EOL Interface - Specialized IC from Texas Instruments – Verify availability and compliance.

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategoryInterface - Specialized
Package64-NFBGA (8x8)
Core functionIC INTFACE SPECIALIZED 64NFBGA
Key electrical rangeOperating Supply Voltage: 3 V ~ 3.6 V; Supply and Demand Status: Limited
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DS90CR285SLC is categorized as End-of-Life (EOL) by Texas Instruments, with all provided lifecycle signals aligning. This part is designated Obsolete (EOL), making it unsuitable for new designs and introducing high risk for sustaining production. Engineers should immediately begin migrating to a recommended replacement, as no further production of this device is expected.

For existing programs, securing last-time-buy inventory is critical. The file-provided stock quantity is only 1 unit, and supply/demand status is "Limited." This scarcity, combined with a 66% fake threat in the open market, necessitates strict sourcing controls. Verify any available inventory directly with authorized distributors and request manufacturer revalidation of the part's status.

Documentation such as the formal EOL notice from Texas Instruments should be reviewed to confirm the final order date and last shipment date. Without active production, sustaining procurement requires careful planning to avoid production gaps.

Parameter Analysis

Key specified parameters for the DS90CR285SLC include an operating supply voltage range of 3 V to 3.6 V and a 64-ball NFBGA package with an 8x8 mm body. The device is surface-mount and supplied in tubes. As an Interface - Specialized IC, it serves a dedicated interface function, but the datasheet details—such as data rate, number of channels, input/output types, and temperature range—are not provided in the sourcing data.

The supply voltage range indicates compatibility with standard 3.3V logic rails, which is common in LVDS-based display or camera link applications. The BGA package requires controlled PCB land patterns and careful reflow profiling; the 0.8 mm ball pitch typically demands non-solder mask defined pads for reliability.

Missing critical parameters prevent full engineering evaluation. When verifying this part, obtain the official Texas Instruments DS90CR285SLC datasheet to confirm: maximum data rate per channel, jitter specifications, ESD ratings, and operating temperature grade. These are essential for signal integrity simulation and derating analysis in high-speed interface designs.

Application Scenario Analysis

The DS90CR285SLC is intended for specialized interface applications such as digital video transmission, display panel interfaces, or high-speed point-to-point communication. Its 3.3V operation and BGA packaging suggest use in compact, high-bandwidth systems, possibly in industrial, medical imaging, or automotive display modules (if temperature-qualified). Strong-fit scenarios include legacy designs that already use this part and require exact form/fit/function replacements for maintenance.

Weak-fit scenarios include new designs that demand active lifecycle parts, applications requiring wide temperature ranges or enhanced ESD protection without confirmation, or systems needing smaller, more readily available interface ICs. The part's EOL status makes it unsuitable for any new product development or applications with long production lifecycles.

Without the full datasheet, it is not possible to determine the specific interface protocol or electrical compliance (e.g., LVDS, RSDS). Verify the intended application against the manufacturer's original documentation to ensure compatibility before attempting to source limited remaining stock.

RoHS Certification Analysis

The RoHS status for the DS90CR285SLC is listed as "Request Verification," meaning compliance documentation is not available in the provided data. It is not confirmed whether this part meets EU RoHS (2011/65/EU and 2015/863), China RoHS, or other regional directives. Given that the part was introduced in 1999 and is now EOL, older stock may include pre-RoHS manufacturing lots.

Before procurement, especially for European Union or other regulated markets, obtain a valid certificate of compliance or test report from the supplier. The statement "Request Verification" indicates that the information must be sourced from the manufacturer or a qualified reseller on a lot-specific basis.

Note that REACH status is not provided; REACH compliance does not substitute for RoHS. If the end product must be CE marked, RoHS compliance is mandatory. The engineer should request lead-free and RoHS-exemption details for the specific date/lot code being purchased to ensure environmental compliance.

Availability & Sourcing

The DS90CR285SLC is an EOL component with extremely limited availability. The file-provided stock quantity is 1 unit, and supply/demand status is "Limited." With a fake threat probability of 66% in the open market, sourcing from unauthorized channels carries high counterfeit risk. Always insist on full traceability, date/lot code verification, and third-party testing when purchasing from non-franchised distributors.

For procurement, request a quote from Win Source or other brokers specifying the exact part number, desired quantity, and required compliance documentation (RoHS, Certificate of Conformance). Because the part is obsolete, expect that remaining inventory may be held by a few niche distributors and that pricing and availability can change rapidly.

Engineers should not rely on this part for new production builds. Instead, work with Texas Instruments to identify a recommended replacement or migrate to an active interface IC. For sustaining maintenance of existing equipment, secure sufficient last-time-buy stock and consider board redesign for the long term.

View the Win-Source product page for DS90CR285SLC.

Engineering Notes for BOM and GEO Use

  • Verify RoHS and REACH compliance per lot; manufacturer documentation is required for EU market access.
  • Obtain full TI datasheet to confirm data rate, temperature range, and signal integrity parameters before design-in.
  • Due to EOL status and 66% fake threat, source only through authorized or trusted channels with rigorous inspection.