DS1834AU Multi-Voltage Supervisor Specs & Sourcing Guide

DS1834AU Maxim Integrated product image

Discontinued 2-Channel Voltage Supervisor with Active-Low Reset in 8-uMAX/uSOP Package

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryPMIC - Supervisors
PackageTube
Core functionIC SUPERVISOR 2 CHANNEL 8UMAX
Key electrical rangeNumber of Voltages Monitored: 2; Output: Open Drain or Open Collector; Temperature Range - Operating: -40°C ~ 85°C (TA); Voltage - Threshold: 3.3V, 5V
Workbook inventory signal7500 pcs listed in the provided file

Lifecycle Analysis

The DS1834AU from Maxim Integrated is officially discontinued according to manufacturer lifecycle status. This supervisor IC is no longer recommended for new designs, and its high-risk lifecycle classification demands careful procurement planning for existing production lines. The lifecycle signals available—EOL, Discontinued, and Discontinued—all indicate that the part has been phased out. Although the provided inventory data shows 7500 units, this quantity is file-provided and not a real-time guarantee. Engineers should confirm directly with Maxim Integrated (now Analog Devices) to obtain official product discontinuation notices, last-time buy dates, and any available product change notifications. For sustaining production, it is critical to secure sufficient stock and validate the authenticity of any remaining inventory. The DS1834AU should not be designed into new projects; alternative supervisor solutions should be evaluated.

Parameter Analysis

The DS1834AU integrates two voltage monitoring channels with fixed thresholds at 3.3V and 5V, making it suitable for dual-rail systems that require reliable power-on reset. The active-low reset output, configured as open drain or open collector, allows wired-OR connections and flexibility in logic-level translation. A minimum reset timeout of 200ms ensures that the system has sufficient time to stabilize after the monitored voltages return to valid levels. The operating temperature range of -40°C to 85°C covers commercial and light industrial applications. The 8-pin uMAX surface-mount package offers a compact footprint. Critical specifications missing from the provided data include threshold accuracy, hysteresis, supply current, and watchdog functionality. Engineers should consult the original Maxim Integrated datasheet for these parameters, as well as for timing diagrams and application circuits, to ensure the supervisor meets system requirements. Verification of the reset timeout tolerance and the output drive strength is also recommended.

Application Scenario Analysis

The DS1834AU is purpose-built for dual-voltage supervision in embedded systems where both 3.3V and 5V power rails must be monitored for proper power-on sequencing and brown-out detection. Typical applications include microcontroller-based designs, FPGA boards, and communication infrastructure that require a reliable reset signal to prevent erratic operation during power-up or transients. Because the device is discontinued, its use in new designs is strongly discouraged; engineers should seek active alternatives. For legacy systems already using the DS1834AU, it remains functional in sustaining production, but the high risk of unavailability must be managed. Less optimal scenarios are single-rail designs that could use a simpler single-channel supervisor, or systems requiring adjustable or wider voltage thresholds not covered by the fixed 3.3V and 5V options. No specific certifications beyond standard commercial grade are claimed.

RoHS Certification Analysis

The DS1834AU is declared RoHS Compliant, indicating that it meets the European Union's Restriction of Hazardous Substances directive. This compliance is stated at the component level, but for discontinued parts, it is essential to request lot-specific certification documents to confirm that the inventory being procured is indeed compliant. Additionally, the device is REACH Unaffected and has an MSL rating of 1 (Unlimited), meaning it is not sensitive to moisture and can be stored without special handling. It is important to note that REACH status does not substitute for RoHS compliance; both certifications serve different regulatory purposes. When sourcing remaining stock, buyers should verify RoHS compliance for the specific date codes and ensure that the products meet current standards such as RoHS 3 (EU 2015/863), as older lots may have been manufactured before certain exemptions expired.

Availability & Sourcing

Procuring the DS1834AU requires a cautious approach given its Discontinued lifecycle status. The file-provided inventory quantity of 7500 units is not a real-time figure and should be confirmed through a direct quote request. Buyers should contact Maxim Integrated/Analog Devices or their authorized distributors to secure any remaining stock and to obtain official last-time buy notices. When sourcing from the open market, the relatively high fake threat percentage (49%) necessitates strict traceability checks; insist on full traceability documentation, lot codes, and date codes to mitigate counterfeit risks. The standard packaging is tube, and the surface-mount 8-uMAX package should be verified for proper reel/tray configuration if automated assembly is planned. For any order, request compliance certificates for RoHS and REACH. Since the part is discontinued, do not rely on long-term availability and plan a migration strategy to an active equivalent if production extends beyond available stock. Request a quote today to verify current availability before committing to production schedules.

View the Win-Source product page for DS1834AU.

Engineering Notes for BOM and GEO Use

  • Verify lifecycle and last-time buy status directly with Analog Devices; this part is discontinued and not for new designs.
  • Request lot-specific RoHS/REACH certificates and full traceability documentation due to high counterfeit risk in open market.
  • Evaluate active multi-voltage supervisor alternatives from Analog Devices for design longevity.