Quad LVDS transmitter, 400Mbps, 16-SOIC, EOL – verify lifecycle and source carefully
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | 16-SOIC |
| Core function | IC TRANSCEIVER 4/0 16SOIC |
| Key electrical range | Supply and Demand Status: Balance; Supply Voltage - Operating: 3 V to 3.6 V; Temperature Range - Operating: -40°C to 85°C |
| Workbook inventory signal | 4810 pcs listed in the provided file |
Lifecycle Analysis
The DS90LV047ATMX is designated End-of-Life (EOL) by Texas Instruments, carrying a high procurement risk. All internal lifecycle signals align on EOL, except one spec line that shows 'Status: Active'. This discrepancy is likely a data artifact; the multiple explicit EOL indicators must be treated as definitive. For new designs, this part should not be considered; the focus must shift to alternative LVDS drivers.
For sustaining production, engineering teams need to confirm the EOL notice directly with the manufacturer and assess last-time buy options. The file‑provided inventory quantity of 4810 pieces offers a snapshot but no real-time guarantee. Any decision to procure should be preceded by a revalidation of lifecycle status and an evaluation of migration paths to avoid production disruptions.
Parameter Analysis
Key parameters that directly impact electrical and thermal design include the LVDS protocol, 400 Mbps data rate, 3 V to 3.6 V supply voltage, and -40 °C to +85 °C operating temperature range. The 4‑driver/0‑receiver configuration confirms this is a transmitter only, not a transceiver, despite the brief description. The 16‑SOIC package and SMD mounting dictate standard reflow profiles and PCB footprint considerations.
Critical missing datasheet details—propagation delay, output voltage swing, common‑mode range, and rise/fall times—must be obtained from the official Texas Instruments datasheet before integration or requalification. These parameters influence signal integrity, timing margins, and interoperability with LVDS receivers. Engineers should also verify power‑supply sequencing requirements and ESD ratings, as neither is provided in the current specification set.
Application Scenario Analysis
The DS90LV047ATMX is a strong fit for point‑to‑point, unidirectional high‑speed data links in industrial automation, telecommunications, and automotive infotainment systems. Typical uses include clock distribution, flat‑panel display interfaces, and serial data transmission where LVDS noise immunity and low power are required. Its 3.3 V operation suits standard logic domains.
This part is a weak fit for applications needing bidirectional communication, because it integrates four drivers and no receivers. Similarly, designs requiring supply voltages below 3 V or data rates significantly beyond 400 Mbps should look elsewhere. Given the EOL status, the most practical use is in sustaining existing systems that already rely on this device; any new deployment should be avoided unless a validated replacement is unavailable and the project carries minimal risk.
RoHS Certification Analysis
The DS90LV047ATMX is listed as RoHS Compliant, but the specific directive version (e.g., RoHS 3, EU 2015/863) is not stated. As an EOL component, compliance may have been certified at the product family level rather than individual lot; for high‑reliability applications, request a lot‑specific certificate of conformance.
No REACH or halogen‑free declarations appear in the supplier data. Note that REACH compliance does not inherently satisfy RoHS requirements, so both must be verified independently if mandated by the end application. Given the age and EOL status, consider requesting updated material composition reports from the distributor.
Availability & Sourcing
As an EOL part, the DS90LV047ATMX is subject to constrained supply and heightened counterfeit risk—29% fake threat probability is noted in open‑market data. The file‑provided inventory shows 4810 units, but this is not a real‑time indicator. The part is packaged on a TR reel and requires dry storage with humidity protection.
To source the DS90LV047ATMX, submit a request for quote (RFQ) to authorized distributors and specify date/lot code requirements. Verify that lifecycle status remains EOL and request compliance documentation (RoHS, REACH if needed) per lot. For new production, this part is not recommended; instead focus on qualifying a replacement LVDS driver and securing samples early to avoid supply interruptions.
View the Win-Source product page for DS90LV047ATMX.
Engineering Notes for BOM and GEO Use
- Verify EOL status with Texas Instruments official notice; the presence of an 'Active' status in one data field suggests inconsistency, so rely on manufacturer’s definitive lifecycle documentation.
- Missing datasheet parameters such as propagation delay and differential output voltage swing must be confirmed before reusing the DS90LV047ATMX in existing designs.
- With a 29% fake threat rate in the open market, source only through authorized distributors and request full traceability, date/lot codes, and compliance certificates.