DS8923AN/NOPB RS-422/485 Transceiver Specs & Sourcing Guide

DS8923AN/NOPB Texas Instruments product image

Texas Instruments RS-422/485 Transceiver – 16-PDIP, RoHS Compliant

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategoryInterface - Drivers, Receivers, Transceivers
Package16-PDIP
Core functionIC TRANSCEIVER FULL 2/2 16PDIP
Key electrical rangeSupply and Demand Status: Balance; Supply Voltage - Operating: 4.5 V to 5.5 V; Temperature Range - Operating: 0°C to 70°C
Workbook inventory signal2267 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of DS8923AN/NOPB is officially unknown based on the supplied data. While the specifications include a field showing 'Status: Active,' no manufacturer lifecycle disclaimer, PCN, or EOL notice is present to confirm this. This conflict requires careful interpretation: a part may appear active in a distributor database while the original manufacturer has already moved it to NRND or last-time-buy.

For new designs, the absence of a verified active lifecycle means a medium risk of future supply interruptions. Engineers should treat DS8923AN/NOPB as potentially subject to NRND or discontinuation and avoid sole-source dependency. For sustaining production, existing stock may be adequate, but revalidation through TI’s product folder or direct inquiry is strongly recommended before committing to long-term procurement.

Given the uncertainty, any bill-of-materials planning should include a contingency for an alternative transceiver with similar RS-422/485 capability, especially if the design requires extended temperature ranges or surface-mount packaging.

Parameter Analysis

The DS8923AN/NOPB is configured as a full-duplex transceiver with two drivers and two receivers, making it suitable for point-to-point RS-422 links or four-wire RS-485 networks. The supply voltage range of 4.5 V to 5.5 V aligns with legacy 5 V logic systems, but designers must ensure the operating temperature of 0°C to 70°C meets system environmental requirements; industrial applications needing -40°C to +85°C should consider different part numbers.

Key electrical parameters include a receiver hysteresis of 70 mV, which enhances noise margin in electrically harsh environments. The 16-pin PDIP through-hole package simplifies prototyping but introduces mechanical constraints for high-density PCBs. The protocol support includes both RS-422 and RS-485, so the designer must set appropriate termination, biasing, and driver-enable logic based on the bus topology.

Important missing data that should be verified in the official datasheet: maximum data rate, driver output swing and current, receiver input impedance, propagation delay, and ESD ratings. Without these, qualification for high-speed or safety-critical applications is incomplete.

Application Scenario Analysis

The DS8923AN/NOPB is a strong fit for industrial automation interfaces that already use 5 V logic and require full-duplex RS-422 communication, such as PLC-to-HMI links, motor controller feedback, or CNC data streaming. Its 70 mV hysteresis and dual driver/receiver channels allow reliable data exchange over moderate distances (typically up to 10–50 meters at lower speeds).

In building automation or commercial RS-485 networks, this transceiver can be adapted for four-wire full-duplex multidrop setups, but it is not optimal for half-duplex two-wire systems where driver enable control is essential. The through-hole package is also well-suited for repair and maintenance of legacy equipment where surface-mount rework is not feasible.

Weak-fit scenarios include battery-powered or portable devices due to the 5 V-only supply and relatively high quiescent current typical of older transceivers. Designs requiring the extended industrial temperature range (-40°C to +85°C) or high data rates above 10 Mbps should verify against the datasheet or choose a newer transceiver family. The 0°C lower limit excludes outdoor or unheated installations.

RoHS Certification Analysis

The DS8923AN/NOPB is listed as RoHS Compliant, which is essential for import into regions enforcing the EU RoHS directive. However, the compliance standard is not detailed—whether it meets RoHS 2 (2011/65/EU) or the more restrictive RoHS 3 (2015/863) with additional phthalate restrictions is not specified. For CE marking or EU market access, obtaining the manufacturer’s declaration or test report for the specific production lot is recommended.

No REACH or halogen-free information is provided, so these additional environmental requirements must be checked separately with Texas Instruments. The through-hole lead finish is not disclosed; therefore, if the assembly process requires lead-free soldering, compatibility with the tin-lead or matte tin plating must be confirmed.

From a procurement standpoint, RoHS compliance should be verified at the lot level whenever possible. Distributors may ship stock from different lots, and family-level certifications may not guarantee compliance for every date code. Request a certificate of compliance (CoC) with each shipment to maintain audit readiness.

Availability & Sourcing

The DS8923AN/NOPB is available through multiple distribution channels, with a file-provided inventory figure of 2,267 units at the time of data collection. This quantity is not guaranteed in real time and should be validated by requesting a quote. The part is supplied in tube/rail packaging, with 25 pieces per tube, which is standard for through-hole devices and simplifies handling for manual assembly or small-batch production.

Given the unknown lifecycle and the 34% fake threat rating in the open market, sourcing from authorized Texas Instruments distributors or qualified independent distributors with robust anti-counterfeit processes is critical. Request date/lot code traceability, visual inspection, and if necessary, electrical testing for high-reliability applications. The storage condition recommendation of dry cabinet and humidity protection should be maintained before and during assembly.

For active production, secure inventory while verifying lifecycle status. If the part is confirmed NRND or last-time-buy, evaluate drop-in replacements from Texas Instruments or compatible RS-422/485 transceivers. For new designs, delay qualification until official lifecycle confirmation is received to avoid a premature design commitment.

View the Win-Source product page for DS8923AN/NOPB.

Engineering Notes for BOM and GEO Use

  • Verify lifecycle status with Texas Instruments before using DS8923AN/NOPB in new designs; conflicting 'Active' data creates procurement risk.
  • The 16-PDIP through-hole package suits prototyping or legacy designs but may not meet modern automated assembly requirements.
  • Ensure RS-422/485 bus termination and fail-safe biasing are implemented per system standard, especially in multi-node configurations.