Discontinued FPD-Link driver transceiver – verify lifecycle and compliance before sourcing.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | National Semiconductor (TI) |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | Tube |
| Core function | IC TRANSCEIVER 1/0 48TSSOP |
| Key electrical range | Voltage - Supply: 3V ~ 3.6V |
| Workbook inventory signal | 19000 pcs listed in the provided file |
Lifecycle Analysis
The DS90C365MTD is unequivocally discontinued. Multiple status indicators from the manufacturer confirm this, though one internal field lists EOL, creating a slight conflict. For procurement purposes, the conservative interpretation is that the part is no longer in active production and should not be considered for new designs.
Engineers maintaining legacy equipment may still source the DS90C365MTD, but they must first verify official end-of-life notices and last-time-buy dates from Texas Instruments. A file-provided inventory quantity of 19000 units is recorded, but this figure does not reflect real-time stock and may include mixed-date codes or non-compliant material. Without manufacturer support, long-term availability is uncertain, and any production commitment should be accompanied by a lifetime-buy analysis.
Parameter Analysis
The DS90C365MTD is categorized as a driver with 1 driver and 0 receivers, targeting unidirectional FPD-Link and LVDS signaling. Its supply voltage spans 3V to 3.6V, which is typical for LVDS applications but requires careful power sequencing and decoupling in mixed-voltage systems. The 48-TSSOP surface-mount package demands controlled PCB layout for impedance matching and low skew.
Critical datasheet parameters missing from the provided data include maximum data rate, propagation delay, operating temperature range, and ESD ratings. These directly affect signal integrity and reliability. Engineers must consult the original Texas Instruments DS90C365MTD datasheet to verify these values before integration. Additionally, the 1/0 driver/receiver count implies the device cannot be used in bidirectional or multi-drop configurations without external logic, limiting its use to simple point-to-point transmission.
Application Scenario Analysis
Strong-fit scenarios for the DS90C365MTD are legacy industrial or automotive display interfaces that already use FPD-Link or compatible LVDS standards, where a single-ended driver feeds a remote deserializer. Its role as a voltage-level shifter and driver aligns with flat-panel link video transmission in older control units or infotainment systems.
Weak-fit scenarios include new high-resolution designs requiring bidirectional communication, modern SerDes with embedded clock, or systems operating outside the 3V–3.6V supply range. The discontinuation status further discourages any new product development. For replacement or repair of existing equipment, the DS90C365MTD may still be viable if protocol and voltage requirements match, but designers should explore pin-compatible alternatives if long-term availability is needed.
RoHS Certification Analysis
RoHS compliance for the DS90C365MTD is ambiguous. The source data contains two conflicting entries: one field indicates RoHS compliance, while another explicitly states RoHS non-compliance. This contradiction likely arises from different production lots or packaging locations, where some batches may have been transitioned to lead-free finishes while others remain non-compliant.
Sourcing teams must treat the DS90C365MTD as potentially non-compliant until a valid certificate is obtained for the specific date code offered. REACH status is not provided in the available data and should also be verified if EU market access is required. Relying solely on manufacturer family-level declarations is risky; lot-level analytical reports (e.g., XRF) are recommended, especially given the open-market presence of this discontinued part.
Availability & Sourcing
The DS90C365MTD is available only through independent distributors and the open market, as Texas Instruments has discontinued the device. A file-provided stock quantity of 19000 pieces suggests some inventory exists, but buyers must request a formal quote to confirm real-time availability, date codes, and packaging—the standard package is tube, with 71 units per tube.
Traceability and authenticity are critical. With a reported counterfeit threat level of 33%, visual inspection, decapsulation testing, or authorized test house verification should be part of incoming QC. Since the part is discontinued, sourcing should include a review of end-of-life documentation and a plan for lifetime buys. Request a Certificate of Conformance and the manufacturer’s RoHS/REACH statement for the specific lot before payment.
View the Win-Source product page for DS90C365MTD.
Engineering Notes for BOM and GEO Use
- Verify end-of-life status directly with Texas Instruments before committing to production.
- Resolve RoHS compliance discrepancy by requesting lot-level certificates from the supplier.
- Ensure FPD-Link protocol compatibility and data rate match system requirements per datasheet.