EOL single-chip T1 transceiver with HDLC controller. Verify lifecycle and secure inventory for existing designs.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Interface - Telecom |
| Package | 100-LQFP (14x14) |
| Core function | IC TELECOM INTERFACE 100LQFP |
| Key electrical range | Operating Supply Current: 75mA; Supply and Demand Status: Balance; Supply Voltage - Operating: 3.14 V to 3.47 V; Temperature Range - Operating: 0°C to 70°C |
| Workbook inventory signal | 2280 pcs listed in the provided file |
Lifecycle Analysis
Maxim Integrated (now part of Analog Devices) has marked the DS21352L+ as End-of-Life (EOL). All available lifecycle signals confirm this status, with no conflicting indicators. For engineers, this means the part should not be used in new designs; any existing design must move to a replacement or secure sufficient inventory for the remaining production lifetime.
Procurement teams should immediately engage with authorized distributors to obtain the last-time buy (LTB) schedule, if still active, or locate authorized sources for remaining stock. The supplied inventory file indicates a quantity of 2280 units, but this is not a real-time guarantee and must be verified with the distributor. In a high-fake-threat environment (rated 72%), verifying date/lot codes and traceability becomes critical when sourcing EOL components.
Without an active manufacturer supply, long-term sustainment planning should consider redesign or substitution. Contact Analog Devices for the formal product discontinuance notice (PDN) and any suggested migration paths.
Parameter Analysis
The DS21352L+ is a single-chip transceiver for T1/DSX-1 applications, housed in a 100-LQFP (14x14 mm) surface-mount package. Its operating supply voltage range of 3.14 V to 3.47 V is moderately tight, requiring a well-regulated 3.3V rail with ripple under control to maintain line interface performance. The typical supply current of 75 mA must be accounted for in power budgeting and thermal analysis, especially in dense line-card designs.
The part integrates an HDLC controller, DSX-1 and CSU line build-out generator, and in-band loop code generator/detector, reducing external component count. However, the commercial temperature range (0°C to 70°C) limits deployment to indoor, controlled environments; extended-industrial applications would require an alternative. Engineers should verify critical parameters not listed in the supplied data, such as jitter attenuation specs, exact interface electrical characteristics (e.g., line impedance), and detailed register maps, by consulting the official Maxim datasheet before integration.
Application Scenario Analysis
The DS21352L+ is optimized for T1 (1.544 Mbps) telecommunications interfaces, commonly found in channel service units (CSU), data service units (DSU), multiplexers, and PBX trunk cards. Its integrated HDLC controller suits applications requiring packetized data over T1 links, such as frame relay access devices or legacy router WAN interface cards.
This part is a strong fit for maintaining existing deployed systems or replicating proven designs in low-volume, controlled-environment products. However, its EOL status makes it unsuitable for new high-volume production. The commercial temperature range and high counterfeit risk further weaken its fit for mission-critical or outdoor infrastructure. Engineers should evaluate pin-compatible successors like the DS26518 or newer multi-port framers if a redesign is feasible. For repair or spares, careful authentication is required.
RoHS Certification Analysis
The DS21352L+ is classified as RoHS Compliant according to the data provided. This generally indicates conformity to the EU Restriction of Hazardous Substances Directive (often the latest EU RoHS 3, 2015/863), including lead-free terminations and limiting substances like cadmium, mercury, and phthalates. No specific exemptions were noted in the supplied information.
Since the part is EOL, compliance documentation may be based on original manufacturing records, and recertification for recently procured lots might not be available. Buyers should request a Certificate of Conformance (CoC) or full material declaration from the distributor for each shipment. Note that RoHS compliance does not automatically imply REACH SVHC-free status; that requires separate verification. For international shipments, confirm that the RoHS marking applies to the specific date/lot code, as older non-compliant inventory may still circulate.
Availability & Sourcing
Maxim Integrated's DS21352L+ is marked End-of-Life, making availability highly constrained. The distributor file lists 2280 units in stock, but actual real-time availability can only be confirmed through a quote request. The part is supplied in trays (standard for 100-LQFP), and proper storage conditions (dry cabinet with humidity protection) are specified to maintain solderability.
Given the high open-market counterfeit threat (72%), sourcing from unauthorized channels is strongly discouraged. Engineers and buyers should prioritize authorized distributors with full traceability, request date/lot code verification, and conduct incoming visual and electrical inspections. For production planning, immediately determine last-time buy deadlines and consider lifecycle bridging to a recommended replacement like the DS26518 or DS21354. Contact Analog Devices for PDN documents and replacement guidance. For any remaining stock, request a quote for current availability and compliance paperwork.
View the Win-Source product page for DS21352L+.
Engineering Notes for BOM and GEO Use
- Verify EOL status with Maxim Integrated (now Analog Devices) and evaluate last-time buy opportunities.
- High counterfeit risk (72%) in open market — implement stringent incoming inspection and traceability checks.
- Ensure RoHS compliance documentation aligns with specific lot codes prior to production use.