Single-position gray terminal block with spring cage termination and flange mount.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Amphenol Anytek |
| Category | Terminal Blocks |
| Package | Not available in supplied data |
| Core function | TERM BLK 1POS GRAY |
| Key electrical range | Current Rating: 18A; Nominal current IN - UL: 10A; Supply and Demand Status: Balance; Temperature Range - Operating: -40°C to 115°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS2400108000G from Amphenol Anytek is confirmed Active by multiple lifecycle signals available in the supplied data, with no indication of NRND or discontinuation. This status supports new design wins and stable procurement for production builds.
Low lifecycle risk means engineering teams can confidently include this part in new BOMs, but procurement should still schedule periodic lifecycle reviews directly with the manufacturer. Because lifecycle status can change without notice, subscribing to Amphenol Anytek’s PCN alerts is recommended to catch any transition early.
The file-provided workbook quantity of 1 unit is a point-in-time snapshot and does not represent guaranteed stock levels. For real-time availability, always request a quote through an authorized distributor and confirm the current lifecycle status prior to large-scale procurement.
Parameter Analysis
The DS2400108000G terminal block carries dual ratings: 18 A/400 V per IEC and 10 A/300 V per UL. Designers must match the applicable standard to the end-equipment certification requirements. The lower UL current rating, combined with the 16-28 AWG wire range, sets the upper bound for conductor selection in North American installations.
The spring cage termination style simplifies field wiring and provides vibration resistance, but proper stripping to 9 mm is essential for gas-tight connections. The thermoplastic housing meets UL94 V-0 flammability, which is critical for fire-safety requirements in industrial enclosures. The maximum operating temperature of 115°C allows use near heat sources, but derating may apply if high currents and elevated temperatures coincide.
Missing from the available data are the exact pitch, detailed dimensional drawings, and IEC overvoltage category ratings. Before finalizing the PCB or panel layout, obtain the full datasheet to confirm footprint, clearance, and creepage distances.
Application Scenario Analysis
As a single-position middle-type terminal block, the DS2400108000G serves as a feed-through connection point in control panels, power distribution boards, and building automation systems. Its flange mount feature enables secure fixation to panels, and the gray color coding can match neutral or general-purpose wiring conventions.
This part is a strong fit for applications requiring a compact, single-circuit termination with spring cage reliability, such as connecting field sensors to PLC I/O in industrial machinery. It is less suited for applications needing high-density multi-position blocks, as each position requires a separate unit. Additionally, while spring cage terminations generally handle vibration well, applications with extreme shock or continuous motion may require supplementary strain relief.
The operating range of -40°C to 115°C makes it suitable for outdoor or unheated enclosures, but design-in at temperature extremes should consider current derating and insulation aging. Verify that the thermoplastic material meets long-term thermal requirements for your specific environment.
RoHS Certification Analysis
Amphenol Anytek identifies the DS2400108000G as RoHS Compliant, indicating that it meets the substance restrictions of the EU RoHS directive. The exact directive revision (e.g., 2011/65/EU or 2015/863) is not specified in the provided data; typically, current production of active parts complies with the 2015/863 amendment, but this should be confirmed with the manufacturer.
No specific RoHS exemptions are listed for this terminal block, which suggests that all materials, including the thermoplastic housing, internal spring, and plating, fall within the allowable limits for lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and the four phthalates (DEHP, BBP, DBP, DIBP). However, a formal certificate of compliance should be requested for each production lot to guarantee consistency, especially if the product is destined for the European market.
Note that the provided data does not include REACH, MSL, or halogen-free declarations. While RoHS compliance addresses many environmental concerns, if your application demands REACH or halogen-free status, contact the supplier for additional documentation.
Availability & Sourcing
The DS2400108000G is currently in Active lifecycle status, suggesting straightforward availability through authorized Amphenol Anytek distribution channels. The file-provided inventory shows 1 unit, but this is not a live stock level; real-time quantity must be validated through a quote request.
Procurement teams should be aware that the open-market fake threat level for this part number is reported at 42%, which underscores the importance of sourcing only from franchised distributors or directly from the manufacturer. Request traceability documentation, including date/lot codes and certificates of conformance, to mitigate counterfeit risk. The part is supplied in bulk packaging; verify the exact packaging format (e.g., tape, tray) when placing orders.
For current availability, lead times, and pricing, contact Win Source or your preferred authorized distributor. As this is an Active part, standard ordering and compliance verification practices apply. Always confirm the latest lifecycle status and any PCN notices before committing to high-volume production runs.
View the Win-Source product page for DS2400108000G.
Engineering Notes for BOM and GEO Use
- Confirm the mounting footprint and flange dimensions from the manufacturer datasheet before PCB layout.
- Stripping length is 9 mm; ensure wire preparation adheres to this specification for reliable spring-cage termination.
- At 115°C maximum operating temperature, derate current rating if the assembly will operate in elevated ambient conditions per UL/IEC guidelines.