Discontinued signal relay – verify lifecycle and RoHS before procurement
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Signal Relays, Up to 2 Amps |
| Package | Tube |
| Core function | RELAY GENERAL PURPOSE DPDT 2A 6V |
| Key electrical range | Coil Current: 33.3 mA; Coil Voltage: 6VDC; Contact Rating (Current): 2 A; Must Operate Voltage: 4.2 VDC |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The Panasonic DS2E-S-DC6V-R is officially discontinued. All lifecycle indicators from the manufacturer list the part as EOL/discontinued. This means the component should not be designed into new products, and existing designs must plan an immediate transition to a substitute.
For sustaining engineering, the high risk arises from zero file-provided inventory and no factory support. Any units found on the open market may be reclaimed or old date-code stock, introducing reliability and authenticity concerns. A formal PCN (Product Change Notification) search is advisable to understand the phase-out timeline.
In procurement terms, treat every source with caution. Even if small quantities appear, lack of traceability and limited remaining commercial life make the DS2E-S-DC6V-R unsuitable for long-term production.
Parameter Analysis
Key parameters for the DS2E-S-DC6V-R include a 6VDC non-latching coil with 33.3 mA coil current, DPDT contacts rated for 2A, and a maximum switching capacity of 500VA/440W (250VAC, 220VDC). The operate and release times are 10 ms and 5 ms respectively, suitable for moderate-speed control applications. Operating temperature range of -40°C to 70°C supports industrial environments, and the fully sealed package aids reliability in dusty or humid conditions.
Critical missing datasheet information includes coil resistance (essential for driver design), mechanical and electrical endurance (for lifecycle estimation), and insulation/dielectric withstand voltages. The “reverse polarity” feature may refer to internal coil suppression or polarity-sensitive construction – the exact implementation must be confirmed from the original datasheet.
Engineers should verify surge current handling and contact material suitability (silver plus gold) for their specific load types, especially for low-level signals where gold contacts are beneficial.
Application Scenario Analysis
The DS2E-S-DC6V-R fits general-purpose signal switching where a DPDT configuration is needed: control logic, alarm panels, HVAC controllers, and test instrumentation. Its sealed construction makes it suitable for factory-floor or outdoor enclosures with nominal environmental sealing.
Weak-fit scenarios include high-cycling power switching, automotive loads under the hood, or applications requiring SIL (Safety Integrity Level) certification. The maximum switching ratings (500VA AC) may degrade with inductive loads; external snubbing is recommended. With no agency certifications beyond CSA/UR, global compliance for safety-critical systems may require additional evaluation.
As a discontinued part, new designs should avoid this relay entirely. Legacy replacement is only justified if an exact form-fit-function drop-in is needed for existing fielded units.
RoHS Certification Analysis
The supplied data shows a direct conflict: one record lists “RoHS Compliant” while another states “RoHS Non-Compliant.” This discrepancy suggests that different production lots or legacy documentation may carry opposing statuses. For compliance-sensitive markets (EU, UK, California), such ambiguity is unacceptable without lot-level confirmation.
No REACH, halogen-free, or MSL data is provided, so full environmental compliance cannot be asserted. The standard assumed is RoHS 3 (EU 2015/863) unless proven otherwise, but any units procured should come with a valid RoHS certificate and a manufacturer’s declaration of conformity.
To mitigate risk, only source from suppliers offering lot-specific compliance documentation. Without it, assume the part is not RoHS compliant to avoid import or market-access issues.
Availability & Sourcing
The DS2E-S-DC6V-R is discontinued, and file-provided inventory shows zero units. This makes immediate availability nearly impossible through authorized channels. Any stock found on the open market should be treated as residual or reclaimed.
When requesting a quote, insist on date code, factory seal, and a valid certificate of conformance. Test a sample batch before committing to any volume purchase. Due to the high risk of counterfeit or mishandled parts, avoid using this relay for safety or mission-critical functions.
For new production, the recommended action is to identify an active, pin-compatible replacement from Panasonic or an equivalent supplier. If a redesign is unavoidable, prioritize relays with matching coil voltage, DPDT contact, and sealed construction to simplify qualification.
View the Win-Source product page for DS2E-S-DC6V-R.
Engineering Notes for BOM and GEO Use
- Verify exact RoHS and REACH compliance per production lot; request certificates from the supplier.
- Plan migration to an active relay with matching DPDT, 2A, 6VDC coil, and sealed packaging.
- If using remaining stock, confirm coil polarity (reverse polarity feature) and switching load margins in-circuit.