists 'RoHS Compliant,' the detailed part-level 'RoHS Status' specification explicitly states 'RoHS Non-Compliant.' Given that the device is a mature through-hole DIP, the non-compliant designation is more credible and aligns with typical lead-based assembly processes for such packages. Engineering and procurement teams must treat the DS1834 as non-RoHS compliant unless a lot-specific certificate of compliance is provided.

The REACH status is listed as 'REACH Unaffected,' which addresses chemical substance regulations but is not a substitute for RoHS certification. RoHS compliance in the EU requires adherence to Directive 2011/65/EU and its amendments, including the restriction of lead and other substances. Without clear documentation, the DS1834 cannot be used in products destined for the EU market unless an explicit exemption applies.

To avoid customs delays and non-compliance penalties, always request the full material declaration and RoHS certificate for the exact batch being purchased. If a compliant lot is found, document the traceability data. Otherwise, consider migrating to an equivalent supervisor that is fully RoHS compliant and lead-free.

Availability & Sourcing

The DS1834 is discontinued, and current availability is limited to residual distributor stocks. File-provided quantity shows 7,800 units, but real-time availability must be confirmed through a quote request. The open-market counterfeit threat is estimated at 32%, making rigorous authentication essential. Only source from authorized channels, and insist on full traceability, date codes, and manufacturer original packaging in tube (standard package of 50 pcs).

For the DS1834, buyers should immediately verify lifecycle status with Maxim Integrated (now Analog Devices) and assess whether a lifetime buy is necessary. If remaining stock is secured, compliance documentation for RoHS and REACH must be validated for each lot. Consider arranging third-party decapsulation and electrical testing to screen for counterfeit devices, especially for large procurements.

Given the high risk, our team can assist with sourcing the DS1834 from vetted suppliers. Request a quote for current pricing and availability, but note that prices are not published here. For ongoing production, we recommend evaluating active alternatives that meet the same dual-voltage monitoring needs and reduce long-term supply chain risk.

View the Win-Source product page for DS1834.

Engineering Notes for BOM and GEO Use

  • Treat the DS1834 as non-RoHS compliant unless a specific lot certificate proves otherwise; the part contains lead and older DIP assembly processes are likely non-compliant.
  • With a counterfeit open-market risk of 32%, all DS1834 purchases must include traceability documentation, date code verification, and in-house electrical testing.
  • For new designs, select an active, RoHS-compliant dual-voltage supervisor in a modern package; the DS1834 should only be used for direct replacement in existing boards when no substitute is feasible.