High-Accuracy Analog Temperature Sensor with Wide -40°C to +125°C Range in 8-pin µMAX
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Moisture Sensors, Humidity |
| Package | UMAX |
| Core function | SENSOR ANALOG -40C-125C 8UMAX |
| Key electrical range | Max Supply Voltage: 5.5 V; Max Supply Voltage (DC): 5.5 V; Maximum Operating Temperature: 125 °C; Min Operating Temperature: -40 °C |
| Workbook inventory signal | 6000 pcs listed in the provided file |
Lifecycle Analysis
The DS600U+ is currently in Active lifecycle status according to Maxim Integrated. This status indicates the part is in full production, with continued manufacturer support for new designs and ongoing procurement. For new design projects, the Active status provides high confidence that the DS600U+ will remain available without immediate risk of obsolescence. However, engineers should periodically re-confirm the lifecycle status directly with the manufacturer, as product roadmaps can shift.
All available lifecycle signals, including the Excel lifecycle parameter and the component database lifecycle status, align on Active. No conflicting information was found. With low risk of discontinuation, the DS600U+ is suitable for both new product introduction and sustaining production.
Parameter Analysis
Key performance parameters of the DS600U+ define its suitability for precision temperature measurement. The sensor operates over an industrial temperature range of -40°C to +125°C, with an accuracy of ±0.5°C in the -20°C to 100°C range and ±0.75°C across the full span. Its analog voltage output provides a resolution of 6.45mV/°C, simplifying interfacing with microcontrollers or ADCs. The part operates on a supply voltage from 2.7V to 5.5V, with a low typical supply current of 140µA, which is advantageous for battery-powered or low-power designs.
The 8-pin UMAX (µMAX) surface-mount package measures 3.05mm x 3.05mm with a height of 0.95mm, enabling compact PCB layouts. Engineers should note that the output voltage offset at 0°C (listed as 400mV) must be verified from the official datasheet for accurate conversion. Missing datasheet details to confirm include output load driving capability, response time, and shutdown/standby mode current consumption. These parameters should be checked before committing to production.
Application Scenario Analysis
The DS600U+ is an analog temperature sensor, despite being categorized under Moisture Sensors, Humidity in some listings. Its primary application is in thermal monitoring and protection circuits where an analog voltage proportional to temperature is preferred. Strong-fit scenarios include industrial process control, HVAC systems, power supply thermal management, and embedded systems that require continuous temperature tracking with moderate accuracy.
Its low supply current (140µA) and wide voltage range also make it suitable for portable and battery-operated devices. However, it is not a humidity or moisture sensor; design teams relying on the category label must verify the actual function to avoid incorrect integration. Weak-fit scenarios are those demanding digital interfaces, multi-channel sensing, or very fast transient response, as these features are not supported by this analog single-channel device. Additionally, the part’s low popularity and shortage status suggest it may not be ideal for high-volume consumer products without risk assessment.
RoHS Certification Analysis
The DS600U+ is marked RoHS Compliant, and additional fields confirm Lead Free status and no REACH SVHC. This indicates compliance with the EU RoHS directive, likely RoHS 3 (2015/863), though the specific standard version is not explicitly stated. Buyers should request a compliance certificate for the specific lot to ensure consistency, as family-level declarations can sometimes mask part-level exceptions.
The component’s storage condition—dry storage cabinet with humidity protection packaging—suggests moisture sensitivity, so standard ESD and MSL handling procedures should be followed during assembly. While no explicit MSL rating is provided, the UMAX package likely follows JEDEC guidelines. For high-reliability applications, verify that the lead-free finish (e.g., matte tin) and halogen-free status meet project requirements.
Availability & Sourcing
Current file-provided inventory shows 6000 units of the DS600U+, but this figure is not a real-time guarantee, and the supply status is indicated as Shortage. Combined with a 47% fake threat probability in the open market, sourcing through authorized Maxim Integrated distributors is strongly recommended to avoid counterfeit or substandard parts.
For procurement, request a quote to confirm actual on-hand quantity, lead time, and lot traceability. Verify the lifecycle status as Active during ordering, and ensure RoHS and REACH certificates are included. The UMAX package should be shipped in sealed antistatic bags with desiccant to maintain dry storage conditions. Engineers and buyers should evaluate long-term availability given the shortage signal and low popularity, and consider alternate sources or buffer stock if the DS600U+ is critical to production.
View the Win-Source product page for DS600U+.
Engineering Notes for BOM and GEO Use
- Confirm the analog output transfer function and offset voltage from the datasheet for accurate temperature calculation.
- Follow dry storage and humidity protection guidelines during assembly to prevent moisture-related soldering defects.
- Source exclusively from authorized distributors to mitigate the 47% counterfeit risk and ensure component authenticity.