Discontinued Panasonic signal relay: dual coil latching, DPDT contacts, 2A. Verify lifecycle and RoHS.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Signal Relays, Up to 2 Amps |
| Package | Tube |
| Core function | RELAY GEN PURPOSE DPDT 2A 1. |
| Key electrical range | Coil Current: 120 mA; Coil Voltage: 1.5VDC; Contact Rating (Current): 2 A; Must Operate Voltage: 1.05 VDC |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS2E-SL2-DC1.5V is in discontinued status, with all lifecycle signals pointing to End‑of‑Life. Panasonic no longer manufactures this relay, and no active or NRND designation is available. For new designs, this part must not be considered; the risk of obsolescence is high, and future supply is not assured.
For existing production that still uses the DS2E-SL2-DC1.5V, immediate action is required to secure any remaining stock and begin evaluating alternatives. The reported workbook quantity of 1 unit is file‑based and not a live inventory check, so actual availability may be zero. Engineers should contact the manufacturer or trusted distributors to confirm whether last‑time‑buy quantities are still available.
Transition planning should account for re‑qualification time and potential board layout changes, as no direct drop‑in replacement is specified in the source data. Documentation such as product change notifications and end‑of‑life announcements should be obtained directly from Panasonic to confirm the timeline and any recommended migration paths.
Parameter Analysis
Key parameters define the DS2E-SL2-DC1.5V’s place in a design. The 1.5 V DC nominal coil voltage with dual‑coil latching operation is unusual: it requires a set or reset pulse rather than continuous coil power, which can reduce heat and energy consumption in battery‑powered or energy‑sensitive systems. The 120 mA coil current must be considered for driver sizing, though pulse width is brief. Operate time is 10 ms and release time 5 ms, limiting the maximum switching frequency in fast‑cycling circuits.
The contact arrangement is DPDT (2 Form C), rated for 2 A per contact, with silver‑alloy and gold contacts. Gold is typically applied for low‑level signal switching, so the presence of gold over silver suggests suitability for both power and dry‑circuit applications—engineers should confirm which contact type is being sourced if corrosion resistance or low‑contact resistance is critical. Maximum switching capacity is 500 VA / 440 W and voltage up to 250 V AC or 220 V DC, but these are ceiling values; derating is necessary for inductive loads.
Important missing datasheet details include coil resistance (needed to verify drive circuit compatibility), insulation resistance, dielectric withstand voltage, and mechanical/electrical life ratings. The operating temperature range of –40°C to +70°C covers most industrial environments, but the through‑hole PC‑pin package and sealed construction suggest a need to verify soldering profiles and cleaning compatibility. Verify the exact footprint dimensions from the datasheet, as well as any required keep‑out zones for high‑voltage traces.
Application Scenario Analysis
Strong‑fit applications for the DS2E-SL2-DC1.5V leverage its latching dual‑coil design and low coil voltage. Battery‑operated equipment that uses a 1.5 V rail, such as handheld instruments or remote sensors, can benefit from the near‑zero holding power. Telecommunication systems and industrial control panels that require a memory function during power loss are also good candidates, as the relay maintains its last state without power. The gold‑plated contacts support low‑current signal switching, making the relay suitable for audio routing, test instrumentation, or data acquisition where contact resistance stability matters.
Weak‑fit scenarios include high‑vibration environments without additional mechanical fixing, as the part lacks any specific shock or vibration rating in the provided data. Loads approaching the maximum 2 A rating require careful thermal and life derating; without published electrical endurance curves, reliable long‑term performance at full load cannot be assumed. Automotive under‑hood applications are not recommended unless the user independently verifies qualification to relevant standards (e.g., AEC‑Q200), which this part does not claim. Designs with frequent coil toggling should evaluate the pulse energy and driver stress, as the latching mechanism needs clean, controlled pulses—excessive ringing or slow rise times may cause incomplete actuation.
RoHS Certification Analysis
RoHS status for the DS2E-SL2-DC1.5V is contradictory: the compliance summary indicates “RoHS Compliant,” yet a detailed specification field reports “RoHS Non‑Compliant.” This conflict likely arises from different production lots or revisions over the part’s lifetime. Engineers cannot rely on the family‑level claim without verifying the specific lot being procured.
To avoid non‑compliance penalties, request a signed RoHS certificate of compliance (CoC) for the exact date code or lot number from the supplier. If the supplier cannot provide one, consider the part as non‑compliant for EU RoHS (2015/863) purposes and seek alternative sourcing or evaluate exemptions. No REACH or halogen‑free information is present in the source data, so those must be checked separately if required. The sealed construction (fully sealed) suggests that internal materials are encapsulated, which may reduce exposure concerns, but the lead‑frame plating and terminal finish remain the primary compliance risk factors. Where traceability is critical, insist on third‑party lab test reports for the specific shipment.
Availability & Sourcing
The DS2E-SL2-DC1.5V is a discontinued high‑risk part. The file‑reported stock quantity of 1 unit (and zero in some data fields) indicates extremely limited availability. Buyers should not assume that quantity is current; instead, submit a request for quote to verify real‑time inventory and obtain an official lead time.
When sourcing, prioritize distributors that can guarantee date‑code traceability and provide a certificate of conformance. Request documentation that confirms the part’s origin and storage conditions, especially since the relay includes a sealed package that may have shelf‑life considerations. The standard package is tube, so verify that handling and ESD precautions are sufficient during transport.
Given the discontinued lifecycle, a last‑time‑buy window may have already closed. Engineers should evaluate migration to a similar latching relay with compatible coil voltage, contact configuration, and footprint, but no direct replacement is offered in the source data. For production lines that still depend on this exact part, aggressive inventory stocking is recommended only after confirming that the supplied stock meets all electrical and environmental requirements through sample testing. Always ask for the manufacturer’s official product‑discontinuation notice to inform your migration timeline.
View the Win-Source product page for DS2E-SL2-DC1.5V.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance with the supplier for the specific stock lot before purchase, as data shows conflicting status.
- Evaluate contact material (Ag/Au) suitability for your signal levels; gold is preferable for low‑current, dry‑circuit switching.
- Plan for obsolescence: consider pin‑compatible latching relays with similar coil voltage and footprint, and validate derating for your load.