Interface - Specialized IC by Maxim Integrated, now End-of-Life (EOL). Review lifecycle and sourcing options.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Interface - Specialized |
| Package | 6-LSOJ (0.148", 3.76mm Width) |
| Core function | IC INTERFACE SPECIALIZED 6TSOC |
| Key electrical range | Supply and Demand Status: Limited; Supply Voltage (V): 2.8V ~ 6V |
| Workbook inventory signal | 4000 pcs listed in the provided file |
Lifecycle Analysis
The Maxim Integrated DS2406P has been declared End-of-Life (EOL) by the manufacturer. All lifecycle indicators in the supplied data, including the Excel lifecycle parameter, Lifecycle Status, and Part Status, align with this classification. This means the part is no longer recommended for new designs, and last-time-buy opportunities may have already passed or are extremely limited.
For existing production lines, immediate action is required. Engineers must secure available inventory and validate its authenticity and shelf life. The file-provided quantity of 4000 units suggests some remaining buffer, but this figure is not a real-time guarantee and does not reflect distributor stock or future availability. Without an active procurement window, the risk of depletion is high.
Risk management should include contacting Analog Devices/Maxim Integrated directly for an official EOL notice, final orders timeline, and any supporting documentation. Using this device in new designs carries a high risk of long-term obsolescence and counterfeit intrusion, especially given the 68% counterfeit threat rate in the open market.
Parameter Analysis
The DS2406P operates over a supply voltage range of 2.8V to 6V, making it suitable for battery-powered and loosely regulated systems. Its 1-Wire interface is the primary design constraint: a single data line plus ground handles power and communication, which demands careful PCB routing but reduces pin count. The 6-TSOC (LSOJ) SMD package is compact, with a width of 3.76mm, and the MSL Level 1 (unlimited) rating eases handling and storage.
These parameters are critical for retrofit or repair of legacy 1-Wire networks where pin-for-pin compatibility is mandatory. The voltage range must be de-rated against the system’s worst-case supply, and layout parasitics on the 1-Wire line should be minimized to meet timing requirements. However, many essential electrical specifications are absent from the available data—output drive strength, timing parameters, ESD rating, and temperature range are not provided. These must be verified against the official Maxim datasheet before committing to a board spin.
Additionally, the sourced parameter indicating a 68% counterfeit threat in the open market underscores the need to validate every lot. Parameter consistency (marking, package dimensions, electrical behavior) should be spot-checked against manufacturer documentation to avoid substandard or recycled parts.
Application Scenario Analysis
The DS2406P was originally designed for remote control and remote metering, as identified in the specifications. It fits well in legacy 1-Wire architectures such as access control key readers, environmental sensor nodes, and industrial equipment where a simple, low-speed serial link is sufficient. These applications benefit from the part’s wide supply range and SMD form factor, and many existing installations may still rely on the DS2406P for service and support.
In contrast, this device is a weak fit for new product developments that demand higher data throughput, modern interfaces (I2C, SPI), or guaranteed long-term availability. Its EOL status makes it unsuitable for any design that requires a multi-year production lifecycle. Even in sustaining engineering, the counterfeit risk and dwindling supply can introduce unacceptable field reliability issues.
When evaluating the DS2406P for replacement orders, engineers should treat it as a legacy support option only. Any move to re-spin a product around this part should first consider a drop-in alternative from the manufacturer’s product line or a functional equivalent with confirmed active status.
RoHS Certification Analysis
The DS2406P presents a compliance conflict: the top-level RoHS status is reported as 'RoHS Compliant,' but a deeper specification field explicitly lists 'RoHS Non-Compliant.' This contradictory data makes it impossible to declare the part RoHS compliant from the provided information alone. In regulated environments (EU, China RoHS, etc.), relying on such ambiguous records can lead to non-compliance penalties or shipment rejections.
No additional environmental data is available for REACH, halogen-free, or Pb-free status. The part has an MSL rating of 1 (unlimited), which indicates no special moisture precautions, but that does not address RoHS substance restrictions. The standard to which compliance is referenced is not stated; therefore, it cannot be assumed to meet EU RoHS or any specific exemption.
To resolve this, the procurement team must request the full material declaration or RoHS certificate for the specific lot code being purchased. If the part is confirmed non-compliant, it should only be used where exemptions apply or in non-regulated applications. In all cases, document the compliance status per lot to maintain traceability.
Availability & Sourcing
The Maxim Integrated DS2406P is in End-of-Life status, which constrains availability to remaining channel inventory. The file-provided workbook quantity shows 4000 units, but this is not a live stock indicator and may not reflect current distributor holdings. The supply and demand status is marked 'Limited,' consistent with an obsolete part nearing depletion.
Sourcing must follow a strict RFQ workflow with explicit lifecycle verification. Buyers should request date and lot codes, manufacturer pack quantity (originally 120 per tube), and original packaging confirmation (tube). Given the 68% counterfeit risk, traceability back to Maxim Integrated or an authorized franchise is non-negotiable. Without such traceability, the risk of receiving non-functional or remarked components is extremely high.
For immediate production needs, secure inventory now and store under MSL-1 conditions. For future orders, define a cut-off date for last-time-buy and begin qualification of an alternative part. Always request a quote from trusted suppliers that can provide compliance documentation (RoHS certificate, C of C) and lifecycle-status confirmation. Do not rely on open-market intermediaries without full traceability and quality inspection.
View the Win-Source product page for DS2406P.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance due to conflicting data sources; obtain lot-specific certification or a C of C before relying on RoHS status.
- EOL status and a 68% counterfeit threat require sourcing only through authorized or fully traceable channels; insist on date/lot code verification.
- Confirm supply voltage range (2.8V–6V) and 1-Wire protocol compatibility for legacy designs; initiate migration for all new production.