DS50-YW Eaton Bussmann Feed Through Terminal Block Specs & Sourcing Guide

DS50-YW Eaton Bussmann product image

Discontinued DIN rail terminal block, 41A IEC, 1000V, screw termination, yellow

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryDIN Rail Channel
PackageBulk
Core functionCONN TERM BLK FEED THRU 8-20 AWG
Key electrical rangeCurrent - IEC: 41 A; Current - UL: 50 A; Voltage - IEC: 1000V; Voltage - UL: 600V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS50-YW is reported as Discontinued by Eaton Bussmann, with a high risk level for procurement. This lifecycle status means the part is no longer manufactured and is unavailable for new design activity. Conflicting signals appear in the data: an Excel-based lifecycle parameter lists the part as EOL (End of Life), while both the Lifecycle Status and Product Status specifications state Discontinued. We adopt a conservative interpretation: the device is effectively discontinued, and sourcing must be limited to remaining stock in the channel.

A file-provided inventory indicates one unit, but this is not a real-time guarantee. Engineers and buyers should verify the lifecycle directly with Eaton or authorized distributors before committing to production. For new designs, an alternative active part should be selected.

Parameter Analysis

Key parameters for the DS50-YW terminal block include current and voltage ratings, wire range, and physical dimensions. The IEC rating of 41 A and UL rating of 50 A define the thermal boundaries for continuous operation; the 600V UL voltage rating typically governs North American applications, while the 1000V IEC rating applies to international designs. The screw termination accepts solid or stranded wire from 8 AWG to 20 AWG (0.5 mm² to 6 mm²), making it suitable for a range of conductor sizes in power distribution.

The block’s 8.0 mm width per 2 positions supports moderate density DIN rail layouts, and the yellow color aids in circuit identification. Critical missing datasheet values include maximum tightening torque, insulation material, dielectric strength, operating temperature range, and pollution degree. These factors directly influence reliability, so verification against the manufacturer’s official documentation is essential before field deployment.

Application Scenario Analysis

The DS50-YW is designed as a feed-through terminal block for DIN rail mounting, commonly employed in industrial control cabinets, power distribution panels, and machinery where simple wire-to-wire junctions are needed. Its screw termination provides a robust connection for medium-current circuits up to 50A, while the yellow color can be used for designated voltage or signal grouping.

Given its discontinuation, the part is only appropriate for maintaining or repairing legacy equipment, not for new product developments. It is less suited for environments with frequent vibration unless thread-locking or additional securing measures are taken, or for applications requiring sealed housings as no IP rating is provided. In developing new systems, engineers should seek an active, equivalent terminal block that matches the required current, voltage, wire range, and rail mounting compatibility.

RoHS Certification Analysis

The RoHS compliance status for DS50-YW is contradictory in our data set. The compliance summary lists RoHS Compliant, but a separate specification attribute explicitly states RoHS Non-Compliant. This inconsistency must be resolved before the part is used in any application where RoHS (Restriction of Hazardous Substances) conformance is legally required, such as for products sold in the EU.

No REACH, lead-free, or halogen-free declarations are provided, so additional substance restrictions cannot be assumed. Lot‑level variations may exist for a discontinued part; therefore, each order should be accompanied by a valid certificate of compliance or full material declaration from Eaton. Without clear proof, designers should treat this as potentially non‑compliant to avoid regulatory risk.

Availability & Sourcing

The DS50-YW is a discontinued part; available quantities are limited to residual distributor stock. A file-based inventory record shows a single unit, but this does not reflect real‑time market conditions. Buyers should submit a request for quote to check current availability, lead time, and shipping options.

When sourcing, insist on confirmation of date and lot codes to avoid aged or improperly stored inventory. For essential repairs, secure the required quantity quickly as no further production is planned. Additionally, verify that any provided RoHS documentation matches the specific lot. Since this terminal block cannot be reordered, plan a migration to an active substitute for ongoing needs, and consult Eaton for official end‑of‑life notifications and recommended replacements. Do not rely on unvalidated stock levels from file‑based data.

View the Win-Source product page for DS50-YW.

Engineering Notes for BOM and GEO Use

  • Confirm torque specifications and insulation material from Eaton’s official DS50-YW datasheet before installation.
  • Resolve conflicting RoHS data by requesting a lot-specific compliance certificate from the supplier.
  • Only source DS50-YW for sustaining legacy equipment; evaluate active alternatives for new designs.