Maxim Integrated DS18S20+PAR Temperature Sensor Specs & Sourcing Guide

DS18S20+PAR Maxim Integrated product image

Maxim Integrated DS18S20+PAR active digital temperature sensor with 1-Wire interface, TO-92-3 through-hole package.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryTemperature Sensors - Analog and Digital Output
PackageTO-226-3, TO-92-3 (TO-226AA)
Core functionSENSOR DIGITAL -55C-125C TO92-3
Key electrical rangeOutput Type: 1-Wire®; Sensing Temperature - Local: -55°C ~ 125°C; Supply and Demand Status: Shortage; Temperature Range - Operating: -55°C ~ 125°C
Workbook inventory signal2997 pcs listed in the provided file

Lifecycle Analysis

The DS18S20+PAR from Maxim Integrated is currently at an Active lifecycle status based on provided signals. Active parts are in full production and recommended for both new designs and ongoing manufacturing. Engineering teams can proceed with qualification, knowing that the manufacturer continues to produce and distribute the device.

The risk level is low because there are no conflicting lifecycle signals such as NRND or EOL notices. However, it is good practice to periodically revalidate the status through Maxim Integrated's official product pages or authorized distributors. The file-provided quantity of 2997 units is a point-in-time snapshot and should not replace real-time inventory checks. Sourcing teams should verify current lead times and production continuity directly with Maxim Integrated or authorized channels.

Parameter Analysis

Key parameters for the DS18S20+PAR include its 1-Wire digital output, a local sensing range of -55°C to 125°C, and a 9-bit resolution that yields steps of 0.5°C. The accuracy is specified as ±0.5°C within -10°C to 85°C, widening to ±2°C at the temperature extremes. The supply voltage spans 3V to 5.5V, making the sensor compatible with common 3.3V and 5V MCU systems. The through-hole TO-92-3 package supports breadboarding and manual assembly.

For design-in decisions, the 1-Wire protocol reduces pin count and simplifies harness wiring in multi-sensor arrays. The programmable limit and standby mode features help in power-sensitive applications. Items not provided in the source data but essential to verify from the official datasheet include conversion time, supply current during active and standby states, ESD tolerance, and long-term stability. Without these, the sensor's suitability for battery-operated or high-speed scanning applications cannot be fully assessed.

Application Scenario Analysis

The DS18S20+PAR is well-suited for industrial equipment, HVAC systems, cold chain monitors, and any embedded application requiring local temperature measurement with minimal wiring. The 1-Wire interface makes it attractive when multiple sensors must be placed along a single bus, such as in server room thermal mapping or enclosure monitoring. Programmable limits can trigger alarms in the host controller without constant polling.

Weak-fit scenarios include designs that demand resolution finer than 0.5°C or accuracy beyond ±0.5°C over a broader range. The through-hole TO-92 package may be less ideal for high-vibration environments or space-constrained SMT assembly lines. Battery-powered applications should verify the standby current and conversion time from the datasheet because the source data does not confirm ultra-low-power operation. Additionally, the Supply and Demand Status is listed as "Shortage," so project timelines that depend on immediate large-volume availability should include buffer stock or alternative parts.

RoHS Certification Analysis

The DS18S20+PAR is listed as RoHS Compliant in the supplier data. This suggests the device meets the EU Restriction of Hazardous Substances directive. However, the data does not specify which revision of the directive applies, nor does it explicitly confirm REACH compliance. For regulatory documentation, procurement should request the manufacturer's RoHS certificate that references the specific directive version, typically EU 2015/863 for RoHS 3.

Even when a part is marked RoHS Compliant, there is a possibility of lot-level exemptions in materials such as lead in glass or ceramics. Engineering teams should confirm with Maxim Integrated that the TO-92-3 package is fully compliant without exemptions and that the certificate covers the specific date code or lot being procured. Without additional compliance signals like halogen-free or MSL ratings, it is advisable to treat the RoHS claim at face value while seeking full documentation before production commitment.

Availability & Sourcing

As an Active part, the Maxim Integrated DS18S20+PAR is generally available through standard distribution channels. The source data includes a file-provided quantity of 2997 units, but this is a snapshot and does not reflect real-time live inventory. Sourcing teams should request a quote to obtain current pricing, lead times, and lot-specific availability. The Supply and Demand Status indicated as "Shortage" suggests that demand may currently exceed supply, so securing inventory early or coordinating with authorized distributors is recommended.

When procuring the DS18S20+PAR, verify traceability through date codes and lot codes to guard against counterfeit risks. Request RoHS compliance certificates and confirm the lifecycle status with Maxim Integrated to ensure alignment with the Active designation. For new designs, consider evaluating Maxim Integrated's full 1-Wire temperature sensor portfolio to identify potential drop-in alternatives that may offer better lead times or future-proofing if supply constraints tighten.

View the Win-Source product page for DS18S20+PAR.

Engineering Notes for BOM and GEO Use

  • The 1-Wire interface allows multiple DS18S20+PAR sensors on a single bus, reducing wiring complexity in multi-point temperature monitoring.
  • 9-bit resolution provides an LSB of 0.5°C; verify that the ±0.5°C accuracy over -10°C to 85°C meets your application requirements across the full -55°C to 125°C range.
  • Through-hole TO-92-3 package is convenient for prototyping, but ensure proper thermal coupling to the measured surface to avoid measurement lag.