EOL specialized interface IC from Texas Instruments; verify lifecycle and stock before new designs.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Specialized |
| Package | 56-TSSOP |
| Core function | IC INTERFACE SPECIALIZED 56TSSOP |
| Key electrical range | Operating Supply Voltage: 4.75 V ~ 5.25 V; Supply and Demand Status: Limited |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS90CR284MTD/NOPB from Texas Instruments has been confirmed as End-of-Life (EOL) according to all available lifecycle signals, with an estimated EOL date marked as obsolete. This status carries a high risk for new designs, as no further factory support, mask-set revisions, or ongoing qualification can be expected. Engineers should not use this part in new products and must immediately plan for a last-time buy or migration to an alternative solution.
For sustaining production, existing inventory is finite and file-provided stock quantities are small and not guaranteed real-time. The part was introduced in July 1997, indicating a long production run now concluded. Any remaining stock should be secured quickly after verifying date-code freshness and authentic lot traceability.
Given the EOL classification, procurement teams should consult the manufacturer’s official PCN and EOL notice to confirm the exact discontinuance timeline and any recommended replacement part numbers, though none are supplied in this guide. Without a direct substitute, careful engineering evaluation is required to qualify a new device.
Parameter Analysis
The DS90CR284MTD/NOPB is characterized by an operating supply voltage range of 4.75V to 5.25V, which demands a stable 5V rail with adequate decoupling and low ripple to maintain signal integrity. The package is a 56-TFSOP (0.240-inch width), a surface-mount device that requires careful PCB layout to manage trace impedance and thermal dissipation. This package size and pin count imply a moderately complex routing requirement, especially if integrated into dense board designs.
Critical parameters such as maximum data rate, number of channels, interface protocol, and signaling levels are not available in the supplied data. Engineers must obtain the original Texas Instruments datasheet to evaluate differential input swing, termination requirements, and timing characteristics. Without these, it is impossible to assess compatibility with existing system interfaces or to ensure proper signal quality.
Other key specification gaps include operating temperature range, ESD ratings, and current consumption. These are essential for thermal analysis and reliability prediction. Until the full datasheet is reviewed, any integration effort carries risk, particularly in extended-temperature or high-reliability applications.
Application Scenario Analysis
Historically, specialized interface ICs like the DS90CR284MTD/NOPB have been employed in applications requiring high-speed serial data transmission, such as flat-panel displays, LCD timing controllers, digital video links, and automotive navigation systems. Its 5V operation and LVDS architecture suggest it may have been used to translate parallel RGB data into a serialized stream for reduced cable clutter and improved EMI performance.
Given its EOL status, however, this part is a strong fit only for legacy system maintenance, repair, and retrofits where a direct board-level drop-in is required. It is a weak fit for any new product development due to lifecycle risk and the absence of long-term availability guarantees. Designers should consider modern alternatives that offer lower supply voltages, higher data rates, and wider temperature ranges.
Engineers working on military or industrial upgrades that originally used this part must verify form-fit-function replacements carefully, as pin-compatible devices may not exist. The specialized nature of the IC means redesigns could involve significant system-level changes, so careful assessment of the entire signal chain is needed.
RoHS Certification Analysis
The DS90CR284MTD/NOPB is listed as RoHS Compliant, indicating adherence to the European Union’s Restriction of Hazardous Substances directive, likely RoHS 3 (EU 2015/863) given its historical active period. No specific exemptions are provided in the data, so compliance is assumed at the part level, but lot-level certification may differ and should be requested from the distributor.
While RoHS compliance is confirmed, no REACH or halogen-free declarations are included in the provided attributes. REACH certification is a separate regulatory requirement covering substances of very high concern; it is not a substitute for RoHS. For full environmental compliance, especially if shipping to European markets, purchasers should verify REACH status with the supplier and obtain a certificate of conformance.
Given the EOL nature of the part, some residual non-RoHS inventory could exist in the open market. It is critical to check date codes and request a compliance declaration for each lot to ensure that early-production units, which may have been manufactured before RoHS enforcement, are not mistakenly procured. Verification with the manufacturer’s official documentation remains the safest approach.
Availability & Sourcing
Availability of the DS90CR284MTD/NOPB is extremely limited. The file-provided quantity is 1 unit, but this is not a real-time stock level and must be confirmed by requesting a quote. Because the part is EOL, no further production is planned, and all remaining inventory is from distributor stock or residual market channels.
Counterfeit risk is notably high, with a reported 61% fake threat in the open market. Sourcing from unauthorized or uncertified vendors greatly increases the chance of receiving substandard or non-functional parts. Buyers should demand full traceability, including original manufacturer date/lot codes, and consider using certified test services to verify authenticity upon receipt.
For critical production needs, secure available inventory immediately through an RFQ process and verify the lifecycle status directly with Texas Instruments. Ensure compliance documentation is provided for every shipment, and evaluate migration to an alternative part for future builds. Do not commit this EOL component to new designs without a well-defined last-time-buy strategy and a risk mitigation plan.
View the Win-Source product page for DS90CR284MTD/NOPB.
Engineering Notes for BOM and GEO Use
- DS90CR284MTD/NOPB is EOL; validate with Texas Instruments and plan a last-time buy or immediate migration for new designs.
- The 56-TSSOP package and 5V±5% supply require careful decoupling, power sequencing, and controlled-impedance PCB routing.
- Due to 61% counterfeit risk, source only through authorized channels with full traceability and lot-level compliance documentation.