RS-422/RS-485 Quad Driver Discontinued Part Sourcing Resource
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | Tape & Reel |
| Core function | IC TRANSCEIVER 4/0 16SOIC |
| Key electrical range | Temperature Range - Operating: 0°C ~ 70°C; Voltage - Supply: 4.5V ~ 5.5V |
| Workbook inventory signal | 7540 pcs listed in the provided file |
Lifecycle Analysis
The DS26LS31CMX from Texas Instruments is officially discontinued according to manufacturer data. The lifecycle status is classified as EOL and Discontinued in multiple fields, indicating that the part is no longer in active production. This status means it is unsuitable for new designs; it should only be used to sustain existing systems where a redesign is not feasible.
Engineers must review the manufacturer's official discontinuation notice, including the last-time buy (LTB) date and any recommended replacement products. Since the source data shows conflicting lifecycle signals (EOL vs Discontinued), it is critical to confirm the final lifecycle phase with Texas Instruments to avoid false assumptions about future availability.
Procurement teams should treat any remaining inventory as legacy stock. The file-provided inventory quantity may not reflect real-time availability, and lead times can be unpredictable for discontinued components. Secure known-good stock and evaluate whether a migration to an active alternative is viable before inventory is exhausted.
Parameter Analysis
The DS26LS31CMX is a quad line driver designed for RS-422 and RS-485 differential signaling. It features four driver outputs with no integrated receivers, making it suitable for unidirectional data transmission in balanced communication networks. The device operates from a single 5V supply (4.5V to 5.5V) and is rated for commercial temperature range (0°C to 70°C). The 16-SOIC surface-mount package offers standard footprint for automated assembly.
Key missing datasheet parameters include maximum data rate, output current capability, propagation delay, and ESD protection levels. These specifications are critical for determining signal integrity, cable drive distance, and robustness in industrial environments. Without them, designers must consult the full manufacturer datasheet to verify that the part meets the required timing and drive strength for their application.
The 4/0 driver/receiver count confirms that this is a transmit-only interface solution. When integrating this into legacy designs, verify that the supply voltage tolerance aligns with your system's power rail, as the narrow 5V range may require additional regulation compared to modern wide-supply devices.
Application Scenario Analysis
The DS26LS31CMX fits well in legacy industrial automation equipment such as programmable logic controllers (PLCs), motor drives, and factory-floor data links that use RS-422 or RS-485 multidrop networks. Its quad driver configuration and 5V operation are typical of 1990s-2000s interface designs, making it a direct fit for repairing or extending the life of older control systems.
This part is less suited for new product developments where availability, modern ESD protection, low-power operation, and extended temperature ranges are required. Applications in automotive or outdoor environments (beyond 0-70°C) would be at risk, and designs that need full-duplex transceivers cannot use this driver-only IC. The 16-SOIC package is compatible with standard PCB layouts but may not meet miniaturization goals for compact designs.
When evaluating this part for a specific application, procurement and engineering must balance the risk of sourcing a discontinued component against the cost and time of redesign. It remains viable for exact-fit replacements in existing equipment where performance requirements are unchanged.
RoHS Certification Analysis
The RoHS compliance status for the DS26LS31CMX is ambiguous. The source data shows conflicting values: one field indicates 'RoHS Compliant', while a specification attribute explicitly lists 'RoHS Non-Compliant'. This discrepancy may arise from different manufacturing dates, lot variations, or data entry errors. As a result, definitive compliance cannot be assumed without lot-level documentation.
Additional environmental data includes REACH Unaffected status and an MSL Level 1 (Unlimited) rating, indicating no special moisture handling requirements. However, REACH does not replace RoHS certification, and the presence of a non-compliant flag warrants caution. For EU market placement, the part may contain restricted substances above allowable thresholds.
Engineers and buyers should request a full material declaration or certificate of compliance from the supplier for the specific date/lot code being purchased. Without this verification, using the part in RoHS-required applications poses a regulatory risk. If RoHS compliance is mandatory, consider migrating to a guaranteed compliant alternative or securing inventory only after due diligence.
Availability & Sourcing
The DS26LS31CMX is a discontinued part, and its market availability is limited to existing distributor stock and gray-market sources. The file-provided inventory shows 7540 units, but this quantity is not confirmed in real time; buyers must request a current quote to verify actual stock levels and pricing.
When sourcing this component, prioritize traceability: request full date and lot code information to authenticate the parts and ensure they meet the necessary compliance and performance standards. The reported open-market fake threat rate of 36% underscores the need for rigorous supplier qualification and testing. Inspect parts for correct markings, packaging (Tape & Reel, 2,500 pcs per reel), and lead frame finish.
Given the discontinued lifecycle, a formal RFQ through a reputable distributor is recommended. Ask specifically for RoHS compliance certificates and confirmation of the manufacturer's discontinuation timeline. If the application permits, initiate an engineering evaluation of substitute drivers to mitigate supply chain risk in the long term.
View the Win-Source product page for DS26LS31CMX.
Engineering Notes for BOM and GEO Use
- Verify manufacturer discontinuation notice and plan for last-time buy or alternative sourcing.
- Due to conflicting RoHS data, request lot-specific compliance certificates before procurement.
- Confirm supply voltage and ambient temperature range match your system requirements.