3V-3.6V Interface IC, 56-TSSOP Package, Not for New Designs
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Specialized |
| Package | Tube |
| Core function | DS90CR286A +3. |
| Key electrical range | Voltage - Supply: 3V ~ 3.6V |
| Workbook inventory signal | 17979 pcs listed in the provided file |
Lifecycle Analysis
Texas Instruments' DS90CR286AMTD presents conflicting lifecycle signals. While certain database fields list the lifecycle status as Active, the official Product Status is Not For New Designs (NRND). This discrepancy necessitates a conservative procurement approach. For new design projects, the part should be treated as NRND, meaning Texas Instruments does not recommend its use in new applications and may phase out production over time.
Engineers designing new systems should evaluate alternative interface ICs from TI or other suppliers. For existing production lines, the part may still be available, but customers should verify current lifecycle status directly with Texas Instruments and plan for potential last-time-buy scenarios. The file-provided inventory quantity of 17,979 units is a snapshot and not a guarantee of real-time availability.
Given the medium risk level, maintaining a strategic buffer stock is advisable if this IC is critical to sustained production. Procurement teams should confirm stock and lead times with authorized distributors, and cross-reference TI's official product change notifications for the DS90CR286AMTD.
Parameter Analysis
The DS90CR286AMTD is specified with a supply voltage range of 3V to 3.6V, typical for 3.3V logic systems. This narrow range requires stable power supply design with adequate decoupling and possibly low-dropout regulation to maintain signal integrity. The part is housed in a 56-TFSOP package (0.240 inch, 6.10mm width), designated as 56-TSSOP, which is surface mount. The small outline package demands careful PCB layout to manage thermal dissipation and high-speed signal routing characteristic of interface ICs.
Moisture Sensitivity Level is 2, meaning the component has a floor life of 1 year after opening the dry pack, per J-STD-033. This must be observed during assembly to prevent popcorning during reflow. The available dataset lacks critical parameters such as maximum data rate, input/output logic types, number of channels, and timing specifications. Engineers must consult the official Texas Instruments datasheet for these details before design-in.
Additionally, note the 33% fake threat indicator in the open market; verification of electrical parameters through sample testing is recommended when sourcing from non-authorized channels.
Application Scenario Analysis
The DS90CR286AMTD, classified under Interface - Specialized, is typically employed in high-speed data transmission applications such as LVDS links. One strong-fit scenario is as a deserializer in 28-bit Channel Link applications for flat-panel displays or industrial cameras, where a 3.3V supply and compact 56-TSSOP package align with space-constrained designs. The rising-edge data transfer feature may suit synchronous parallel data recovery in video interfaces.
Another potential use is in point-to-point data communication in embedded systems requiring noise-immune differential signaling. However, without explicit temperature range or qualification standards in the provided data, its suitability for automotive or rugged industrial environments is uncertain. Engineers should verify operating temperature grades and reliability data from the manufacturer.
The part is not recommended for new designs in safety-critical systems without additional fault-tolerance analysis. For legacy display interface upgrades, it may serve as a maintenance solution. Given the NRND status, new designs should consider newer TI LVDS interface parts with better availability.
RoHS Certification Analysis
The DS90CR286AMTD is marked as RoHS Compliant, indicating adherence to the European Union's Restriction of Hazardous Substances directive. The standard typically met is EU RoHS (often referring to Directive 2011/65/EU and its amendments, including 2015/863). This means the component is free of the six restricted substances (lead, mercury, cadmium, hexavalent chromium, PBBs, and PBDEs) and the four added phthalates, within allowed limits.
Additionally, the REACH status is listed as 'REACH Unaffected', meaning no Substances of Very High Concern (SVHC) are present above the threshold, but REACH compliance is separate from RoHS and does not substitute for it. For procurement documentation, a Certificate of Compliance (CoC) should be requested from the distributor or manufacturer to validate lot-level RoHS adherence, especially when sourcing from non-authorized channels where counterfeit risk (33% fake threat) is a concern.
The Moisture Sensitivity Level (MSL) 2 rating does not directly affect RoHS but requires proper handling to ensure solderability and reliability in lead-free assembly processes.
Availability & Sourcing
Although the DS90CR286AMTD is classified as Not For New Designs by Texas Instruments, it may still be procured for sustaining production or repair needs. According to the provided file data, approximately 17,979 units are recorded in stock, but this figure is not a real-time guarantee and should be verified through a request for quote (RFQ). The component is supplied in tube packaging with a standard package quantity of 34 pieces per tube.
Given the 33% fake threat indicator in the open market, buyers should prioritize authorized Texas Instruments distributors or reputable suppliers like Win Source that offer traceability documentation, including date/lot codes and certificates of conformance. Before committing to a purchase for ongoing production, verify the exact lifecycle status with the manufacturer and inquire about last-time-buy plans and potential drop-in replacements.
For engineering teams, it is advisable to secure a one-time buy sufficient to cover a product’s remaining lifecycle if no redesign is planned. For new designs, source modern alternatives with an active product status. Request a quote to confirm current pricing, lead times, and available quantity, and ensure all compliance certifications (RoHS, REACH, MSL) accompany the shipment.
View the Win-Source product page for DS90CR286AMTD.
Engineering Notes for BOM and GEO Use
- Verify lifecycle status directly with Texas Instruments before committing to new production designs; NRND may lead to future availability constraints.
- Account for 33% fake threat in the open market by implementing rigorous incoming inspection and using authorized distribution channels.
- MSL Level 2 requires floor life tracking within 1 year after opening dry pack; follow J-STD-033 handling.