Discontinued feed-through terminal block for DIN rail, 10-22AWG, screw terminals, 2 positions, blue.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | DIN Rail Channel |
| Package | Bulk |
| Core function | CONN TERM BLK FEED THRU 10-22AWG |
| Key electrical range | Current - IEC: 32 A; Current - UL: 30 A; Voltage - IEC: 1000V; Voltage - UL: 600V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Eaton Bussmann DS30-BU is officially discontinued, with multiple lifecycle signals indicating end-of-life (EOL). This status means the part is no longer in active production, and manufacturer support may be limited. For new designs, this component should not be considered due to high risk of supply chain disruption.
For existing systems that rely on the DS30-BU, it may still be sourced through remaining distributor inventory or on the secondary market, but availability is unpredictable. The file-based stock quantity of 1 unit is a snapshot and must be verified with suppliers in real time.
Engineers should evaluate migration paths to an active equivalent from Eaton Bussmann or a compatible supplier. If continued use is necessary, secure last-time-buy quantities and validate any lifecycle reclassification directly with the manufacturer. Do not use this part in new production without explicit manufacturer confirmation of continued support.
Parameter Analysis
Key parameters for the DS30-BU include its 10-22 AWG wire range (0.5–4 mm²) and dual current ratings: 32 A per IEC and 30 A per UL. The IEC voltage rating is 1000 V, while UL is 600 V. These values define the safe operating envelope for power distribution and control circuits. The 6.1 mm terminal width allows dense DIN rail packing, and the 2‑position feed‑through design supports simple loop wiring.
Screw terminals provide secure field connections but require proper torque to avoid loosening or conductor damage—a detail not specified in the available data. The blue color aids visual identification in multi‑color panel layouts. The bulk packaging suggests the part was intended for industrial panel building.
Missing datasheet values that must be verified before integration include insulation material, flammability rating (e.g., UL 94 V‑0), operating temperature range, torque specification, and any additional agency approvals (CSA, VDE). These impact regulatory compliance and long‑term reliability.
Application Scenario Analysis
The DS30-BU is designed for industrial control panels and power distribution where feed‑through DIN rail terminal blocks are required. Its 10‑22 AWG range makes it suitable for signal and low‑power circuits, and the 1000 V IEC rating allows use in higher‑voltage industrial environments.
Typical strong‑fit applications include retrofitting legacy machinery, maintenance repairs, and sustaining existing installations where the DS30-BU was originally specified. Because the part is discontinued, using it in new designs is a weak fit; there are no guarantees of long‑term supply.
In applications demanding RoHS compliance, the conflicting status data requires careful verification per lot. The part may not meet current EU directives, restricting its use in new products sold in RoHS‑regulated markets. For replacement projects, source only after confirming compliance documentation from the supplier.
RoHS Certification Analysis
The available RoHS information is contradictory. One source indicates RoHS Compliant, while the component specifications list RoHS Non‑Compliant. This discrepancy likely stems from different data entry points or legacy reporting. For a discontinued part, such conflicts are common.
No REACH, lead‑free, halogen‑free, or MSL data is provided. Without a clear manufacturer declaration, the DS30-BU cannot be assumed to meet EU RoHS (2015/863) or any other environmental standard. Lot‑level testing or certification from the supplier is required.
For procurement in regulated markets, treat this part as potentially non‑compliant and request explicit RoHS certificates along with test reports. If compliance cannot be confirmed, an alternative active terminal block with verified RoHS status should be sourced.
Availability & Sourcing
As a discontinued part, DS30-BU availability is extremely limited. The file‑based inventory shows only 1 unit, but this is not a real‑time guarantee. Buyers should request a quote for current stock and prepare for possible long lead times or no stock.
Standard packaging is bulk, but verify with the distributor. Traceability documentation (date codes, lot codes) is essential to confirm authenticity and storage conditions. For legacy system support, secure any available inventory after verifying lifecycle and compliance with the manufacturer.
Before committing to procurement, request RoHS certification and confirmation of discontinued status from Eaton Bussmann. Because this part is not recommended for new designs, evaluate active alternatives from the manufacturer to reduce supply risk.
View the Win-Source product page for DS30-BU.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance on a per-lot basis due to conflicting data sources between compliance fields and specifications.
- Not recommended for new designs; confirm end-of-life status with Eaton Bussmann before procurement to avoid supply gaps.
- Ensure screw terminal torque settings align with the specified 0.5–4 mm² wire range for reliable and safe connections.