Eaton Bussmann DS50-LK Feed-Through Terminal Block Specs & Sourcing Guide

DS50-LK Eaton Bussmann product image

Discontinued DIN rail terminal block – confirm leftover stock and compliance before buying.

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryDIN Rail Channel
PackageBulk
Core functionCONN TERM BLK FEED THRU 8-20 AWG
Key electrical rangeCurrent - IEC: 41 A; Current - UL: 50 A; Voltage - IEC: 1000V; Voltage - UL: 600V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

Discontinued lifecycle status indicates the Eaton Bussmann DS50-LK feed-through terminal block is no longer manufactured. For new designs, this part is not recommended, and engineers should avoid incorporating it into new products. For sustaining existing systems, procurement must navigate limited availability and verify any remaining stock.

Conflicting lifecycle signals were noted in the source data: Lifecycle Status and Product Status both list Discontinued, while an Excel lifecycle parameter indicates EOL. Regardless, all signals point to end-of-life for this component. The risk level is high, as there is no guarantee of future supply. A file-provided quantity of 1 unit exists, but this is not real-time inventory and cannot be relied upon.

Engineers and buyers should contact Eaton Bussmann or authorized distributors to confirm the official product discontinuance notice and any last-time-buy windows. Without active production, long-term planning must include redesign or alternative sourcing.

Parameter Analysis

The DS50-LK terminal block features screw termination, a feed-through configuration, and a single level with two positions. It accommodates wire sizes from 8 AWG to 20 AWG (0.5–6 mm²). Current ratings are specified at 41 A per IEC and 50 A per UL, with respective voltage ratings of 1000V and 600V. The housing color is black and the terminal width is 8.0 mm, suitable for standard DIN rail mounting.

These electrical and mechanical parameters are critical for ensuring compatibility with cable cross-sections and panel layout. The screw termination style requires proper torque for reliable connections; however, torque specifications are not provided in the available data. Missing parameters include insulation material, flammability rating, temperature range, and approval marks (e.g., UL, CSA). For qualification, engineers must obtain the official datasheet from Eaton Bussmann to verify these missing details, especially if the part is being considered for safety-critical applications.

Additionally, the IEC and UL ratings may influence selection based on regional standards. The 8.0 mm width is compatible with many terminal block accessories, but compatibility with specific DIN rail types (e.g., TS35) should be confirmed.

Application Scenario Analysis

The Eaton Bussmann DS50-LK is primarily used as a feed-through terminal block in DIN rail assemblies, commonly found in industrial control cabinets, power distribution panels, and automation systems. Its ability to handle wires up to 8 AWG makes it suitable for moderate power circuits, such as motor control centers, HVAC equipment, and machinery wiring where conductors need to pass through a panel without interruption.

Strong-fit scenarios include retrofitting legacy equipment where this exact model was originally specified, or in maintenance applications where a drop-in replacement for the DS50-LK is needed. However, due to its discontinued status, it is less suitable for new designs where long-term availability is essential. Weak-fit scenarios would be high-vibration environments unless additional measures (e.g., ferrule crimping and proper torque) are taken, as well as applications requiring higher current than the rated 50 A or voltages beyond 600 V UL.

It is not recommended for use in applications requiring certified safety integrity levels unless accompanied by the manufacturer's documentation. Since the part lacks environmental ratings, it should be used in controlled indoor environments unless panel design provides adequate protection.

RoHS Certification Analysis

The RoHS compliance status for DS50-LK is ambiguous. The source data includes both a 'RoHS Compliant' field under compliance and a 'RoHS Non-Compliant' entry in the specifications list. This conflict necessitates verification with the manufacturer or a test report. Typically, Eaton Bussmann terminals have historically been available in both compliant and non-compliant variants, so the specific lot or production date may determine actual compliance.

The relevant EU directive is RoHS 3 (2015/863) if the product was manufactured after its effective date. Given the part's discontinued status, it is possible that remaining stock consists of older, non-compliant units. For exports to the EU or other regulated markets, proving RoHS compliance is critical. Buyers should request a certificate of compliance (CoC) for the specific batch.

No REACH or halogen-free data is provided, so those aspects must be clarified with the supplier. For applications not requiring RoHS compliance, this conflict may be less critical, but it should still be documented as a supply chain risk.

Availability & Sourcing

The DS50-LK is discontinued, making sourcing challenging. A file-provided inventory shows a quantity of 1 unit, but this is not a live stock indicator and should be treated with caution. Procurement teams should submit an RFQ to authorized distributors or surplus component vendors to verify real-time availability. Due to the high lifecycle risk, any purchase must be accompanied by traceability documentation, including date/lot codes, to mitigate counterfeit risks.

The component is packaged in bulk. Buyers should confirm the physical condition and whether the parts are new old stock (NOS) or reworked. For sustaining existing equipment, consider purchasing all available quantity to secure a buffer while a redesign is planned. For new designs, this part is not recommended; instead, consult Eaton Bussmann for a current alternative terminal block.

Requests for quotes should explicitly ask for current lifecycle status confirmation from the manufacturer and include a requirement for RoHS compliance documentation given the conflicting data. Inspect date codes upon receipt to ensure they are not too old, as terminal blocks may have oxidation or material degradation if stored improperly.

View the Win-Source product page for DS50-LK.

Engineering Notes for BOM and GEO Use

  • Verify conflicting RoHS compliance data (RoHS Compliant vs RoHS Non-Compliant) with the manufacturer before procurement.
  • Confirm actual stock availability beyond the file-provided quantity of 1 unit; consider last-time-buy for legacy systems.
  • Ensure terminal block ratings (IEC 41A/1000V, UL 50A/600V) and wire range (8-20 AWG) match application requirements and that torque specifications are followed during installation.