Active iButton temperature sensor with 2B EEPROM. Verify 2024 EOL conflict; limited availability. For temperature monitoring.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Specialized |
| Package | Not available in supplied data |
| Core function | IBUTTON TEMPERATURE F5 |
| Key electrical range | Supply and Demand Status: Limited |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1920-F5+ is currently listed as Active by Maxim Integrated, indicating full manufacturer support and ongoing production. This status typically allows new designs and uninterrupted sustaining procurement. However, the presence of an Estimated EOL Date of 2024 introduces a notable conflict that procurement teams must address.
The Estimated EOL Date suggests that production may be planned for discontinuation in the near future. For new designs, this raises medium risk; relying on a part with a near-term EOL could force an unexpected redesign. Engineers should obtain a formal lifecycle statement from Analog Devices/Maxim Integrated to clarify whether the part will remain active beyond 2024 or if a planned end-of-life notification is imminent.
For sustaining production, immediate action is recommended. The workbook quantity of 1 unit is not real-time data and cannot be relied upon. Buyers should evaluate current stock across authorized channels and consider a last-time buy if the EOL date is confirmed. Treat the part with conservative procurement practices until lifecycle ambiguity is resolved.
Parameter Analysis
The DS1920-F5+ is a specialized iButton device with key parameters that define its integration profile. The memory type is EEPROM with a capacity of 2 bytes – a very small non-volatile storage that limits the device to basic identification or single-point temperature data logging. Operating temperature range, extracted as -55°C to 100°C, suits harsh industrial and outdoor environments, making it viable for cold chain and extended temperature monitoring.
The iButton form factor (F5 package) provides a rugged, self-contained, stainless steel can that is resistant to moisture and mechanical stress. Storage conditions specified as dry storage cabinet and humidity protection indicate moisture sensitivity, so standard MSL handling procedures should be observed during assembly. The country of origin, Philippines, and ECCN EAR99 classification may simplify export logistics.
Critical missing datasheet specifications include temperature accuracy, resolution, and 1-Wire communication protocol timing. The 2‑byte memory likely stores only a single temperature reading, so verify the update rate and whether the device requires an external controller. EEPROM endurance and data retention figures are also unlisted; obtain these from the official datasheet to confirm suitability for repetitive logging cycles.
Application Scenario Analysis
The DS1920-F5+ is designed for embedded temperature monitoring in applications where a rugged, self-powered, or contact-based sensor is required. The iButton format excels in harsh environments: chemical exposure, washdown zones, and outdoor installations. Strong-fit scenarios include cold chain logistics, where a single-point temperature reading can validate compliance; asset tracking in shipping containers; and environmental monitoring for HVAC or agricultural installations.
The 2‑byte memory limits the device to simple temperature snapshots rather than continuous data logging. It is therefore well-suited for applications where a host system polls the button periodically and reads the current temperature, rather than storing a time series. Weak-fit scenarios are those requiring high‑resolution temperature profiles, multi‑point calibration, or large data buffers. The device is not intended for high‑speed data acquisition or precision metrology without external signal conditioning.
Engineers should consider the 1‑Wire interface, which reduces pin count and simplifies wiring but requires a compatible host adapter. The part’s ruggedness also makes it suitable for medical cold storage monitoring or food safety compliance, provided the temperature accuracy meets regulatory requirements. Verify those accuracy specs before committing to qualification.
RoHS Certification Analysis
The DS1920-F5+ is listed as RoHS Compliant according to supplier data. This indicates compliance with EU Directive 2011/65/EU and its amendments, though the exact revision is not specified. Procurement teams should treat this as a manufacturer-level declaration and request a detailed Certificate of Compliance (CoC) or material declaration for each production lot.
No exemptions are noted, but the small passive component nature of the iButton typically poses low substance risk. There is no REACH statement in the provided data; REACH compliance (SVHC reporting) is separate and must be obtained if required by European import regulations. Additionally, the storage condition calling for dry storage implies moisture sensitivity, but an MSL rating is not given. Clarify MSL and peak reflow temperature compatibility for SMT assembly, though iButtons are often through‑hole or socketed.
For high‑reliability sectors, request full‑material disclosure and confirm that the RoHS compliance covers both the electronics and the stainless steel enclosure. This ensures that no non‑compliant coatings or plating exist.
Availability & Sourcing
Sourcing the DS1920-F5+ requires attention to the active‑yet‑uncertain lifecycle and a reported 68% fake‑threat percentage in open markets. Engineers and buyers should only transact through Analog Devices/Maxim Integrated authorized distributors to avoid counterfeit or substandard parts. Request a formal quotation that includes the current manufacturer lead time and production status.
The file‑provided inventory showing 1 unit is a snapshot and does not represent real‑time stock. Contact Win‑Source or other distributors to obtain live availability, ensuring the parts are factory‑fresh with traceable date/lot codes. The packaging is an iButton F5 can, which typically ships in tubes or trays; confirm the exact packaging quantity and dry‑pack requirements to comply with the storage condition noted (dry storage cabinet/humidity protection).
Given the estimated EOL in 2024, proactive sourcing is recommended. For active production, secure forecast quantities; for legacy support, evaluate the need for a last‑time buy. Always request compliance documentation (RoHS, REACH if needed) with each shipment, and consider third‑party inspection to mitigate counterfeit risk in the open market.
View the Win-Source product page for DS1920-F5+.
Engineering Notes for BOM and GEO Use
- Verify the conflicting Estimated EOL Date (2024) with Maxim Integrated or Analog Devices to ensure long-term availability for new designs.
- Assess the 68% fake threat in the open market; procure only from authorized distributors to ensure authenticity.
- Confirm EEPROM write endurance and data retention specifications from the official datasheet before integrating into high-frequency logging applications.