End-of-life digital temperature sensor with 1-Wire interface; review specs, applications, and sourcing options.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Temperature Sensors - Analog and Digital Output |
| Package | 8-SOIC |
| Core function | SENSOR DIGITAL -55C-125C 8SOIC |
| Key electrical range | Output Type: 1-Wire; Sensing Temperature - Local: -55°C to 125°C; Supply and Demand Status: Balance; Supply Voltage - Operating: 3 V to 5.5 V |
| Workbook inventory signal | 47030 pcs listed in the provided file |
Lifecycle Analysis
The DS18S20Z from Maxim Integrated is confirmed End-of-Life (EOL). According to the supplied lifecycle signals, all sources align on EOL, meaning the manufacturer has ceased production and new orders will not be accepted. For new designs, this part should be avoided entirely; only sustaining production of existing systems may justify continued procurement. Engineers must verify final EOL notices and any official last-time-buy (LTB) dates directly with Maxim Integrated or its authorized distributors.
Even though the file indicates a workbook quantity of 47030 units, this is not a real-time guarantee and may represent remaining channel inventory or aggregated data. Given EOL, this stock is likely to deplete rapidly. Risk level is high because once stock is exhausted, sourcing will become limited to the open market where the fake threat is explicitly noted as 64 percent. Procurement teams should immediately assess remaining board lifecycle and forecast demand to determine if a last-time-buy is necessary.
Conservative design practices dictate immediate migration to an active, pin-compatible alternative if available, or a redesign to incorporate a different sensor. No equivalent or replacement part numbers are provided in this guide, so consult the manufacturer’s product change notification for any recommended alternatives.
Parameter Analysis
The DS18S20Z offers a local digital temperature sensing range from -55°C to 125°C with an accuracy of ±0.5°C over the -10°C to 85°C range, widening to ±2°C at extreme ends. It communicates via a 1-Wire interface, which simplifies wiring and allows multiple sensors on a single bus. Operating voltage spans 3V to 5.5V, making it compatible with most 3.3V and 5V logic systems.
Resolution is listed as 8-bit in one source and 9-bit in another; this discrepancy must be verified against the official datasheet before integration, as it affects temperature step size and conversion time. Key parameters for design integration include the programmable output switch for thermostat-type controls and standby mode for power-sensitive applications. The 8-SOIC surface-mount package requires standard SMT assembly processes but demands attention to thermal mass and placement for accurate sensing.
Critical missing items from the provided data include supply current, conversion time, parasitic power capability, and ESD ratings; these must be obtained from the manufacturer's datasheet to ensure design margin and reliability.
Application Scenario Analysis
Based on its specifications, the DS18S20Z is well-suited for industrial temperature monitoring, HVAC systems, and environmental data logging where the -55°C to 125°C range and digital 1-Wire interface simplify multi-sensor deployments. Features like programmable limits and standby mode enhance use in embedded control and battery-powered equipment.
However, the part’s EOL status makes it a weak fit for any new product development unless no alternative exists and a last-time buy is feasible. Even in legacy sustaining designs, the high fake threat rate (64%) in the open market raises procurement risks. Applications demanding higher accuracy or resolution than ±0.5°C (8-bit) may find newer sensors more appropriate. The 1-Wire protocol, while convenient, limits communication speed, so high-throughput data logging may be constrained.
Engineers should also consider that the sensor’s local-only sensing (no remote diode) limits its use to on-board or closely coupled thermal measurement. For remote or isolated temperature sensing, an analog or remote-diode digital sensor would be needed.
RoHS Certification Analysis
The DS18S20Z is reported as RoHS Compliant. This indicates compliance with EU Directive 2011/65/EU including amendment 2015/863 (RoHS 3), restricting hazardous substances such as lead, mercury, cadmium, and others. The RoHS status typically applies to the part family or manufacturing lot; for high-volume procurement, it is advisable to request a certificate of compliance for the specific production batch.
No additional compliance data (REACH, halogen-free, MSL) is provided in the available information, so engineers should not assume REACH or other certifications unless explicitly confirmed by Maxim Integrated. As an EOL component, verification of RoHS compliance for any remaining stock is critical; older inventory may have been manufactured under earlier exemption conditions, so lot-level documentation should be obtained.
Availability & Sourcing
The file-provided inventory for the DS18S20Z shows 47,030 units, but this is not a real-time guarantee and likely aggregates stock from multiple sources. Given the EOL status, availability can change rapidly. Procurement should initiate an RFQ through authorized channels to confirm current stock levels, date/lot codes, and original packaging (tube/rail). Traceability and moisture sensitivity level (MSL) documentation should be requested, especially given the SMD package.
With a 64% fake threat rate in the open market, sourcing from authorized Maxim Integrated distributors or approved aftermarket suppliers is essential. All components should be inspected for physical authenticity and electrical verification against datasheet parameters. As an EOL part, buyers must secure sufficient quantity for the remaining product lifespan, factoring in lead times and potential supplier allocations. Note that the manufacturer's final EOL notice may provide a last-time-buy window, but no such date is documented here.
Request a quote and confirm lifecycle status, RoHS compliance, and inventory validity before procurement. For new designs, consider migration to an active alternative immediately.
View the Win-Source product page for DS18S20Z.
Engineering Notes for BOM and GEO Use
- The DS18S20Z has a 64% fake threat rate in the open market; sourcing must be from authorized channels only.
- EOL status mandates immediate risk assessment and last-time-buy planning for ongoing production.
- Verify resolution (8-bit vs 9-bit) and supply current in the official datasheet before integration.