DS90CR281MTDX TI Interface Specialized Specs & Sourcing Guide

DS90CR281MTDX Texas Instruments product image

Discontinued TI Interface IC – Verify Availability & Compliance

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategoryInterface - Specialized
PackageTape & Reel
Core functionIC INTERFACE SPECIALIZED 56TSSOP
Key electrical rangeVoltage - Supply: 4.5V ~ 5.5V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS90CR281MTDX from Texas Instruments is officially listed as Discontinued, with multiple lifecycle signals indicating end-of-life (EOL) status. Although minor discrepancies exist between 'EOL' and 'Discontinued' notations, the conservative interpretation is that this specialized interface IC is no longer recommended for new designs. Engineers should treat the part as high risk for procurement and avoid committing to it in new production programs.

For existing products that rely on the DS90CR281MTDX, immediate steps should be taken to secure remaining inventory. The file-provided quantity shows only a single unit, which is not a real-time guarantee. Buyers must verify actual stock levels through a quote request and confirm that the parts are authentic and meet required specifications.

Because the part is discontinued, Texas Instruments may have limited support and documentation. Obtain the last-time buy notice and any product change notifications directly from the manufacturer to assess the remaining support window and plan for a suitable migration path.

Parameter Analysis

Key parameters for the DS90CR281MTDX include its 4.5V to 5.5V supply voltage, surface‑mount 56‑TSSOP package, and MSL level 1 with unlimited floor life. The voltage range is typical for many logic and interface ICs, but designers must ensure that their system power rails can accommodate the required supply tolerance. The package footprint is a 0.240-inch wide TFSOP, and PCB layout must follow recommended land patterns to maintain signal integrity.

However, the provided data lacks critical technical specifications such as data rate, number of channels, input/output type, and temperature range. As a specialized interface IC, the DS90CR281MTDX likely implements a proprietary or industry‑standard protocol (e.g., Channel Link) that defines signal timing, jitter, and termination requirements. Without these details, it is impossible to fully assess fit for a particular design.

Engineers must consult the official Texas Instruments datasheet for the DS90CR281MTDX to obtain complete electrical characteristics, timing diagrams, and application guidance. Pay special attention to maximum operating frequency, ESD ratings, and power dissipation, as these directly influence reliability and qualification in industrial or high‑speed applications.

Application Scenario Analysis

Based on its classification as an Interface – Specialized IC, the DS90CR281MTDX is typically employed in systems that require high‑speed parallel data transmission. The part number suggests it may be part of Texas Instruments’ Channel Link series, commonly used in video cameras, flat‑panel displays, and other high‑bandwidth imaging applications. In such roles, it would serve as a serializer or deserializer to reduce the number of wires or PCB traces.

The device is a strong fit for applications that already depend on the DS90CR281 ecosystem, such as legacy industrial cameras or medical display interfaces. However, for modern designs that demand higher data rates or lower supply voltages, the 5V operation of the DS90CR281MTDX may be a limitation. It is not well suited for low‑speed GPIO expansion or level shifting, where simpler and more power‑efficient solutions exist.

Given the discontinued status, any new system architecture should avoid relying on this part unless absolutely necessary for backward compatibility with existing fielded hardware. When used in sustaining efforts, thorough testing is required to ensure it meets the exact timing and signal integrity needs of the application.

RoHS Certification Analysis

The RoHS status of the DS90CR281MTDX is ambiguous. The compliance summary states the part is RoHS Compliant, but a detailed specification field lists it as RoHS Non‑Compliant. This contradiction creates uncertainty for projects that must meet EU RoHS or similar environmental regulations. A final determination cannot be made from the available data alone.

Additionally, the part carries a REACH Unaffected status, which is a separate regulation and does not substitute for RoHS certification. The MSL rating is 1 (Unlimited), indicating no special moisture handling is required, but this does not relate to RoHS.

To resolve the RoHS question, request a full material declaration or Certificate of Compliance from Texas Instruments or an authorized distributor for the specific lot of DS90CR281MTDX parts you intend to purchase. Do not rely on aggregate compliance databases, as the conflict suggests possible variation between production batches.

Availability & Sourcing

Procurement of the DS90CR281MTDX is challenging due to its discontinued status. The file‑based inventory shows only a single unit, and this figure should not be considered a real‑time reflection of available stock. Additionally, the open market for this part carries a 31% counterfeit threat, making unauthorized sources highly risky.

To source this Texas Instruments specialized interface IC, submit a formal RFQ through authorized channels and explicitly request lot‑ and date‑code information. Verify the lifecycle status with the manufacturer before committing to a purchase. If the part is genuinely discontinued, no further production is planned, so any available inventory is finite.

For new designs, engineering teams should immediately begin evaluating active alternatives from Texas Instruments or other vendors. If the DS90CR281MTDX is required for sustaining production, secure inventory now and implement incoming inspection procedures that include X‑ray or electrical testing to screen for counterfeit devices. Always obtain compliance documentation for each shipment to confirm RoHS and other certifications.

View the Win-Source product page for DS90CR281MTDX.

Engineering Notes for BOM and GEO Use

  • Verify authenticity: open market threat for DS90CR281MTDX is 31%, so source only from trusted suppliers and test incoming parts.
  • Resolve RoHS conflict: obtain manufacturer’s lot‑specific compliance certificate to confirm EU RoHS adherence.
  • Plan migration: for new designs, switch to active alternatives; for existing products, secure last‑time buys and validate drop‑in replacements.