550W, 12V output, rack-mount front-end DC/DC converter for ITE commercial applications.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | ARTESYN / Advanced Energy |
| Category | DC DC Converters |
| Package | Bulk |
| Core function | DC/DC CONVERTER 12V 550W |
| Key electrical range | Current - Output (Max): 45A; Number of Outputs: 1; Power (Watts): 550W; Supply and Demand Status: Shortage |
| Workbook inventory signal | 8 pcs listed in the provided file |
Lifecycle Analysis
The DS550DC-3 is currently listed as Active by ARTESYN / Advanced Energy. This status indicates that the part is in full production and generally recommended for both new designs and sustaining production without imminent discontinuation risks. All lifecycle signals from the manufacturer and distributor sources align, reinforcing the stability of this product.
For procurement teams, an Active lifecycle means standard lead times and volume availability should be expected, but it remains prudent to verify the manufacturer's product roadmap periodically, especially for long-term programs. The file-provided inventory snapshot shows 8 units on hand, which is a limited quantity and not a real-time figure; thus, early demand planning is advised.
Engineers designing in the DS550DC-3 can proceed with confidence, but should secure a confirmed lifecycle statement from ARTESYN / Advanced Energy as part of their qualification package, particularly if the design will be in production for several years.
Parameter Analysis
Key parameters for the DS550DC-3 include its wide input voltage range of 36V to 75V, making it suitable for standard 48V telecom and data center power buses with margin for transients. The single 12V output can deliver up to 45A, providing 550W to downstream points-of-load or direct loads. The rated efficiency of 87% must be factored into system thermal design, as roughly 82W of heat will need to be managed at full load.
The rack-mount form factor (12.03 x 3.07 x 1.57 inches) and front-end type suggest this unit is meant for integration into standard 19-inch racks or dedicated power shelves, so mechanical clearance and airflow must be considered. Operating temperature range of -10°C to 50°C limits deployment to controlled environments; derating above 50°C is not specified and should be clarified. Critical missing parameters include input-output isolation voltage, output ripple and noise, load regulation, transient response, and protection features (overcurrent, overvoltage, overtemperature). Obtain the full datasheet to evaluate these before finalizing the design.
Application Scenario Analysis
The DS550DC-3 is specified for ITE (Information Technology Equipment) commercial applications, which typically encompass servers, storage systems, networking switches, and telecom infrastructure. Its front-end topology and rack-mount design make it especially appropriate for distributed power architectures in data centers, where a 48V bus is converted to 12V for motherboard regulation or other payloads.
In telecom central offices, the 36-75V input range directly matches -48V battery plant systems, and the high current output can feed multiple line cards or radio units. The unit is less suited for harsh industrial environments with wide temperature swings unless additional enclosure and cooling are provided, given the moderate 50°C maximum. It is also not intended for consumer or automotive applications due to its rack-mount form and commercial ITE safety certification scope. For applications requiring galvanic isolation between input and output, verify the isolation rating as this specification is not provided in the limited data set.
RoHS Certification Analysis
According to the supplied data, the DS550DC-3 is RoHS Compliant. This designation generally means it meets the substance restrictions under the EU RoHS Directive (2011/65/EU or the amended 2015/863). However, no specific directive version or detailed compliance documentation was included in the file.
For full material compliance assurance, particularly for products shipping into the EU, procurement should request a RoHS certificate of conformity from ARTESYN or the authorized distributor. Note that status provided by the manufacturer may be at the part family level, and individual lot-level compliance should be confirmed for production runs. Additionally, no REACH information is supplied; if required, verify REACH SVHC content separately. Integrators should ensure that subcomponents and soldering processes do not compromise the overall RoHS status of the end product.
Availability & Sourcing
The file-provided inventory shows a workbook quantity of 8 units for the DS550DC-3, and the supply-and-demand status is marked as 'Shortage'. This indicates that supply may be constrained, and immediate large-volume orders could face extended lead times. Since the part is in Active lifecycle, ongoing production should replenish stock, but procurement should closely monitor availability.
To source the DS550DC-3, request a quote that includes current stock levels, manufacturer lead times, and date/lot code traceability. Verify packaging (bulk) and request compliance documentation such as RoHS certificates and full datasheets. Given the shortage flag, early ordering and buffer stock planning are recommended. Contact an authorized distributor for the most accurate delivery schedules and to confirm lifecycle status before committing to production volumes.
View the Win-Source product page for DS550DC-3.
Engineering Notes for BOM and GEO Use
- Verify input voltage range (36-75V) and thermal derating curves for operation up to 50°C ambient prior to PCB layout and system integration.
- Check the actual efficiency at expected load points; 87% rated efficiency may vary, affecting heat dissipation in enclosed rack-mount installations.
- Confirm isolation voltage rating and transient response directly from the datasheet, as these critical parameters are not listed in the provided data.