Maxim Integrated DS2114Z SCSI Terminator Specs & Sourcing Guide

DS2114Z Maxim Integrated product image

Single-ended SCSI terminator for parallel bus signal integrity. EOL status demands careful sourcing and compliance review.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Signal Terminators
Package16-SO
Core functionIC TERM SCSI 2% 150MIL 16-SOIC
Key electrical rangeSupply and Demand Status: Limited; Supply Voltage - Operating: 4 V to 5.5 V; Temperature Range - Operating: 0°C to 70°C
Workbook inventory signal2000 pcs listed in the provided file

Lifecycle Analysis

The DS2114Z from Maxim Integrated is classified as End-of-Life (EOL) with high risk. This status indicates the component has been discontinued by the manufacturer and is no longer recommended for new designs. EOL parts may still be available through remaining inventory channels, but future supply is not guaranteed.

Engineers and buyers should treat the DS2114Z as a legacy component and avoid incorporating it into new production designs. For existing systems, it is critical to assess current inventory levels and plan for a last-time buy if necessary. The supplied file indicates a workbook quantity of 2000 units, but real-time availability may vary; always confirm with the supplier.

Lifecycle data shows no conflicting signals — all available sources confirm EOL. To mitigate risk, verify the manufacturer’s official discontinuation notice and explore compatible alternatives or design revisions for sustained production. Transitioning to an active replacement is strongly recommended.

Parameter Analysis

The DS2114Z is a 9-line SCSI terminator in a 16-SOIC surface-mount package, designed for single-ended (SE) parallel SCSI buses. Key specifications from the available data include an operating voltage range of 4 V to 5.5 V and a temperature range of 0°C to 70°C, making it suitable for standard commercial-grade environments.

The 2% termination accuracy, referenced in the product description, is critical for maintaining signal integrity by matching the characteristic impedance of the SCSI cable. The 9 termination lines correspond to a typical narrow SCSI (8 data bits + parity), and the SE configuration imposes a maximum bus length of about 6 meters. Missing from the data are dynamic parameters such as termination resistance value, capacitance, and power dissipation, which are essential for thermal and signal quality assessments.

Engineers should consult the original Maxim datasheet to verify resistance matching (typically 110 ohms for SE SCSI), leakage current, and response time. For replacement designs, ensure the alternative meets the same electrical and footprint constraints, particularly the 150-mil SOIC width mentioned in the description.

Application Scenario Analysis

The DS2114Z is uniquely suited for legacy SCSI-1, SCSI-2, and Fast SCSI (up to 10 MB/s) parallel interfaces. It finds primary application in industrial equipment, test instrumentation, and legacy computing platforms where SCSI drives, scanners, or tape backup systems are still operational. It can also serve as a terminator for internal SCSI controller cards or external daisy-chained peripherals.

In modern designs, the DS2114Z has weak fit or no applicability. Contemporary systems overwhelmingly use serial interfaces like SAS, SATA, or USB, which do not require passive termination networks. Even within SCSI ecosystems, it is limited to single-ended buses and cannot be used for differential (HVD/LVD) SCSI variants, which dominate in newer or higher-performance implementations.

Before specifying this part for maintenance or repair, confirm that the target bus is narrow 8-bit SE SCSI and that the terminator’s voltage range matches the bus’s TERMPWR supply. For any new development, a migration to a more modern interface or an active terminator in a smaller package may be appropriate.

RoHS Certification Analysis

The RoHS status of the DS2114Z is ambiguous. The top-level compliance block labels the part as ‘RoHS Compliant,’ while the detailed specifications table explicitly states ‘RoHS Non-Compliant.’ This discrepancy requires immediate clarification before procurement.

Without a definitive statement from Maxim Integrated or an authorized distributor, the part should be treated as potentially non-RoHS for regulatory planning. No specific exemptions are noted, and REACH status is not provided. If compliance is mandatory for your application or geographical market, request a lot-specific certificate of compliance from the supplier. The storage condition noted (dry storage cabinet & humidity protection) and raw material description (silicon) do not substitute for official compliance documentation.

For designs that must meet RoHS 3 (EU 2015/863) or similar standards, consider whether lead-free soldering processes are compatible with the 16-SOIC package and whether any available inventory is from compliant production runs. In high-reliability or export-controlled projects, non-compliance could halt production.

Availability & Sourcing

The DS2114Z is an EOL part with high risk, and sourcing must be approached conservatively. The file-provided inventory shows a workbook quantity of 2000 units, but this number is not real-time and may not reflect actual stock. Given the 71% fake threat in the open market, procurement from unauthorized channels is strongly discouraged.

Buyers should request a quote through a verified distributor or the Win-Source RFQ process to obtain current availability, lot/date codes, and traceability documentation. Confirm packaging (Tube/Rail) and storage conditions to ensure component integrity. For EOL parts, emphasize that no further manufacturing is planned, so securing inventory now is critical for long-term support of existing systems.

Before finalizing a purchase, verify RoHS compliance and lifecycle status with the supplier, and inspect for proper manufacturer labeling to avoid counterfeit products. If your design can be modified, consider transitioning to an active replacement part to simplify future sourcing. For immediate needs, request a formal quote to lock in supply.

View the Win-Source product page for DS2114Z.

Engineering Notes for BOM and GEO Use

  • DS2114Z is end-of-life; plan migration for new designs and secure remaining stock for existing systems.
  • RoHS status conflict between top-level and detailed specs; request lot-specific compliance certificates.
  • High counterfeit threat (71% open market) requires sourcing through authorized channels with traceability documentation.