Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Controllers
Package9-WLP
Core functionIC MASTER I2C-1WIRE 1CH 9-WLP
Key electrical rangeOperating Supply Current: 750μA; Supply and Demand Status: Balance; Supply Voltage - Operating: 2.9 V to 5.5 V; Temperature Range - Operating: -40°C to 85°C
Workbook inventory signal1650 pcs listed in the provided file

Lifecycle Analysis

The DS2482X-101+T from Maxim Integrated is in active lifecycle status according to supplied data. This indicates the part is in full production, supported by the manufacturer, and available for new design-in as well as ongoing production orders. The low risk level reflects no conflicting lifecycle signals such as NRND or EOL notices.

For design teams, active status means the DS2482X-101+T can be confidently integrated into new products without immediate concerns about obsolescence. However, it is advisable to periodically re-check the manufacturer's official product page for any updated lifecycle notices, as status can change. The provided inventory signal of 1650 units in supplier data suggests a healthy pipeline, but real-time stock must be verified before placing orders.

Sustaining production users should maintain communication with authorized distributors to ensure continuous supply. No reported conflicts indicate a strong production future, but standard procurement practices such as securing lifecycle guarantees from franchised sources remain important.

Parameter Analysis

Key parameters for the DS2482X-101+T include its function as an I2C-to-1-Wire bridge, supply voltage range of 2.9V to 5.5V, operating temperature range of -40°C to 85°C, operating supply current of 750µA, and 9-WLP package. The supply voltage range provides flexibility for both 3.3V and 5V system designs, and the low supply current is beneficial for power-sensitive applications.

The 9-WLP package measures approximately 1.53mm x 1.53mm, requiring careful PCB layout to ensure proper thermal management and signal integrity. The industrial temperature range supports most embedded and industrial environments, but designs targeting extended temperatures should verify margin. The 1-Wire protocol support enables communication with a wide array of sensors and memory devices using minimal pin count.

Important missing specification details that should be verified from the official datasheet include I2C interface speed grade, internal voltage reference accuracy, ESD protection ratings, and specific 1-Wire timing parameters. These values are essential for reliable system integration and should be confirmed during design qualification.

Application Scenario Analysis

The DS2482X-101+T is an ideal fit for applications requiring a bridge from an I2C master to a 1-Wire slave network. Strong-fit scenarios include industrial sensor networks, environmental monitoring, equipment authentication, and medical consumable identification where 1-Wire devices like temperature sensors, EEPROMs, or secure authenticators are used. Its low power and compact package suit portable and space-constrained designs.

Weaker-fit scenarios involve systems that require high-speed data transfers beyond typical 1-Wire rates, or those that need multiple 1-Wire channels managed independently without additional software or addressing overhead. While the device is specified for -40°C to 85°C, applications with extreme temperature demands should confirm suitability or consider devices with extended ranges. Additionally, designs that require USB, SPI, or RS-232 bridging would need a different solution.

Engineers should evaluate 1-Wire network size and power delivery requirements, as the DS2482X-101+T provides strong pull-up support but may need external circuitry for complex networks. Overall, it is a well-matched component for standard I2C-to-1-Wire bridging tasks in industrial and commercial products.

RoHS Certification Analysis

The DS2482X-101+T is listed as RoHS Compliant, indicating it does not contain hazardous substances above the thresholds defined by EU directive 2011/65/EU and its amendments. This certification is essential for products sold in the European Union and other regions with similar environmental regulations.

While the RoHS status is declared, additional compliance details such as REACH, MSL (Moisture Sensitivity Level), and halogen-free status are not provided in the available data. REACH compliance is separate from RoHS and addresses different chemical substances, so a REACH certificate should be requested if needed for your product’s regulatory requirements. The MSL rating is important for proper handling and storage of the 9-WLP package during assembly.

Sourcing teams should request the full Material Declaration Data Sheet from Maxim Integrated or authorized distributors to confirm lot-level RoHS compliance and to obtain any exemptions that may apply. The dry storage and humidity protection package mentioned in the data aligns with good handling practices but does not substitute for an official MSL classification.

Availability & Sourcing

The DS2482X-101+T is an active part with a balanced supply and demand status and high popularity according to the provided data. File-based inventory shows 1650 units, but this is not a real-time guarantee and should be validated by requesting a current quote. The component is supplied in reel packaging, suitable for automated assembly.

Given its common-use classification and 35% fake threat in the open market, buyers should source exclusively through authorized Maxim Integrated distributors or reputable suppliers with strong counterfeit mitigation processes. Requesting lot codes, date codes, and traceability documentation is essential to ensure authenticity and to maintain compliance records.

To secure availability, contact Win Source or other franchised channels for a live quotation that includes lead time, quantity in stock, and batch compliance certificates. As an active part, the procurement focus should be on timely ordering and verification of lifecycle and RoHS documentation to safeguard production continuity.

View the Win-Source product page for DS2482X-101+T.

Engineering Notes for BOM and GEO Use

  • Verify operating supply current (750µA) for thermal budget, especially in compact 9-WLP layout.
  • Confirm 1-Wire protocol timing compatibility with target devices.
  • Request lot-level RoHS compliance documentation during procurement.