EOL hot swap controller; verify stock and lifecycle before new design.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | PMIC - Hot Swap Controllers |
| Package | 8-SOIC |
| Core function | IC HOT SWAP CTRLR GP 8SOIC |
| Key electrical range | Current - Output (Max): 4A; Operating Supply Current: 1.1mA; Supply and Demand Status: Balance; Supply Voltage - Operating: 9 V to 13.2 V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS4560LS-AR+ from Maxim Integrated is confirmed End-of-Life (EOL). All lifecycle signals in the provided data align: the status is marked EOL, and the part is designated Obsolete. This high-risk status means the component is not recommended for new designs. Engineers should only consider the DS4560LS-AR+ for sustaining existing production or repair needs where a direct replacement is unavailable.
For new projects, sourcing teams must evaluate alternate active hot swap controllers. If continued use is unavoidable, initiate a last-time buy order immediately and verify lead times with Maxim or authorized distributors. The file-provided inventory shows a single unit, which is not a reliable indicator of real-time availability. Request a current stock quote to assess actual supply.
Additionally, confirm end-of-life notifications and any recommended migration paths directly with Maxim Integrated to ensure a smooth transition. Prolonged reliance on an EOL part increases procurement risk, especially given the 41 percent fake threat rate in the open market.
Parameter Analysis
The DS4560LS-AR+ is a single-channel hot swap controller with an integrated switch, delivering up to 4A output. Its operating supply voltage range of 9V to 13.2V makes it suitable for nominal 12V systems. The wide temperature range of -40°C to 135°C supports industrial and rugged environments. Key programmable features include circuit breaker, current limit, and slew rate, allowing engineers to tailor inrush current and fault protection. Built-in protections like OVP, UVLO, and thermal limit enhance system safety.
Critical parameters for design-in include the output current limit and timing settings via the ILIM and TIMER pins. However, essential datasheet details such as on-resistance (RDS(on)), safe operating area (SOA) curves, and transient thermal impedance are not provided here. These must be obtained from the official Maxim datasheet to validate thermal margins and ensure reliable operation under worst-case conditions.
The 8-SOIC package with surface-mount mounting is standard; verify PCB footprint compatibility and consider thermal management if the controller operates near the 4A limit. Missing MSL rating and detailed packaging specs should also be confirmed for assembly processes.
Application Scenario Analysis
The DS4560LS-AR+ is designed for general-purpose hot swap applications, typically in 12V backplane or plug-in module systems. It enables safe insertion and removal of circuit boards without powering down the entire rack, making it useful in telecom, server, and industrial control equipment. The integrated switch and programmable current limit simplify design, while the OVP, UVLO, and thermal limit protect both the card and the backplane.
Given its EOL status, the DS4560LS-AR+ is no longer appropriate for new designs. It is best suited for maintaining legacy systems that already use this exact part, where a form, fit, and function equivalent is necessary. It may also be used in repair depots or for small-volume aftermarket support.
For applications requiring higher currents or lower voltage rails, this controller would not be ideal. Engineers should evaluate active alternatives that support up-to-date compliance and availability. If used, verify that the 4A rating and thermal protections are adequate for the intended load and that the operating temperature range aligns with the system's environmental profile.
RoHS Certification Analysis
The supplied data lists the DS4560LS-AR+ as 'RoHS Compliant,' indicating compliance with the European Union's Restriction of Hazardous Substances directive. However, the exact RoHS version or exemption details are not specified. This status typically applies to the component family, but for EOL parts, lot-level verification is crucial, especially if the inventory originates from older production runs.
Without documentation such as a certificate of compliance or material declaration, the RoHS status cannot be guaranteed for a specific batch. Sourcing teams should request the manufacturer's or distributor's RoHS certificate for the exact date/lot code before purchasing. Additionally, REACH and halogen-free information is not provided; if these are required for your market, request those documentation as well.
For EU market access, ensure the DS4560LS-AR+ meets RoHS 3 (EU 2015/863) standards, which may require verifying no restricted substances exceed thresholds. Given the part's EOL lifecycle, extra due diligence is necessary to avoid compliance gaps in end products.
Availability & Sourcing
The DS4560LS-AR+ is an EOL part with limited file-provided inventory of one unit, but actual stock may vary significantly. Sourcing teams should request a quote for current availability and lead time. The part ships in tube/rail packaging, with storage condition specified as dry storage cabinet and humidity protection packaging. This suggests moisture sensitivity may be a concern; confirm MSL and ensure proper handling during assembly.
Given the 41 percent fake threat rate in the open market for this part, authenticity verification is critical. Procure only from authorized or reputable suppliers, and insist on full traceability documentation, including date/lot codes and certificates of conformance. For EOL components, last-time buy orders should be placed promptly to secure any remaining factory stock, and migration plans to active alternatives should be underway for new or growing production volumes.
To obtain the DS4560LS-AR+, submit a request for quote with the exact part number and quantity needed. Provide any compliance requirements, such as RoHS certificates or MSDS, to ensure the quoted material meets your standards. Be prepared for potential price premiums and limited supply, and avoid committing this part to new designs.
View the Win-Source product page for DS4560LS-AR+.
Engineering Notes for BOM and GEO Use
- Verify EOL status with Maxim and secure last-time buy inventory; plan migration to an active replacement.
- Confirm exact RoHS compliance certificate for the specific lot; request documentation when ordering.
- Assess application-specific derating: 4A max output, -40°C to 135°C range; consult datasheet for SOA and thermal curves.