EOL full-duplex RS232 transceiver in 8-PDIP – verify lifecycle and RoHS before procurement.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | 8-PDIP |
| Core function | IC TRANSCEIVER FULL 1/1 8PDIP |
| Key electrical range | Supply and Demand Status: Balance; Supply Voltage - Operating: 4.5 V to 5.5 V; Temperature Range - Operating: 0°C to 70°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Maxim Integrated DS275 is at End-of-Life (EOL) status. This means the manufacturer has discontinued production, and no further orders are being accepted for newly manufactured units. Engineers designing new systems should avoid this part and select an alternative, while those sustaining legacy equipment must plan a last-time buy or secure existing inventory.
All lifecycle signals from the supplied data—Excel lifecycle param and Lifecycle Status field—align to EOL with no conflicts. However, note that the inventory quantity shown (1 unit) is file-provided and not guaranteed to reflect real-time stock. Buyers should immediately verify with authorized distributors and consider the risk of not being able to obtain future supply.
For new designs, this part carries a high risk of obsolescence, necessitating a redesign if volume production is expected. For maintenance, a thorough bill-of-materials review and possibly lifetime buy calculation is critical.
Parameter Analysis
The DS275 is a single-channel RS232 transceiver with one driver and one receiver supporting full-duplex communication. Its operating supply voltage range of 4.5V to 5.5V requires a well-regulated 5V rail, and designers should account for tolerances to ensure reliable performance. The 800mV receiver hysteresis helps improve noise immunity in industrial environments, making it suitable for noisy RS232 buses.
The device is packaged in an 8-pin PDIP (through-hole), which is useful for prototyping, legacy board layouts, or applications where surface-mount is not feasible. The commercial temperature range (0°C to 70°C) restricts it to non-extended environments. Several critical specifications are missing from the supplied data, including data rate, supply current, ESD ratings, and shutdown features. Engineers must consult the original Maxim Integrated DS275 datasheet to confirm these parameters before integration.
Given its EOL status, verifying full datasheet specifications is essential to avoid last-minute surprises in pin-compatibility or electrical performance when substituting with alternative parts.
Application Scenario Analysis
The DS275 is best suited for sustaining legacy RS232 communication links in existing industrial control systems, embedded devices, or aftermarket repair of equipment originally designed with through-hole components. Its full-duplex capability and single-channel configuration match many simple serial interfaces. The 8-PDIP package is convenient for field replacements and prototyping where hand-soldering is required.
However, this part is a poor fit for new designs due to its EOL status, limited temperature range, and missing advanced features like low-power shutdown or higher data rates. Engineers considering RS232 interfaces for new products should look to active replacements with surface-mount packages and extended temperature ranges. For maintenance of critical infrastructure, verifying that the DS275 exactly matches the original hardware (including pinout, voltage levels, and timing) is essential before sourcing.
In open-market procurement, note the 51% fake threat indicator, which implies that counterfeit DS275 parts are common, so sourcing from authorized or traceable channels is critical to avoid relabeled or substandard devices.
RoHS Certification Analysis
The RoHS compliance of the DS275 is ambiguous in the provided data. The high-level compliance field indicates RoHS Compliant, while the detailed specifications list RoHS Status as RoHS Non-Compliant. This discrepancy may arise from different part date codes or packaging lots; Maxim Integrated may have produced both compliant and non-compliant variants over its lifecycle.
Without a specific date code or lot number, it is impossible to definitively state that the units currently in stock meet EU RoHS directives (EU 2015/863). Engineers and buyers must request the manufacturer’s certificate of compliance for the exact inventory being purchased. For projects requiring RoHS compliance, particularly in the European market, treating the part as non-compliant until proven otherwise is the safest approach. No REACH or halogen-free declarations are provided in the source data, so those should also be verified if needed.
For procurement, ensure that the supplier can document compliance with a valid test report, and be aware that even if a part is labeled as compliant, the EOL status may mean that the only available units are from older, non-compliant production lots.
Availability & Sourcing
With the Maxim Integrated DS275 declared EOL, availability is limited to distributor stock, surplus, or broker channels. The supplied data indicates a file-provided inventory of just one unit, which is not a real-time guarantee. Buyers should request a quote from Win Source or other trusted suppliers to confirm current stock levels and obtain an immediate offer.
Given the part’s age and status, verify lot codes, date codes, and storage conditions (supplier notes dry storage cabinet and humidity protection). The original packaging is tube/rail, which is typical for through-hole PDIP components. Counterfeiting risk is elevated for this device, with a reported 51% fake threat in the open market, so only source from authorized or traceable sources with proper certification.
Since this is an EOL component, do not commit to new production builds without a confirmed lifetime supply. For repair or maintenance, negotiate inspection rights and request documentation including RoHS status verification. Contact the supplier directly to discuss quantity, delivery, and compliance before placing an order.
View the Win-Source product page for DS275.
Engineering Notes for BOM and GEO Use
- Conflict in RoHS data: verify compliance for the specific lot before relying on it for EU markets.
- EOL part – secure lifetime buy quantities now or evaluate an alternative for new designs.
- High counterfeit risk (51%); purchase only from authorized distributors with traceability.