DS1852B-000 by Maxim Integrated: Specs & Sourcing Guide

DS1852B-000 Maxim Integrated product image

Discontinued Maxim Integrated specialized interface IC with 2-Wire and monitoring applications

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Specialized
PackageTray
Core functionIC INTERFACE SPECIALIZED 25BGA
Key electrical rangeVoltage - Supply: 2.7V ~ 5.5V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS1852B-000 is listed as Discontinued across all available lifecycle signals, including manufacturer product status and lifecycle fields. This consistent indication means the part is no longer manufactured and is not recommended for new designs. For existing production, engineers must treat this as an end-of-life component with high procurement risk.

Given the discontinued status, any remaining stock is likely limited to independent distributors or unused inventory. A file-provided quantity of 1 unit is noted but must be verified with the supplier, as it is not a real-time guarantee. No last-time-buy or end-of-life notice dates were provided, so direct confirmation with Maxim Integrated or an authorized distributor is essential.

To mitigate risk, immediate action should include securing available stock, verifying authenticity, and evaluating a migration path to a functional replacement. Design teams should not expect long-term availability and should plan for qualification of an alternative part as soon as possible.

Parameter Analysis

The DS1852B-000 operates over a 2.7V to 5.5V supply range, making it compatible with both 3.3V and 5V logic systems. Its 2-Wire interface, typically I2C, enables simple multi-device bus communication for configuration and data readback. The surface-mount 25-CSBGA (5x5) package requires careful PCB layout and controlled soldering profiles due to the ball grid array footprint.

MSL Level 3 indicates a moisture sensitivity level with a 168-hour floor life after opening the sealed package, demanding strict handling procedures to avoid package damage during reflow. The specified application field of 'Monitors' suggests the part was designed for supervisory or sensor-monitoring tasks, though exact internal functionality is not detailed beyond its interface specialization.

Key missing parameters from the supplied data include electrical characteristics such as current consumption, I2C speed, resolution, and internal register definitions. Engineers should refer to the manufacturer’s datasheet for these details, as they are critical for verifying compatibility in existing designs or assessing replacement options. The limited data underscores the need for full documentation before relying on this part for any application.

Application Scenario Analysis

Given the generic description as a specialized interface IC with a 2-Wire bus and monitoring application field, the DS1852B-000 is best suited for optical transceiver monitoring and control, such as in SFP or XFP modules, where it likely managed temperature, voltage, and bias supervision. This aligns with Maxim Integrated’s historical product families for fiber-optic modules.

It may also have been used in other embedded systems requiring a simple two-wire monitor for parameters like voltage rails or thermal sensors. However, the discontinued status makes it unsuitable for new optical module designs, where alternative active parts with similar interfaces should be sourced.

In legacy equipment, this IC could still be viable for repair or small-scale production if authentic stock is available. Weak-fit scenarios include applications where a more modern, lower-power, or higher-resolution monitor is required; the lack of detailed datasheets for the DS1852B-000 may hinder integration in new designs even for evaluation.

RoHS Certification Analysis

The DS1852B-000 is marked as RoHS Compliant, indicating it meets the substance restrictions of the EU RoHS directive. However, the specific directive revision (e.g., RoHS 3, EU 2015/863) is not explicitly stated, so compliance is assumed to current European environmental standards for electronic equipment.

No exemptions are listed in the available data. For discontinued components, RoHS compliance is often certified at the product family level, and the actual remaining stock may have been manufactured under an earlier revision. Therefore, procurement teams should request a Certificate of Compliance or RoHS test report tied to the specific date/lot codes of any purchased units.

The REACH status of 'unaffected' is noted separately; it covers registration of chemical substances and does not substitute for RoHS documentation. When sourcing from independent distributors, verifying RoHS status for the specific lot is a critical step to ensure market access, especially for EU-bound products.

Availability & Sourcing

As a discontinued device, the DS1852B-000 is no longer available through authorized Maxim Integrated distribution channels. Sourcing must rely on independent distributors or surplus stock, where a file-provided quantity of 1 unit was noted—this should be treated as a tentative indication, not a real-time inventory guarantee.

The reported 44% fake threat rate in the open market for this part number underscores the high risk of counterfeit components. Strict authentication measures are recommended: request photographs of the lot, date codes, and evidence of moisture-sensitive handling, and consider third-party testing for electrical and physical conformity.

For any purchase, obtain a Certificate of Conformance and proof of RoHS compliance tied to the specific batch. Since the part is obsolete, buyers should also verify the lifecycle status directly with Maxim Integrated to confirm there are no remaining factory stock or last-time-buy windows. For new production, engineers should immediately qualify a replacement part from an authorized source, and only use the DS1852B-000 for short-term maintenance of legacy systems after rigorous verification.

View the Win-Source product page for DS1852B-000.

Engineering Notes for BOM and GEO Use

  • Verify discontinued status and last-time-buy dates directly with Maxim Integrated before committing to production.
  • MSL Level 3 (168-hour floor life) requires controlled storage and handling to prevent moisture damage during assembly.
  • 44% fake threat rate in the open market demands authorized sourcing and comprehensive traceability testing.